Information based on query as of Sunday, June 30, 2024.
Permit Information
Permit NumberBLD05-00060
StatusFinaled
Name FIDELITY PROPERTY INPROVEMENTS
Site Address 1423 W GROVE ST
Project NameFURNESS BLDG
Customer Number 
ePlanReviewNo
Description
(SECOND CHANCE BUILDING REUSE CENTER)(FURNESS BLDG) Remodel for a new 9,490 sq. ft. retail and storage warehouse tenant in an existing 14,352 sq. ft. building per CUP04-00133, DRH05-00009, and approved plans. Work to include constructing a new interior 3-hour rated fire barrier wall to roof deck at the east wall of the tenant space, some new interior walls and doors, insulating and providing gypsum board on existing walls that had pegboard, new draft stop in attic, new exterior awnings/canopies, CMU infill in some existing openings in the west and south exterior walls, upgrading restrooms to current accessibility standards, interior finish, mechanical work, plumbing work, and electrical work. Special Inspection required for epoxy/adhesive anchor installations at masonry infill work and for structural welding at the awning/canopy construction. No storage racking exceeding 8' in height allowed in the space. East wall of this space is a 3-hour rated fire barrier wall to reduce the fire areas in this building to less than 12,000 sq. ft. South wall of this space is a 2-hour rated exterior bearing wall based on type of construction located 8' to the centerline of the alley with 12" parapet and unprotected openings. The north wall is a 2-hour rated exterior bearing wall based on type of construction with unprotected openings. Nonseparated Uses and Separated Uses in this building.NOTE: DO NOT ISSUE A PERMANENT CERTIFICATE OF OCCUPANCY UNTIL THE CROSS ACCESS AGREEMENT HAS BEEN APPROVED BY PLANNING. A Certificate of Occupancy is to be issued when completed and approved. NOTE: This building is not fire sprinklered. JCB
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice BLD12/6/200512/6/200512/23/2005 DONE
Second Notice has not been responded to.
Second Notice BLD7/13/20057/13/200512/6/2005 DONE
First Notice has not been responded to.
BLD-Final8/18/20058/18/20058/19/2005PPASS
DetailsDave Hannah
###-#### - scott ok for perm occ
Permanent Occupancy 8/19/20058/19/2005 DONE
Details
Reopen Permit (ISS)  8/18/2005 DONE
per dave hannan - final bld was not ready to close
First Notice 6/1/20057/13/2005 DONE
Permanent occupancy UNPAID FEE  6/1/2005 DONE
Perm. Occ. Cert. # 10614 issued 6-1-05 to the Second Chance Building Reuse Center.
Permanent Occupancy 5/19/20055/19/2005 DONE
Details
Temporary occupancy  5/10/2005 DONE
Temp. Occ. Cert. # 5239 issued 5-10-05 to Second Chance Building Reuse Center.
BLD-Final5/5/20055/6/20055/6/2005PPART
DetailsDave Hannah
scott; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok for temp occ ok for perm after other trades sign off perm
BLD-Final5/5/20055/5/20055/5/2005PNR
DetailsDave Hannah
scott; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa needs fire and zoning sign off
FIRE-Final Inspection5/5/20055/5/20055/5/2005PPASS
DetailsForrest France
Fire life safety finaled.
FIRE-Final Inspection5/3/20055/4/20055/4/2005PFAIL
DetailsForrest France
Provide building street address. Lower fire ext. in middle of back warehouse to 48" or less above floor. Provide approved door hardware on main entry/exits per. note #8 on plan review. Provide approved door hardware on office doors and rear exit door,
Plan Reviewer's activity  5/4/2005 DONE
Per Carl Miller of Planning, a copy of the recorded Cross Access Agreement has been provided.
Override - Parcel Holds1/1/19001/1/19005/3/2005  
doesnt matter
Case Summary (BLD)  5/3/2005  
BLD-Framing/Rough-in4/12/20054/12/20054/12/2005PPASS
DetailsTom Arcoraci
scott; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles drywall 1st 2 layers 0k 4/12/2005 1:51:10 PM
Override - Parcel Holds1/1/19001/1/19004/12/2005  
BLD-Framing/Rough-in4/7/20054/8/20054/8/2005APASS
DetailsDave Hannah
scott; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
Override - Parcel Holds1/1/19001/1/19004/7/2005  
need a fr insp
Plan resubmittals received  3/30/2005 DONE
Received 2 Letters & 2 Copys of sheets C0,C1,A.1,A.2,A.3,E.1,E.2,P.1,N1,N2 Taken to Jason B.
