BLD-Final | 11/29/2004 | 11/29/2004 | 11/29/2004 | P | PASS |
Lane Manuel
|
|
|
Justin; Phone #: ###-#### Internet Inspection Request from: Jan Rice
|
DOC - Permit Finaled | 11/29/2004 | 11/29/2004 | 11/29/2004 | P | PASS |
Lane Manuel
|
|
|
Finaled by inspector at 11/29/2004 3:19:54 PM
|
BLD-Final | 11/24/2004 | 11/26/2004 | 11/26/2004 | A | FAIL |
Jim Storey
|
|
|
rob sr; Phone #: ###-#### Internet Inspection Request from: Barbara Moore no access/b-vent to close to door astracal. 11/26/2004 9:46:14 AM
|
BLD-Final | 11/26/2004 | 11/26/2004 | 11/26/2004 | P | FAIL |
Jim Storey
|
|
|
Justin; Phone #: ###-#### Internet Inspection Request from: Jan Rice 6 inch clearance astrecal to b-vent. 11/26/2004 3:01:20 PM
|
BLD-Energy code compliance | 11/1/2004 | 11/2/2004 | 11/2/2004 | A | FAIL |
Troy James
|
|
|
Justin; Phone #: ###-#### Internet Inspection Request from: Jan Rice
Need to insulate at bay window second level, and install insulation behind corner and perpindicular wall cavities. 11/2/2004 9:12:45 AM
|
BLD-Energy code compliance | 11/2/2004 | 11/2/2004 | 11/2/2004 | A | PASS |
Troy James
|
|
|
|
BLD-Framing/Rough-in | 11/1/2004 | 11/1/2004 | 11/1/2004 | P | FAIL |
Troy James
|
|
|
Justin; Phone #: ###-#### Internet Inspection Request from: Jan Rice
actually energy inspection, not ready 11/1/2004 2:00:54 PM
|
BLD-Framing/Rough-in | 10/29/2004 | 10/29/2004 | 10/29/2004 | P | PASS |
Tom Arcoraci
|
|
|
justin; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
BLD-Wall cover | 10/25/2004 | 10/26/2004 | 10/26/2004 | A | PASS |
Jim Storey
|
|
|
garage; Phone #: ###-#### Internet Inspection Request from: Linda Hartwell
|
BLD-Foundation | 9/8/2004 | 9/9/2004 | 9/9/2004 | A | PASS |
Tom Arcoraci
|
|
|
jerry; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie wip ok 9/9/2004 9:12:05 AM
|
BLD-Footing | 9/8/2004 | 9/8/2004 | 9/8/2004 | P | PASS |
Jim Storey
|
|
|
jerry; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
BLD-Footing | 9/2/2004 | 9/2/2004 | 9/2/2004 | P | NR |
Jim Storey
|
|
|
dane; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
Issue PAID IN FULL permit | | | 9/1/2004 | | DONE |
|
|
|
|
Plan assigned to (DJO) | 8/3/2004 | 8/3/2004 | 8/3/2004 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 8/3/2004 | | DONE |
|
|
|
|
Plan Review Report | | | 8/3/2004 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 8/3/2004 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 8/3/2004 | | DONE |
|
|
|
|
Telephone call | | | 8/3/2004 | | DONE |
|
|
|
Spoke with Rob Sr and told him that permit is ready & fees///8/3/04 1:00pm BAM
|
Pending Assignment by DJO | 6/28/2004 | | 8/3/2004 | | DONE |
|
|
|
8/3/2004 08:29:09 DJO - activity updated through activity BLDA169 from case BLD04-01434.
|
Plans ACCEPTED BY PLAN CHECK | | | 8/3/2004 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/3/2004 | | DONE |
|
|
|
|
Routing - PUBLIC WORKS | 7/27/2004 | | 7/28/2004 | | PASS |
|
|
|
|
Routing - PLANNING | 7/21/2004 | | 7/27/2004 | | PASS |
|
|
|
needed clarification on specific lot to verify this was not a double fronted lot. Applicant did not provide a site specific site plan. Verified with Dave Abo.
|
Routing - PLANNING Land Div | 7/19/2004 | | 7/19/2004 | | PASS |
|
|
|
Lot 26, Block 5 of Kroegers 1st Ivywild
|
Routing - PLANNING Land Div | 6/30/2004 | | 6/30/2004 | | FAIL |
|
|
|
Need new tax parcel # and possible demo permit.
|
Application received | | | 6/28/2004 | | |
|
|
|
|
Routing - PLAN CHECK | 7/29/2004 | | | | |
|
|
|
|