Information based on query as of Thursday, July 18, 2024.
Permit Information
Permit NumberBLD04-02174
StatusFinaled
Name JIM DILDINE
Site Address 4027 W QUAIL HILL CT
Project NameHILLSIDE
Customer Number 
ePlanReviewNo
Description
To construct a 3676 sq. ft. two story single family dwelling with a 697 sq. ft. attached three car garage, a 40 sq. ft. covered entryway, a 136 sq. ft. 2nd level deck and concrete patio at rear of structure per approved plans, all engineering/red-lining and attached condition list. This lot is within a hillside area and is subject to the hillside ordinances. Class "A" roof system and 30 ft. defensible space shall be maintained. Unless otherwise approved by Boise City Fire Department this structure shall be fitted with a modified 13D sprinkler system, including sprinkler barrier protection between garage and dwelling in accordance with their listing requirements. This system shall be equipped with an alarm initiating device, commonly referred to as a flow switch, connected to an outside audible alarm. PC #617 CU94-90 DJO
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/25/20055/26/20055/26/2005PPASS
DetailsTony Young
josh; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Note: please call 1/2 hr prior to inspection
BLD-Grading Inspection5/26/20055/26/20055/26/2005 BOND
The right side of the lot must still be graded so that runoff will be retained and not allowed to be discharged to the lot below. The engineer has recommended a $500 bond to ensure satisfactory completion. Upon receipt of this bond the grading and drainage is conditionally approved.
DOC - Permit Finaled5/26/20055/26/20055/26/2005PPASS
DetailsTony Young
josh; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Note: please call 1/2 hr prior to inspection
BLD-Energy code compliance2/17/20052/18/20052/18/2005PPASS
DetailsTony Young
josh; Phone #: ###-#### Internet Inspection Request from: Jan Rice
BLD-Framing/Rough-in2/15/20052/16/20052/16/2005PPART
DetailsTony Young
josh Note: please call 1/2 hr prior to inspect; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
c/n,, ok to insulate 2/16/2005 4:16:56 PM
BLD-Framing/Rough-in1/31/20052/1/20052/1/2005APART
DetailsTony Young
josh -Note: please call 1/2 hr prior to inspection ; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
ext. shear ok 2/1/2005 9:41:07 AM
BLD-Framing/Rough-in1/27/20051/28/20051/28/2005ANR
DetailsTony Young
Josh; Phone #: ###-#### Internet Inspection Request from: Jan Rice
conf. only on frame 1/28/2005 10:13:07 AM
BLD-Wall cover1/26/20051/27/20051/27/2005ACANC
DetailsTony Young
Please call prior to inspection josh; Phone #: ###-#### Internet Inspection Request from: Barbara Moore,,, exterior shear
BLD-Conference1/26/20051/27/20051/27/2005PCANC
DetailsTony Young
Please call prior to inspection josh; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
BLD-Other1/27/20051/27/20051/27/2005AFAIL
DetailsTony Young
Please call prior to inspection josh; Phone #: ###-#### Internet Inspection Request from: Barbara Moore,,,ext shear,,,
c/n posted 1/27/2005 11:09:08 AM
BLD-Framing/Rough-in1/26/20051/26/20051/26/2005PCANC
DetailsTony Young
Please call prior to inspection josh; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
BLD-Foundation12/13/200412/14/200412/14/2004ADONE
DetailsTony Young
josh; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
poured w/out inspection yesterday 12/14/2004 10:53:02 AM
BLD-Footing12/2/200412/3/200412/3/2004APART
DetailsTony Young
Josh; Phone #: ###-#### Internet Inspection Request from: Jan Rice
BLD-Footing12/2/200412/2/200412/2/2004PPART
DetailsTony Young
josh, ###-####
wip,,, added this insp @ contractors request 12/2/2004 3:15:42 PM
BLD-Grading Inspection12/2/200412/2/200412/2/2004 DONE
Footing subgrade has been approved by the geotechnical engineer
PubWorks Subgrade Approval11/10/200411/10/200412/2/2004 DONE
A letter from the applicants geotechnical engineer indicating that the footing subgrade is acceptable must be approved by Public Works prior to calling for a footing inspection. Call Terry Records at ###-####.
Override - Activity Holds  11/30/2004  
Issue PAID IN FULL permit  11/30/2004 DONE
Override - Activity Holds  11/24/2004  
Permit Ready to Issue  11/24/2004 DONE
Override - Activity Holds  11/24/2004  
Inspection Record Card- Bld  11/24/2004 DONE
Print Occupancy Form  11/24/2004 DONE
Telephone call  11/24/2004 DONE
Spoke with Jim and told him that permit is ready & fess////11/24/04 12:32pm BAS
Plan Reviewer's activity  11/23/2004 DONE
plans stamped. ok to issue.
PLANS/APPL TAKEN TO FRONT DESK  11/23/2004 DONE
Plan Reviewer's activity  11/19/2004  
have contacted Jim Dildine. plan sets need engineers stamps. Jim will stop by and take plans to Lochsa to wet stamp. will continue review after receiveing stamped plans back.
Case Summary (BLD)  11/19/2004  
Plan Review Report  11/19/2004  
Plan assigned to (DJO)11/18/200411/18/200411/18/2004 DONE
Plan Reviewer's activity  11/18/2004 FAIL
have tried to reach Lee Harrison (Lochsa Eng.) for two day. have left messages. will not issue until lateral calculations are clarified. have notified Jim Dildine, builder. rescheck incorrect. will submit calculations that i have input.
Plans ACCEPTED BY PLAN CHECK  11/18/2004  
Pending Assignment by DJO9/17/2004 11/18/2004 DONE
11/18/2004 15:10:33 DJO - activity updated through activity BLDA169 from case BLD04-02174.
Routing - FIRE11/4/2004 11/5/2004 PASS
this house shall be fitted with an NFPA 13D automatic fire sprinkler system. Systems shall be modified by the installation of a single row of dry sidewall sprinklers along the wall common to attached garages and the living space. (Quail Ridge #9 sub)
Routing - PUBLIC WORKS GRADING11/1/2004 11/4/2004 PASS
Approved revised grading plan.
Routing - PLANNING11/4/2004 11/4/2004 PASS
O.K. per revised site plan. Floor plans have been redlined to provide a minimum front setback of 20'.
Routing - Erosion and Sediment11/4/2004 11/4/2004 PASS
ESC plan approved with attached conditions.
Routing - PLANNING9/27/2004 9/29/2004 FAIL
Driveway does not provide 22' of back-up as required.
Bump-out for television is not allowed to encroach into setback.
20' front setback required in subdivision.

Left message w/ applicant at 8:00 a.m. on 9/29/04.
Routing - PUBLIC WORKS9/23/2004 9/24/2004 PASS
Routing - PUBLIC WORKS GRADING9/17/2004 9/23/2004 PASS
Approved as category 3
Application received  9/17/2004  
Routing - PLAN CHECK11/5/2004