Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD04-02876
StatusFinaled
Name DEVCON CONSTRUCTION INC
Site Address 495 S CAPITOL BLVD
Project NameBODO BLDG #8
Customer Number 
ePlanReviewNo
Description
*BODO Building #8 - Hampton Inns Hotel (Shell) - per Cody R. no occupancy on the Hotel ONLY until the DR requirements are met. (the Retail is ok) Exterior Paint color not correct.To construct a new 235,965 square foot, eleven story high rise, concrete and steel framed retail, parking and hotel shell building. When finished, the first floor will contain 7,775 sq. ft. of retail space, 9,000 sq. ft. of hotel lobby space and 19,020 sq. ft. of parking garage space (total 35,795 sq. ft.). The second, third and fourth floors will be parking garage (34,750 sq. ft. each floor, total of 104,250 sq. ft.). The fifth floor will contain hotel rooms, laundry, meeting rooms, exercise room and indoor swimming pool (16,000 sq. ft.). The sixth through eleventh floors will contain hotel guest rooms (13,320 sq. ft. per floor, total 79,920 sq. ft.). This is a shell permit only. No occupancy is allowed under this permit. A separate tenant improvement permit is required to finish this building for occupancy. The fire-resistance rating reductions allowed by IBC, Sections 403.3.1 and 403.3.2 is being used to reduce the required fire-resistive rating from Type IB to Type IIA. The reduction is allowed in this building with the use of sprinkler control valves equipped with supervisory initiating devices and water-flow initiating devices for each floor. The other requirement of this reduction is the construction of two-hour fire-barriers between the first floor mercantile occupancies and the remainder of the building. All construction per the approved plans and attached comment list. JCM
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  4/7/2016 DONE
Letter of compliance  6/29/2007 DONE
Letter of Compliance issued 6-29-07
BLD-Final2/2/20072/5/20072/5/2007PNR
DetailsDave Hannah
dennis; Phone #: ###-#### Internet Inspection Request from: Victoria Beall needs other trades finaled
FIRE-Final Inspection2/2/20072/5/20072/5/2007APART
DetailsForrest France
Final fire life safety pending completion of correction notice items for the permit attatched fire alarm and sprinkler permits, see c/n dated 2/2/07.
Inspection Record Card- Bld  3/2/2006 DONE
Inspection Record Card- Bld  3/2/2006 DONE
BLD-Other2/16/20062/16/20062/16/2006PDONE
DetailsDave Hannah
Dave: Please call Dennis -###-#### for garage walk-though and hotel fire proofing detail (small) discussion. Internet Inspection Request from: Alex Monge
BLD-Conference2/1/20062/2/20062/2/2006APASS
DetailsDave Hannah
Bulding 8 conference...call dennis. Internet Inspection Request from: Alex Monge
BLD-Other1/20/20061/20/20061/23/2006PPASS
DetailsDave Hannah
Contact Dennis Harter; Phone #: ###-#### Internet Inspection Request from: Ben Kos
BLD-Conference1/13/20061/16/20061/17/2006PDONE
DetailsDave Hannah
Dennis Harter Request; Phone #: ###-#### Internet Inspection Request from: Alex Monge
BLD-Conference1/10/20061/11/20061/12/2006PDONE
DetailsDave Hannah
Phone #: ###-#### Internet Inspection Request from: Alex Monge
BLD-Other1/9/20061/10/20061/11/2006PDONE
DetailsDave Hannah
Phone #: ###-#### Internet Inspection Request from: Alex Monge
BLD-Framing/Rough-in12/19/200512/20/200512/21/2005APART
DetailsDave Hannah
Lombac Requested Framing Inspection; Phone #: ###-#### Internet Inspection Request from: Alex Monge walked garage area every thing looking good
BLD-Framing/Rough-in12/8/200512/8/200512/8/2005PPART
DetailsDave Hannah
Please call John with Lombac; Phone #: ###-#### Internet Inspection Request from: Ben Kos
BLD-Framing/Rough-in12/7/200512/8/200512/8/2005APART
DetailsDave Hannah
Please call John with Lombac; Phone #: ###-#### Internet Inspection Request from: Ben Kos shafts stair towers walls ground floor to third floor looking good to this point
BLD-Framing/Rough-in11/11/200511/15/200511/16/2005APART
DetailsDave Hannah
John Woods w/Lombac; Phone #: ###-#### Internet Inspection Request from: Alex tenent seperation between garage gruond floor ok for second layer
BLD-Framing/Rough-in10/21/200510/24/200510/24/2005APART
DetailsDave Hannah
John Woods is contact number provided; Phone #: ###-#### Internet Inspection Request from: Alex Monge walked stairs for garage ok to proceed
BLD-Framing/Rough-in10/12/200510/12/200510/13/2005PPART
DetailsDave Hannah
Building #8 Exterior Framing; Phone #: ###-#### Internet Inspection Request from: Alex Monge looked at ext framing roof to 4th floor
BLD-Conference10/11/200510/12/200510/13/2005ADONE
DetailsDave Hannah
Building #8 Exterior Framing; Phone #: ###-#### Internet Inspection Request from: Alex Monge
Plan resubmittals received  9/23/2005  
Received (2) copies of sheet S3.5. Routed to John M.
