Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD05-01119
StatusFinaled
Name EKC INC
Site Address 1270 S VINNELL WAY
Project Name 
Customer Number 
ePlanReviewNo
Description
(PAUL MITCHELL/SCOT LEWIS SCHOOLS) Remodel to an existing 13,906 sq. ft. building for a new beauty school tenant to occupy the entire building per approved plans. There will be an assembly classroom/multi-use area within the space. Work to include interior demolition work, new 2-hour rated fire barrier walls to comply with the fire area for an A-3 Occupancy, some new 90 minute rated doors and 2-hour rated fire dampers in 2-hour rated fire barrier walls, new interior walls and doors, some new interior sidelights, some new exterior doors and a window, new exterior wall infill in former door openings, interior finish, new cabinets/counters, new sinks, fire alarm work, mechanical work including three additional rooftop HVAC units, plumbing work, and electrical work. A Certificate of Occupancy is to be issued when completed and approved. NOTE: This building is not fire sprinklered. JCB
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
CHANGE STATUS TO (FNL)  8/4/2006  
BLD-Aging Inspection8/1/20068/1/20068/1/2006 CANC
DetailsMike Jordan
BLD-Aging Inspection5/10/20065/10/20065/10/2006 CANC
DetailsMike Jordan
DOC - Permit Finaled5/10/20065/10/20065/10/2006PDONE
DetailsMike Jordan
BLD-Final1/26/20061/27/20061/27/2006PPASS
DetailsMike Jordan
Paul; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. ok for perm occ.
BLD-Final11/28/200511/28/200511/28/2005PPEND
DetailsMike Jordan
paul ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie. Still needs final on mech. Temp occ given. Still need to inspect glass in doors when they arrive, additional boots required under lavatory sinks for ADA and some additinal door hardware needs to be removed.
FIRE-Final Inspection11/23/200511/28/200511/28/2005APASS
DetailsForrest France
Fire life safety issues are satisfactory, c/n items have been completed, inspection passed.
BLD-Final11/21/200511/22/200511/22/2005PCANC
DetailsMike Jordan
Scheduled by a contractor via Hello! on 11/21/2005 at 1:28:45 PM. Contact: ###-####. Needs life/safety.
FIRE-Final Inspection11/21/200511/22/200511/22/2005ACANC
DetailsTroy Cobbley
No time for inspection
FIRE-Final Inspection11/17/200511/18/200511/18/2005AFAIL
DetailsTroy Cobbley
Provide exit signs and emergency lights as marked on sheet E2.1L, provide approved door hardware on both the interior and exterior keyed/deadbolted doors, provide occupandt load sign, provide braille exit signs per plans, provide the correct remote annunciators and test the duct smoke detectors
BLD-Final11/17/200511/18/200511/18/2005PNR
DetailsMike Jordan
Scheduled by a contractor via Hello! on 11/17/2005 at 12:01:30 PM. Contact: ###-####. Elec. final failed.
BLD-Other11/15/200511/15/200511/15/2005PPASS
DetailsMike Jordan
Scheduled by a contractor via Hello! on 11/15/2005 at 8:26:17 AM. Contact: ###-####. Ceiling grid insp. ok need elec and mech insp before placing tile.
BLD-Framing/Rough-in10/26/200510/26/200510/26/2005PPASS
DetailsTom Arcoraci
BLD-Framing/Rough-in10/25/200510/26/200510/26/2005ACANC
DetailsTom Arcoraci
PAUL; Phone #: ###-#### nOTE: Please call 1/2 hr prior to inspection Internet Inspection Request from: Cathy Chiles
BLD-Framing/Rough-in9/14/20059/15/20059/15/2005PPART
DetailsTom Arcoraci
ceiling cover inspection please////rick; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
BLD-Framing/Rough-in8/30/20058/31/20058/31/2005PPART
DetailsTom Arcoraci
partial framing///rick; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa 2 hr wall ok
BLD-Framing/Rough-in8/15/20058/16/20058/16/2005PPART
DetailsTom Arcoraci
rick; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa partial cover ok rear and freeway side
Issue PAID IN FULL permit  7/5/2005  
Telephone call  7/1/2005 DONE
lft ms with lou starita ###-####
Routing - PLAN CHECK6/24/2005 6/27/2005 PASS
Plans and permit approved and taken to front desk.
PLANS/APPL TAKEN TO FRONT DESK  6/27/2005 PASS
Inspection Record Card- Bld  6/27/2005 DONE
Print Occupancy Form  6/27/2005 DONE
Permit Ready to Issue  6/27/2005 DONE
Plan assigned to (JCB)5/3/2005 6/27/2005 PASS
6/27/2005 08:25:16 JCB - activity updated through activity BLDA022 from case BLD05-01119.
Routing - FIRE6/17/2005 6/24/2005 FAIL
Inconsistency between mechanical and electrical for code requirements on the dampers that penetrate the 2 hour fire barrier wall.
Additional plans submitted  6/24/2005 DONE
Received sketch (SK-1) from electrical engineer for clarification of penetration protection through the 2 hour fire barrier wall.
Routing - FIRE6/24/2005 6/24/2005 PASS
E-mailed IFC review comments to Julie Comstock at BRS.
Plan resubmittals received  6/17/2005 DONE
Small resubmittal addendum sheets received via e-mail in pdf format. Printed and attached to plans. Also red-lined on plan sheets.
Routing - PLAN CHECK6/8/2005 6/17/2005 PEND
When approved by Fire Department permit can be issued. Resubmittal plans to route to Fire Department for review.
Telephone call  6/16/2005 DONE
Called Julie Comstock of BRS Architects to discuss a few issues. Some issues will be clarified/red-lined on plans and others will need to be addressed/clarified on small addendum sheets.
Plan resubmittals received  6/9/2005  
Received (2) copies of sheet G01.1, SD1.1, A1.1, A1.2, A2.1, A6.0, A6.1, A8.1, A8.2, A9.1, A9.2, M1.0, M2.1, M2.2, M2.3, M3.1, M3.2, M3.3, M4.0, E0.0, E2.0D, E2.1F, E2.1L, E2.1P, E2.1MP, E2.1S, E3.0, E3.1, E3.2, E3.4, E3.5 and E3.6. Routed to Jason B.
1st review completed  6/8/2005 FAIL
failed plan check and fire.
Routing - FIRE6/1/2005 6/8/2005 FAIL
review faxed to architect.
Routing - PLUMBING5/31/2005 6/1/2005 PASS
Approved as noted for equipment and fixture connection verification with plumbing inspector and united water verification at final plumbing inspection, and plan and 2003 UPC.
Plan resubmittals requested  5/31/2005 DONE
Plan resubmittals and written response required for further review.
Routing - PLAN CHECK5/5/2005 5/31/2005 FAIL
Plan review e-mailed and faxed to architect. Plan resubmittals and written response required for further review. Plans to route to Plumbing and Fire Departments.
Routing - PLANNING5/3/2005 5/5/2005 PASS
Use approved per CUP97-63 and site-building improvements per DRH97-00135.
Routing - PUBLIC WORKS5/3/2005 5/3/2005 PASS
Routing - Erosion and Sediment5/3/2005 5/3/2005 PASS
ESC waiver request approved with attached conditions.
Plans ACCEPTED BY PLAN TECH  4/28/2005  
Application received  4/27/2005  
Recd Pcfee & Taken To Pln CK  4/27/2005  
Fee Review-notes4/27/20054/27/2005