Permit Information
Permit NumberBLD04-02417
StatusFinaled
Name DBSI GROUP
Site Address 1233 S BROADWAY AVE
Project NameBROADWAY PLAZA
Customer Number 
ePlanReviewNo
Description
(BROADWAY PLAZA) To upgrade the south section of an existing 2-hour rated fire wall (area separation wall) that runs east to west by providing the required 30" minimum parapet above the lower roof per approved plans and an Upgrade Agreement on file. This fire wall separates a restaurant tenant on one side and retail spaces on the other side. This permit does not establish occupancy for any tenant. This is a Scope of Work Permit. A Letter of Completion is to be issued when done. Work to include a new 2-hour rated framed 30" minimum parapet extension, some steel brace members, new blocking where required, some new roofing, and some new exterior siding work. Architect has requested a Deferred Submittal for the structural calculations to both the Plan Reviewer and Building Inspector to be provided prior to any of the roofing membrane being installed. Special Inspection is required for any structural field welding (as shown) or another connection detail (such as bolts) will need to be provided. A Certificate of Compliance for any steel work done in an approved fabricator shop is to be provided to the inspector in the field. NOTE: This building is not fire sprinklered. JCB
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice BLD12/7/200512/7/200512/13/2005 DONE
Second Notice has not been responded to.
Second Notice 5/20/200512/7/2005 DONE
First Notice Sent 11/4/20044/26/2005 DONE
DOC - Permit Finaled11/4/200411/4/200411/4/2004APASS
DetailsJim Storey
Finaled by inspector at 11/4/2004 9:27:46 AM
BLD-Final11/3/200411/4/200411/4/2004APASS
DetailsJim Storey
dennis; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie final ok l/c 11/4/2004 9:27:44 AM
BLD-Framing/Rough-in10/21/200410/22/200410/22/2004APART
DetailsDave Hannah
dennis; Phone #: ###-#### Internet Inspection Request from: Jan Rice framing ok ok to start covering with sheetrock told contractor to install both layers then call for a inspecton befor they cover with flasing so screw patern can be checked 10/22/2004 9:27:25 AM
BLD-Energy code compliance10/22/200410/22/200410/22/2004PCANC
DetailsDave Hannah
dutch note; nail drywall Phone #: ###-#### Internet Inspection Request from: Jan Rice
BLD-Wall cover10/22/200410/22/200410/22/2004PPASS
DetailsDave Hannah
ok to cover perapet wall
Issue PAID IN FULL permit  10/21/2004 DONE
Plan Reviewer's activity  10/20/2004  
Check with Tempra Wilson concerning exterior work and there is no requirements.
PLANS/APPL TAKEN TO FRONT DESK  10/20/2004 PASS
Inspection Record Card- Bld  10/20/2004 DONE
Permit Ready to Issue  10/20/2004 DONE
Telephone call  10/20/2004 DONE
talked to shane hotchkiss at ###-#### or ###-#### that permit is ready
Plan assigned to (JCB)10/13/2004 10/20/2004 PASS
10/20/2004 13:14:42 JCB - activity updated through activity BLDA022 from case BLD04-02417.
Routing - PLAN CHECK10/15/2004 10/20/2004 PASS
Permit and plans approved and taken to front desk.
Plan resubmittals received  10/19/2004  
Two copies of resubmittal sheet T1.0 provided.
1st review completed  10/15/2004 FAIL
Failed in Plan Check.
Routing - PLAN CHECK10/13/2004 10/15/2004 FAIL
Called applicant concerning design and clarifications for the parapet extension project. Architect will be providing addendum sections.
Telephone call  10/15/2004  
Called applicant concerning design and clarifications for this project. Architect will be providing supplemental addendum sections.
Application received  10/13/2004  
Recd Pcfee & Taken To Pln CK  10/13/2004 DONE
Plans ACCEPTED BY PLAN TECH  10/13/2004 DONE
Ok per Bob Fulleton at ( CDH )He will not need to see these plans as they are only putting in a seperation wall..
Fee Review-notes10/13/200410/13/2004