BLD-Framing/Rough-in9/16/20059/16/20059/19/2005PPART
DetailsDave Hannah
Call John with Lombac; Phone #: ###-#### Internet Inspection Request from: Ben Kos walled floors 5 to roof looking at ext wall framing everything ok to date
BLD-Framing/Rough-in9/13/20059/15/20059/16/2005PPART
DetailsDave Hannah
Call John with Lombac; Phone #: ###-#### Internet Inspection Request from: Ben Kos walked project to look at ext framing
FIRE-Conference8/2/20058/2/20058/2/2005ADONE
DetailsForrest France
On site discussion with Wil Northup and Bill Alexander regarding the installation of an above ground water storage tank for supplemental fire sprinkler supply. The tank was installed without an FIR permit and thus not reviewed or approved for code compliance. The general and subcontractors involved were made aware of the situation.
BLD-Conference5/4/20055/5/20055/5/2005ADONE
DetailsDave Hannah
pre construction meeting
Voucher Form  4/28/2005 DONE
(F) Reprint permit  4/18/2005  
Issue PAID IN FULL permit  4/15/2005 DONE
Telephone call  4/12/2005 DONE
left mess for james woodbury at ###-#### permit is ready & need something from achd
Plan assigned to (JCM)12/10/200412/10/20044/11/2005 PASS
4/11/2005 14:06:17 JCM - activity updated through activity BLDA022 from case BLD04-02876.
Routing - PLUMBING4/11/2005 4/11/2005 PASS
the plumbing for this project has not been reviewed for this shell permit. plumbing plans must be submitted with the tenant improvement plans for review.
Routing - PLAN CHECK4/11/2005 4/11/2005 PASS
PLANS/APPL TAKEN TO FRONT DESK  4/11/2005 DONE
Inspection Record Card- Bld  4/11/2005 DONE
Permit Ready to Issue  4/11/2005 DONE
Routing - PLANNING4/8/2005 4/8/2005 PASS
Approved per DRH03-187 and as noted on sheet A3.4 for decorative concrete at pilaster bases.
Routing - FIRE3/29/2005 4/7/2005 PASS
resubmittal acceptable subject to conditions noted in revised plan review comments, comments faxed to architect.
Plan resubmittals received  3/30/2005 DONE
Resubmittals received and forwarded to John M.: 4 copies of plan sheets A3.1, A3.2, A3.3 and A3.4.
Routing - PLAN CHECK3/28/2005 3/29/2005 PASS
Plan Reviewer's activity  3/29/2005 PASS
Reviewed and approved resubmitted plans sheets for shell permit. JCM
Routing - PUBLIC WORKS3/25/2005 3/28/2005 PASS
Plans taken to Kent Johnson on 3-25-05
Routing - PUBLIC WORKS3/9/2005 3/23/2005  
Routing Off Site - STRUCTURAL2/15/2005 3/18/2005 PASS
Called PDQ for pick up. - Received an e-mailed letter from the consulting structural engineer approving the 3rd and final review for this project. JCM
Plan resubmittals received  3/11/2005 DONE
Received 2 Letters/Building Code Review ,4 Copys of sheets A0.1,A1.2,A2.12,A7.1,A7.5 & 3 Copys of sheet S1.1 Taken to John M.
