BLD-Final | 6/11/2004 | 6/11/2004 | 6/11/2004 | P | PASS |
Tom Arcoraci
|
|
|
ok for lc
|
Letter of compliance | | | 6/11/2004 | | DONE |
|
|
|
Letter of Compliance issued 6-11-04.
|
BLD-Final | 6/8/2004 | 6/10/2004 | 6/10/2004 | A | NR |
Tom Arcoraci
|
|
|
Scheduled by a contractor via Hello! on 6/8/2004 at 2:11:13 PM. Contact: ###-####. needs final letter from mti and blocking installed at tjis 6/10/2004 10:24:40 AM
|
BLD-Footing | 5/13/2004 | 5/13/2004 | 5/13/2004 | P | PART |
Tom Arcoraci
|
|
|
Scheduled by a contractor via Hello! on 5/13/2004 at 8:38:36 AM. Contact: ###-####. ok pending eng ok 5/13/2004 3:17:43 PM
|
Issue PAID IN FULL permit | | | 5/12/2004 | | |
|
|
|
|
Plan assigned to (DRS) | 5/5/2004 | 5/5/2004 | 5/11/2004 | | PASS |
Dan Stuart
|
|
|
5/11/2004 10:18:07 DRS - activity updated through activity BLDA022 from case BLD04-00954.
|
Routing - Erosion and Sediment | 5/7/2004 | | 5/11/2004 | | PASS |
|
|
|
ESC approved with conditions attached to plans.
|
Inspection Record Card- Bld | | | 5/11/2004 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 5/11/2004 | | DONE |
|
|
|
|
Telephone call | | | 5/11/2004 | | DONE |
|
|
|
permit ready and fee due
|
Routing - PLAN CHECK | 5/11/2004 | | 5/11/2004 | | PASS |
|
|
|
Approved as noted on the plans and attached plan review comments and TBL. 1704.5.1 for Special Inspection of Masonry.
|
Plan Review Completed(1st rev) | | | 5/11/2004 | | FAIL |
|
|
|
Failed in plan review. Masonry Pilasters shown on architectural plansat wrong spacing per submitted engineering. Also Special Inspection is required for Masonry. I have contacted Eric Wolfe, Pinnacle Eng. to verify requirements and left message for architect to call me on his phone messaging.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 5/11/2004 | | PASS |
|
|
|
To permit desk for issue.
|
Telephone call | | | 5/10/2004 | | DONE |
|
|
|
Phone conversation with Larry Sundell to discuss maximum spacing between centers of pilasters. Engineering indicated 13'-4" max. and architectural plan shows one spaced at 14'-9". I agreed to red-line this on the plan if Larry Sundell would verify the owner and contractor are notified of change. I also reviewed the special inspection requirements per my discussion with Eric Wolfe, engineer. I will make the note on the plan and attach a copy of Table 1704.5.1, Level 1 inspection requirements for masonry. Larry will help the owner obtain an approved Special Inspection agency through the Structural Inspector.
|
Routing - PLANNING | 5/7/2004 | | 5/7/2004 | | PASS |
|
|
|
Took plan to tempra based on previous discussion and she signed off on them.
|
Routing - PLAN CHECK | 5/5/2004 | | 5/7/2004 | | FAIL |
|
|
|
Corrections required. Copy of report faxed to architect.Pending approval by Planning & Errosion Sediment control & Planning.
|
Telephone call | | | 5/7/2004 | | DONE |
|
|
|
CALL TO ERIC WOLF, PINNACLE ENGINEERS, TO VERIFY REQUIREMENT FOR pILASTER SPACING OF 13'-4" O.C. MAX PER ENGINEERING VS. ARCHITECT SPACING OF 14'-9" FOR ONE LOCATION. NEEDS TO BE 13'-4".
|
Telephone call | | | 5/7/2004 | | DONE |
|
|
|
CALL TO ERIC WOLF CONCERNING SPECIAL INSPECTION REQUIREMENTS. DETERMINED SPECIAL INSPECTION TO BE BASED ON TABLE 1704.5.1, LEVEL 1 (NONESSENTIAL FACILITIES). I WILL ATTACH A COPY OF THE TABLE TO THE PLANS.
|
Telephone call | | | 5/7/2004 | | DONE |
|
|
|
CALL TO LARRY SUNDELL TO DISCUSS PLAN REVIEW CORRECTIONS / CLARIFICATIONS NEEDED. HE WAS NOT AVAILABLE SO I LEFT A VOICE MESSAGE TO CALL ME BACK. WILL FAX HIM COPY OF REPORT.
|
Plans ACCEPTED BY PLAN TECH | | | 5/5/2004 | | DONE |
|
|
|
|
Application received | | | 5/4/2004 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 5/4/2004 | | |
|
|
|
|
Fee Review-notes | 5/4/2004 | 5/4/2004 | | | |
|
|
|
|