Permit Information
Permit NumberBLD04-02877
StatusFinaled
Name BLEDSOE CONSTRUCTION
Site Address 2990 S WISE WAY
Project Name 
Customer Number 
ePlanReviewNo
Description
*(The Bledsoe Group)* To remodel an existing cabinet shop by upgrading requirements to the dust collection system, spray room & construct of a small exterior shed to house compressors. This building is fully fire sprinklered. The building has been classified as a TYPE VB Construction.This building is fully fire sprinklered for area increase. Any alterations or modifications to the sprinkler system shall be per NFPA #13 as regulated by the fire department. (RmH)
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  8/18/2006 DONE
BLD-Final5/24/20055/25/20055/25/2005APASS
DetailsDave Hannah
harry; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok for perm occ
Letter of compliance  5/25/2005 DONE
Letter of Compliaince issued 5-25-05.
FIRE-Final Inspection5/23/20055/24/20055/24/2005APASS
DetailsForrest France
Fire life safety finaled.
FIRE-Final Inspection5/3/20055/4/20055/4/2005ACANC
DetailsForrest France
Cancel inspection per. general contractor, not ready.
BLD-Final4/18/20054/19/20054/19/2005PPART
DetailsTroy James
Scheduled by a contractor via Hello! on 4/18/2005 at 3:33:23 PM. Contact: ###-####. Need fire approval and mechanical permit and approval for dust collection. 4/19/2005 1:43:56 PM
BLD-Final4/19/20054/19/20054/19/2005APART
DetailsForrest France
Temp. occupancy given per. Dave Lokker, pending fire alarm and fire sprinkler modifications.
FIRE-Final Inspection4/19/20054/19/20054/19/2005APART
DetailsForrest France
Temp. occupancy given per. Dave Lokker, pending fire sprinkler modifications in spray booth and compressor room.
FIRE-Alarm Testing4/19/20054/19/20054/19/2005APART
DetailsForrest France
Temp. occupancy given per. Dave Lokker, pending fire alarm modifications to include addition of three tamper switches and one flow switch addressed to 2990 Wise Way.
Telephone call  3/23/2005 DONE
Telcon with Randy Sycamora, ADT who is to provide the alarm monitoring for Bledsoe and Rick Jackson, Allied General (3.24) who provides monitoring for Shakespeare and the site fire pump. Bledsoe shall provide their own FACP monitoring the outside PIV on Wise, which serves their building and all other sprinkler valves and flow switches required for the sprinkler system to be installed in Bledsoe, and including any HVAC duct smoke detectors, etc. The Shakespeare FACP provides pump monitoring and will need to remove the exisitng flow switch at the discharge of the fire pump and be sure the "pump running" signal is a supervisory, not an alarm signal. This will allow Bledsoe to test their system without creating an alarm signal at Shakespeare which would result in rolling the FD. It will also preserve the required fire pump monitoring and all related contral valve monitoring per 72 and 20 which will be done solely by Shakespeare's FACP. The fire pump arrangement was initially approved by the county when both buildings were part of the same facility. It has since been divided into two separate properties creating this problem of how to divide responsibility for FP monitoring and avoid duplicate alarm signals to the FD.
BLD-Conference3/9/20053/10/20053/10/2005ADONE
DetailsTroy James
###-#### steven
FIRE-Final Inspection3/9/20053/9/20053/9/2005PFAIL
DetailsTroy Cobbley
See fire dept review notes for my comments on items needing verified. 3/9/2005 12:39:53 PM
Issue PAID IN FULL permit  2/22/2005 DONE
Plan assigned to (R_H)12/10/2004 2/18/2005 PASS
2/18/2005 10:28:48 RMH - activity updated through activity BLDA022 from case BLD04-02877.
Routing - PLAN CHECK2/17/2005 2/18/2005 PASS
Case Summary (BLD)  2/18/2005 DONE
PLANS/APPL TAKEN TO FRONT DESK  2/18/2005 DONE
Inspection Record Card- Bld  2/18/2005 DONE
Print Occupancy Form  2/18/2005 DONE
Permit Ready to Issue  2/18/2005 DONE
Telephone call  2/18/2005 DONE
lft vm with chad slister ###-#### that permit and fees are ready to be picked up
Routing - FIRE2/11/2005 2/17/2005 PASS
resubmittal acceptable. revised review comments faxed to archtiect.
Plan resubmittals received  2/8/2005 DONE
Received 2 Letters,2 Review Letters, 2 HVAC Letters,2 Material Safty Data Sheets, 2 Hazard Communications, & 2 Copys of sheets A2.0, A2.2, M-2 Taken to Ron H.
1st review completed  12/30/2004 FAIL
failed Fire.
Routing - FIRE12/22/2004 12/30/2004 FAIL
Spray room design not in compliance with codes; submittal lacks significant information. Review faxed to architect.
Routing - PLAN CHECK12/21/2004 12/22/2004 PEND
No corrections required by building department plan review, Routed plans to fire for review on 12/22/04 Permit pending fires review
Case Summary (BLD)  12/22/2004 DONE
Case Summary (BLD)  12/22/2004 DONE
Routing - PLANNING12/13/2004 12/21/2004 PASS
Routed to Scotts desk on 12/13/04
Routing - PUBLIC WORKS12/10/2004 12/13/2004 PASS
Application received  12/9/2004  
Recd Pcfee & Taken To Pln CK  12/9/2004  
Plans ACCEPTED BY PLAN TECH  12/9/2004  
Fee Review-notes12/9/200412/9/2004   
Routing - PLAN CHECK12/30/2004