Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD04-01910
StatusFinaled
Name SKIP JONES
Site Address 1381 W PARKHILL DR
Project Name 
Customer Number 
ePlanReviewNo
Description
To construct a 2087 sq. ft. one story single family dwelling with a 1174 sq. ft. unfinished basement, a 963 sq. ft. attached three car garage, a 117 sq. ft. covered entry way and 896 sq. ft. of covered deck per approved plans, all engineering/red-lining and attached condition list. Seperate permits will be required to finish basement. This lot is within a hillside area and is subject to the hillside ordinances. Class "A" roof system and 30 ft. defensible space shall be maintained. Unless otherwise approved by Boise City Fire Department, this structure shall be fitted with a 13D sprinkler system. This system shall be equipped with a alarm initiating device, commonly referred to as a flow switch, and will be connected to a audible outside alarm. PC #489 DJO
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/15/20059/16/20059/16/2005PPASS
DetailsMike Jordan
skip; Phone #: ###-#### Internet Inspection Request from: Barbara Moore. Recieved all required paper work.
DOC - Permit Finaled9/16/20059/16/20059/16/2005PPASS
DetailsMike Jordan
BLD-Grading Inspection9/15/20059/15/20059/15/2005 BOND
Rough grading is complete. Fine grading, revegetation of the slope on the south side of the lot, and placement of a berm at the top of the slope on the west side of the lot are not complete. For this the engineer has recommended a $1,000.00 bond. Upon receipt of this bond the grading and drainage is conditionally approved
BLD-Energy code compliance4/27/20054/28/20054/28/2005PPART
DetailsTony Young
skip- --call 1st before insp ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
need fireplace permit and inspections,,, ok to sheet rock un-affected areas 4/28/2005 12:30:12 PM
BLD-Energy code compliance4/26/20054/27/20054/27/2005PCANC
DetailsTony Young
skip- --call 1st before insp ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie 4/26/2005 12:31:26 PM
BLD-Framing/Rough-in4/25/20054/26/20054/26/2005APART
DetailsTony Young
skip- draft stops--call 1st before insp ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
BLD-Framing/Rough-in4/13/20054/13/20054/13/2005PFAIL
DetailsTroy James
###-#### - SKIP NOTE: please call 1/2 hr prior to inspection
need rough plumbing, drafstopping at duct chase, furred out walls in basement, energy seal done, approval from engineer on missing holddowns in basement exterior west wall, fireplace installed and inspected 4/13/2005 2:44:02 PM
BLD-Framing/Rough-in3/15/20053/16/20053/16/2005AFAIL
DetailsTroy James
Don-call before you go out ; Phone #: ###-#### Internet Inspection Request from: Jan Rice
need fix from designer for missed PHD22's at basement west wall, ok to cover exterior 3/16/2005 10:00:38 AM
BLD-Foundation12/17/200412/20/200412/20/2004APART
DetailsTony Young
Brent; Phone #: ###-#### Internet Inspection Request from: Jan Rice
stem walls and columns 12/20/2004 11:25:39 AM
BLD-Footing12/13/200412/14/200412/14/2004APART
DetailsTony Young
brent; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
upper ftgs, column ftgs, wing retaining wall ftgs,,, ok , pending confirmation of compaction papers from M. T. I. 12/14/2004 11:30:39 AM
BLD-Foundation11/9/200411/10/200411/10/2004APASS
DetailsTony Young
Brent-around 11:00 if possible-Foundation basement wall; Phone #: ###-#### Internet Inspection Request from: Cheryl Baumgartner
BLD-Footing11/1/200411/1/200411/1/2004PPART
DetailsTony Young
Skip ; Phone #: ###-#### Internet Inspection Request from: Jan Rice
wip 11/1/2004 2:28:18 PM
BLD-Grading Inspection10/27/200410/27/200410/27/2004 DONE
Footing subgrade approved by the geotechnical engineer
Issue PAID IN FULL permit  10/20/2004 DONE
Inspection Record Card- Bld  10/19/2004  
Case Summary (BLD)  10/18/2004 DONE
Telephone call  10/1/2004  
Called builder about the address change. AEM 10/1/04
Inspection Record Card- Bld  10/1/2004 DONE
Print Occupancy Form  10/1/2004 DONE
Permit Ready to Issue  9/29/2004 DONE
Inspection Record Card- Bld  9/29/2004 DONE
Print Occupancy Form  9/29/2004 DONE
Telephone call  9/29/2004 DONE
talked to skip & left him that the permit and fees are ready to be picked up 9/29/2004
Plan assigned to (DJO)9/28/20049/28/20049/28/2004 DONE
Plan Review Report  9/28/2004 DONE
Plans ACCEPTED BY PLAN CHECK  9/28/2004 DONE
PLANS/APPL TAKEN TO FRONT DESK  9/28/2004 DONE
Pending Assignment by DJO8/18/2004 9/28/2004 DONE
9/28/2004 11:55:19 DJO - activity updated through activity BLDA169 from case BLD04-01910.
Routing - PLAN CHECK9/24/2004 9/28/2004 PASS
Dan O.
Routing - PLANNING9/22/2004 9/23/2004 PASS
Approved as redlined.
Routing - Erosion and Sediment9/23/2004 9/23/2004 PASS
approved with attached conditions.
Routing - FIRE9/23/2004 9/23/2004 PASS
A 13D automatic fire sprinkler system is required for this house, based on FD access issues, per review by Fire Marshall.
Routing - PLANNING Land Div9/21/2004 9/22/2004 PASS
Parcel B on ROS 6469. Approved as one-time lot split.
Routing - PUBLIC WORKS GRADING9/21/2004 9/21/2004 PASS
Approved as Category 3
Routing - PUBLIC WORKS9/21/2004 9/21/2004 PASS
Routing - PUBLIC WORKS GRADING8/18/2004 8/18/2004 FAIL
Foundation plan and grading plan must be in same datum. eepage bed must be a minimum of ten feet from the property line, as required by geotech report. Frank Jones was told when plans were originally left in mid July and again in a phone message on 8/13.
Application received  8/18/2004