Routing - PLAN CHECK3/25/2005 3/28/2005 PEND
Permit approval dependent on approval by Planning. Plans to route to Carl Miller in Planning for review.
Routing - PLANNING3/28/2005 3/28/2005 PASS
Approved. Cross access agreement will need to be recorded prior to occupancy.
Routing - PLAN CHECK3/28/2005 3/28/2005 PASS
Permit and plans approved and taken to front desk.
PLANS/APPL TAKEN TO FRONT DESK  3/28/2005 PASS
Permit Ready to Issue  3/28/2005  
Inspection Record Card- Bld  3/28/2005  
Print Occupancy Form  3/28/2005  
Telephone call  3/28/2005 DONE
left mess for dave hale at ###-#### is ready
Issue PAID IN FULL permit  3/28/2005  
Plan assigned to (JCB)1/12/2005 3/28/2005 PASS
3/28/2005 13:49:38 JCB - activity updated through activity BLDA022 from case BLD05-00060.
Routing - Erosion and Sediment3/25/2005 3/25/2005 PASS
ESC plan waiver request approved with attached conditions.
Routing - FIRE3/17/2005 3/25/2005 PASS
Review comments faxed to architect. After Fire route to ESC.
Routing - PLANNING3/11/2005 3/17/2005 FAIL
pending variance signature. Failed by Carl. Mutual access easement needs approval.
Routing - PLANNING3/3/2005 3/11/2005 PASS
Marty. Approved per DRH05-9 and as noted.
Routing - PLAN CHECK1/27/2005 3/3/2005 PEND
Permit pending approval by Planning and the Fire Department. Plans to route to these divisions for review.
Plan resubmittals received  3/2/2005 DONE
Received 3 sets of structural engineering calculations and forwarded them to Jason.
Plan resubmittals received  2/22/2005 DONE
Received 2 Letter, 2 Applications & 6 Copys of sheets A1.0,A2.0,A3.0,E1,L-1 Taken to Jason B.
Routing - PLANNING1/27/2005 1/27/2005 FAIL
Carl Miller CUP04-00133, failed has not passed appeal period for CU,
Marty Santoyo DRH05-00009
1st review completed  1/27/2005 FAIL
failed planning and plan check.
Routing - FIRE1/27/2005 1/27/2005 FAIL
postponed fire review at request of builidng, pending resolution of Building plan review issues. no fire review comments developed.
Routing - PLAN CHECK1/14/2005 1/26/2005 FAIL
Met with owner David Hale and architect Sherry McKibben to discuss several issues with this project. This building may now be split into two separate spaces. A separate address and application will need to be provided for the other space. Some issues will need to be verified and others addressed to know direction or approach to complete review of this project. Resubmittal plans need to be provided. A building upgrade agreement may be forthcoming. Plans to route to Planning and to Fire Dept. to complete 1st review routing.
Telephone call  1/26/2005  
Talked with architect Sherry McKibben concerning several code issues. She said she would talk with owner/developer and get back to me. Resubmittal plans will be required.
Meeting  1/26/2005  
Met with owner David Hale and architect Sherry McKibben to discuss several issues with this project. This building may now be split into two separate spaces. A separate address and application will need to be provided for the other space. Some issues will need to be verified and others addressed to know direction or approach to complete review of this project. Resubmittal plans need to be provided. A building upgrade agreement may be forthcoming.
Telephone call  1/25/2005  
Called owner to set up meeting with architect to go over code issues. He said he would get back to me.
Routing - PUBLIC WORKS1/12/2005 1/14/2005 PASS
Plans ACCEPTED BY PLAN TECH  1/12/2005 DONE
No esc plan or narraitve, no lighting compliance submitted.
David is aware of this.
Application received  1/11/2005  
Recd Pcfee & Taken To Pln CK  1/11/2005  
Fee Review-notes1/11/20051/11/2005