Information based on query as of Sunday, August 18, 2024.
Permit Information
Permit NumberBLD04-02630
StatusFinaled
Name ROBNETT CONSTRUCITON
Site Address 8752 W OVERLAND RD
Project Name 
Customer Number 
ePlanReviewNo
Description
(LIGHTEN UP) To construct a new tenant separation wall to create a new 806 sq.ft. tenant space for professional service for a weight monitoring, reduction & client support business. Work includes construction of a full height frame wall, fully insulated for sound control, 5/8" sheetrock covering wiyth texture & paint to create an open business area. The existing ceiling is a 1-hour roof/ceiling assembly created under the shell & core permit as an alternate to construction of a parapet on the east wall. All penetrations of the 1-hour roof/ceiling assembly require protection to maintain the rating. An HVAC unit is shared by two tenant with controls in other tenant space. Entry to this space is an existing 20 minute door assembly from the existing 1-hour corridor serving the building. There are two fully accessible common restrooms serving the building accessed from the common corridor. Exterior walls were insulated under the shell & core permit with finish under this permit. To upgrade electrical & mechanical under this permit for tenant needs and code compliance. DRH04-00010 Sara Schafer. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice BLD5/20/20055/20/200512/9/2005 DONE
Second Notice has not been responded to.///Over a year old No final values
Second Notice BLD4/26/20054/26/20055/20/2005 DONE
First Notice has not been responded to.
First Notice 2/2/20054/26/2005 DONE
Permanent occupancy  2/2/2005 DONE
Perm. Occ. Cert. # 10433 issued 2-2-05 to Lighten Up.
BLD-Final1/27/20051/28/20051/28/2005APASS
DetailsLane Manuel
###-#### - gary
Perm. C of O OK 1/28/2005 10:40:35 AM
Permanent Occupancy 1/28/20051/28/2005 DONE
Details
Temporary occupancy  1/20/2005 DONE
Temp. Occ. Cert. # 5192 issued 1-20-05 to Llighten Up.
BLD-Final1/14/20051/14/20051/14/2005PPART
DetailsLane Manuel
gary; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
needs rated attic access door, and corrections for fire dampers 1/14/2005 2:41:46 PM
FIRE-Final Inspection1/12/20051/12/20051/12/2005PPASS
DetailsRick Jackson
gary; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie There is new AHU that is under 2000 cfm per GC - detector not required; dampers installed in 1 hr ceiling 1/12/2005 3:28:47 PM
BLD-Wall cover12/27/200412/27/200412/27/2004PPART
DetailsLane Manuel
Gary; Phone #: ###-#### Internet Inspection Request from: Jan Rice
drywall screwing on 1 hr. ceiling ok 12/27/2004 3:17:30 PM
BLD-Energy code compliance12/22/200412/22/200412/22/2004PPASS
DetailsLane Manuel
gary; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
r-19 walls 12/22/2004 4:05:57 PM
BLD-Framing/Rough-in12/20/200412/20/200412/20/2004PPART
DetailsLane Manuel
Gary; Phone #: ###-#### Internet Inspection Request from: Jan Rice
BLD-Framing/Rough-in12/17/200412/17/200412/17/2004PPART
DetailsLane Manuel
gary; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
need to obtain mechanical permit, and get rough in approval prior to insulating. 12/17/2004 1:17:20 PM
Permit Ready to Issue  12/13/2004  
Inspection Record Card- Bld  12/13/2004 DONE
Print Occupancy Form  12/13/2004 DONE
Print Occupancy Form  12/13/2004 DONE
Telephone call  12/13/2004 DONE
Spoke with elaina and told her that permit is ready & fees///12/13/04 10:35am BAS
Issue PAID IN FULL permit  12/13/2004 DONE
PLANS/APPL TAKEN TO FRONT DESK  12/10/2004 PASS
To permit desk to issue.
Routing - PLAN CHECK11/29/2004 12/10/2004 PASS
Inserted resubmittals. Approved as noted on and attached plan reviews.
Plan assigned to (DRS)11/3/2004 12/10/2004 PASS
12/10/2004 11:56:48 DRS - activity updated through activity BLDA022 from case BLD04-02630.
Plan resubmittals received  12/9/2004 DONE
Received two copies of revised sheets 3, 4 and lighting compliance. Routed to Dan S. kmm
Routing - FIRE11/22/2004 11/29/2004 PASS
1st review completed  11/29/2004 FAIL
failed plan check.
Routing - PLAN CHECK11/8/2004 11/18/2004 FAIL
PLANS INCOMPLETE FOR FURTHER CIRCULATION FOR REVIEW. 1-HOUR ROOF/CEILING SYSTEM ON EAST HALF OF BUILDING UNDER SHELL & CORE PERMIT WAS NOT ADDRESSED NOR ALL THE PENETRATIONS INDICATED ON PLANS. HAVE FAXED COMMENTS TO AND TALKED ON PHONE WITH JAMES GIBSON, ARCHITECT. ALSO TALKED WITH BRETT CLARK, ROBNETT CONSTRUCTION.
Routing - PUBLIC WORKS11/4/2004 11/8/2004 PASS
Plan resubmittals received  11/4/2004 DONE
Received 3 copys of the compliance sheets
Application received  11/3/2004  
Recd Pcfee & Taken To Pln CK  11/3/2004 DONE
Plans ACCEPTED BY PLAN TECH  11/3/2004 PEND
Need HVAC Calcs, Mechanical Comcheck to be on plan sheet..