Information based on query as of Sunday, June 30, 2024.
Permit Information
Permit NumberBLD05-00725
StatusFinaled
Name ROBERT R COOPER
Site Address 1307 E CANDLERIDGE DR
Project Name 
Customer Number 
ePlanReviewNo
Description
this fully engineered project in the hillside area is for a 1,552s.f. addition to an existing 3,843s.f. 2-story single family dwelling Separate electrical, plumbing, mechanical and ESC permits are required. "A letter from the applicant's geotechnical engineer indicating that the footing subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Terry Records at 384-3946" R-1B setbacks ok per eeg. All per the approved plans as marked, REScheck, ESC plans, Engineering and Engineering calculations along with the plan review notes. pep
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/14/20066/14/20066/14/2006PPASS
DetailsDave Hannah
Derek, please call 1st for access; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
DOC - Permit Finaled6/14/20066/14/20066/14/2006PPASS
DetailsDave Hannah
BLD-Final6/13/20066/13/20066/13/2006PFAIL
DetailsDave Hannah
Derek; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles needs elec final needs smoke dectors needs handrails with returns ok to leave second floor area unfinish if all other trades can final
BLD-Final6/12/20066/13/20066/13/2006ADEFR
DetailsDave Hannah
Derek; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
BLD-Conference3/9/20063/9/20063/10/2006PPART
DetailsDave Hannah
derrick -call 1st before insp ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie hand rail on outside front stairs
BLD-Energy code compliance12/9/200512/12/200512/12/2005APASS
DetailsDave Hannah
derek; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
BLD-Framing/Rough-in12/5/200512/5/200512/5/2005PPASS
DetailsDave Hannah
derrick; Phone #: ###-#### Internet Inspection Request from: Barbara Moore all c/n itims are complete seal package is in ok to insulate
BLD-Framing/Rough-in12/1/200512/2/200512/5/2005APART
DetailsDave Hannah
derick; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
BLD-Framing/Rough-in10/25/200510/26/200510/26/2005APART
DetailsMike Jordan
derick; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Shear wall nailing ok. Verified installation of all perimeter holdowns and strapping. Will need engineering for interioir floor to floor holdowns were no wall adove exists for connection.
BLD-Foundation7/20/20057/21/20057/21/2005APART
DetailsTony Young
Scheduled by a contractor via Hello! on 7/20/2005 at 5:24:57 PM. Contact: ###-####.
wip,,,, 80%
BLD-Footing7/8/20057/8/20057/8/2005PPART
DetailsDave Hannah
derrick ###-#### ok per Jim Wylie for garage footing only//footing pour shall be in compliance with Strata letter dated 7/7/05
PubWorks Subgrade Approval5/26/20055/26/20057/8/2005 PASS
footing subgrade for garage area approved by the geotechnical engineer with conditions: 1) limited areas measuring 3 by 6 feet and 2 by 2 feet in the east side of the garage footing trench will require over excavation of 4 inches of loose soil prior to pouring the footings. 2) The step down to the footing at the front of the garage has areas at each end that will be hand excavated to remove the loose soil to a depth of about 14 inches. These areas that will be over-excavated to native undisturbed soil will be filled with additional concrete
Override - Activity Holds  7/8/2005  
BLD-Footing6/17/20056/20/20056/20/2005APART
DetailsDave Hannah
###-#### brad//re-bar inspection in storage area please ok to form
Override - Activity Holds  6/17/2005  
BLD-Footing6/6/20056/7/20056/7/2005APART
DetailsDave Hannah
brad cooper; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie-- for the underground storage area ok to place concrete for ftgs in storage area
Override - Activity Holds1/1/19001/1/19006/6/2005  
per rita ok for customer to do this insp for the under ground storage area
Override - Activity Holds  6/6/2005  
PubWorks Subgrade Approval3/18/20053/18/20055/26/2005 PASS
The footing subgrade for the below grade storage area is acceptable. Placement of footings in this area can proceed. The footing subgrade for the below grade garage is not approved yet.

A letter from the applicant's geotechnical engineer indicating that the footing subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Terry Records at ###-####

Override - Activity Holds  3/22/2005  
Issue PAID IN FULL permit  3/22/2005 DONE
Plan assigned to (PEP)3/18/2005 3/21/2005 PASS
3/21/2005 08:48:45 PEP - activity updated through activity BLDA022 from case BLD05-00725.
Case Summary (BLD)  3/21/2005  
PLANS/APPL TAKEN TO FRONT DESK  3/21/2005 DONE
Override - Activity Holds  3/21/2005  
Inspection Record Card- Bld  3/21/2005 DONE
Override - Activity Holds  3/21/2005  
Permit Ready to Issue  3/21/2005  
Telephone call  3/21/2005 DONE
tlk to robert cooper construction ###-#### that permit and fees are ready to be picked up
Case Summary (BLD)  3/18/2005  
Override - Activity Holds  3/18/2005  
Inspection Record Card- Bld  3/18/2005  
Routing - Erosion and Sediment3/18/2005 3/18/2005 PASS
for hillside approval
ESC plan approved with attached conditions.
Application received  3/18/2005  
Routing - PLANNING3/18/2005