Permit Information
Permit NumberBLD05-00293
StatusExpired
Name ATWATER CONSTRUCTION
Site Address 20 S AUTO DR
Project NameAUTO MALL OUTLET
Customer Number 
ePlanReviewNo
Description
(AUTO MALL OUTLET) To install 3/4 hour fire rated wire glass storefront and non-rated glass window/door assembly on the east side of building per approved plans and CZC04-0002. Work includes demolition of a 30' wide by 9' tall portion of the existing concrete double tee wall; installation of new concrete support footings for (4) 6" x 6" x 1/4" TS columns with (2) rows C8 x 11.5 steel channels welded to 3/4" steel plates which are to be bolted with (2) 3/4", A325 bolts to steel angles that are welded to the columns; 'C' channels are bolted to the concrete tee's with 3/4" anchors at 4' o.c., 2 per tee with 4" minimum embed, all as indicated on plans and attached engineering design data. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  11/24/2009 DONE
BLD-Aging Inspection3/8/20063/8/20063/8/2006 CANC
DetailsMike Jordan
DOC - Permit Expired3/8/20063/8/20063/8/2006PPASS
DetailsMike Jordan
Issue PAID IN FULL permit  8/29/2005 DONE
Telephone call  8/25/2005 DONE
talked to preston baker at ###-#### that permit is ready
Inspection Record Card- Bld  8/24/2005 DONE
OVERRIDE  8/23/2005  
Permit Ready to Issue  8/23/2005 DONE
PLANS/APPL TAKEN TO FRONT DESK  8/22/2005 PASS
To permit desk.
Plan assigned to (DRS)2/11/2005 8/22/2005 PASS
8/22/2005 17:50:14 DRS - activity updated through activity BLDA022 from case BLD05-00293.
Routing - PLAN CHECK5/2/2005 8/22/2005 PASS
Resubmittals from architect correcting plans inserted and approved.
Plan resubmittals received  8/16/2005  
Received (3) copies of sheet A0-1, A1-1, A2-1 and S-1. Also received sprecial inspection documentation and quality assurance plan. Routed to Dan S.
Telephone call  8/1/2005 DONE
Called Jerry Teale to see if project was still going to be done. He thought it was and has been working on resubs. I let him know we were coming up on 180 since submittal of first plans and application and could be expired if plans not re-submitted or an extension approved by the building official.
Telephone call  5/2/2005 DONE
Call Jerry Teale to let him know that the ESC application and permit has been approved and all that is needed is his resubmittal data in response to plan review conditions. He said he would work on getting the information resubmitted.
Routing - Erosion and Sediment5/2/2005 5/2/2005 PASS
ESC plan waiver request approved with attached conditions.
Routing - PLAN CHECK3/15/2005 5/2/2005 PEND
Routing to Steve Webb for ESC review.
Telephone call  4/8/2005 DONE
Called Jerry to make sure he had received my plan review requirements. He said he did and had had several small projects come up before he can get back to respond.
Telephone call  4/8/2005 DONE
Called Atwood construction to check on ESC Application. Told Preston he could go on line and download app, complete it and fax it to use. He said okay.
Routing - Erosion and Sediment3/29/2005 3/29/2005 FAIL
Routing to Steve Webb for review. Plan waiver request approved but no application, informed owner that one is needed. Talked to Dan S. I will keep the plans until esc application is submitted.
1st review completed  3/15/2005 FAIL
failed plan check
Routing - FIRE3/9/2005 3/15/2005 PASS
No review comments required.
Plan resubmittals requested  3/9/2005 DONE
Copy of corrections required e-mailed and faxed to architect.
Routing - PLAN CHECK2/17/2005 3/9/2005 FAIL
Corrections required. Copy of corrections e-mailed and faxed to architect. Routing to fire code analyst for review.
Routing - PLANNING2/11/2005 2/17/2005 PASS
Per conditions of CZC04-00021.
Plans ACCEPTED BY PLAN TECH  2/8/2005  
Application received  2/7/2005  
Recd Pcfee & Taken To Pln CK  2/7/2005