Routing - PLAN CHECK1/19/2005 3/9/2005  
Plan resubmittals received  3/2/2005 DONE
1 ESC sheets C1.2A and C1.2B with updated comments reflecting ACHD requirements received and forwarded to John M.
Plan resubmittals received  2/10/2005 DONE
Recvd 1 transmillat letter; 4 copies of C1.1, A1.1, A1.2, A2.12, A7.5; 3 copies of Structrual calc for plan check response 2nd submittal taken to John Menard///2/10/05 BAS
Plan resubmittals requested  2/4/2005 DONE
E-mailed the applicant with a copy of the structural review comments requesting additional revisions. JCM
Routing Off Site - STRUCTURAL1/31/2005 2/3/2005 FAIL
Called PDQ for pick up --- Received comment list from constulting structural engineer requesting additional revisions. JCM
Plan resubmittals received  1/28/2005 DONE
Received Transmittal, 1 Letter, 4 Structural Calcs & 4 Copys of sheets S1.1, S1.2, S2.1, S3.5, S3.6 . Taken to John M.
1st review completed  1/19/2005 FAIL
failed planning, plan check, plumbing, structural, ESC, and fire.
Routing - FIRE1/10/2005 1/19/2005 FAIL
Failed due to insufficient information regarding all aspects of fire protection requirements. Review faxed to architect.
Routing - PLAN CHECK12/29/2004 1/10/2005 FAIL
John M.
Plan resubmittals requested  1/10/2005 DONE
E-mailed the applicant with a copy of the plan review comment list requesting revisions. JCM
Plan resubmittals requested  1/3/2005  
E-mailed the applicant a copy of the comment list from the consulting structural engineer requesting revisions. JCM
Routing Off Site - STRUCTURAL12/16/2004 1/3/2005 FAIL
contacted PDQ for outside delivery of soils report.rad - Received comment list from consulting structural engineer requesting revisions. JCM
Routing - PLANNING12/22/2004 12/29/2004 FAIL
Plans do not comply with the most recent Design Review Committee action or per the original Design Review conditions. DRH03-00187
Routing - PLUMBING12/16/2004 12/22/2004 FAIL
7.General note 4- 1/4" per foot grade min. on 3" and smaller, 1/8" per foot 4" and larger. 8. Provide calculations for water pipe sizing, gpms for pipe sizes 4"thru 1/2". 9.provide fixture schedule. 10. A4.3 shows 6 lavs in the public restrooms P1.4 shows 4. 11.Provide information on pool equipment connections. 12. Use boise city approved flammable liquids interceptor detail, attached. , 1. H.E.2 must be double wall with leak detection. 2. waste main is undersized. 3.locate riser diagrams on plan.4.suds relief, no connections to a waste stack within 8' verticaly or horizontaly, 5. tub trap arms 2" limited to 5'. 6. detail 10 page A8.2 wet venting limited to 1 and 2 fixture unit fixtures.
Plan resubmittals received  12/22/2004  
Routing - Erosion and Sediment12/22/2004 12/22/2004 PASS
ESC plan approved with attached conditions.
Plan Reviewer's activity  12/22/2004 DONE
E-mailed Sylvester to request clarification on the extent of construction this permit was intended to cover. JCM
Plan resubmittals received  12/21/2004 DONE
Received fire flow information from Sylvester Ramirez and inserted info into plans currently routing.
Routing - PUBLIC WORKS12/10/2004 12/16/2004 PASS
Routing - Erosion and Sediment12/16/2004 12/16/2004 FAIL
ESC plan, waiver or refer to Master plan under another ESC permit number is needed. Discussed with RP Dave Anderson, will address and get back to me.
Plan resubmittals received  12/16/2004 DONE
Received four copies of sheet EN-1 and four copies of sheet A2.1.
Sheet A2.1 is not signed by the Arch. but is for CDH signature only. Received two copies of Geotech. report. Routed to John M. kmm
Routing - PLANNING Land Div12/10/2004 12/10/2004 PASS
Block 8 of Davis Addition and vacated alley.
Plan routing begun/NEW & ADDTN  12/10/2004  
Plans ACCEPTED BY PLAN TECH  12/10/2004 PEND
Plan is missing ESC plan and narrative, United water fire flow, Soils report.rad
Application received  12/9/2004  
Routing Off Site - STRUCTURAL12/10/2004    
Contacted PDQ for outside delivery.