BLD-Final | 4/26/2007 | 4/26/2007 | 4/26/2007 | P | PASS |
Tony Young
|
|
|
Anthony; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
|
DOC - Permit Finaled | 4/26/2007 | 4/26/2007 | 4/26/2007 | P | PASS |
Tony Young
|
|
|
c of o issued
|
BLD-Grading Inspection | 3/8/2007 | 3/8/2007 | 3/8/2007 | | DONE |
|
|
|
Final grading and drainage approved.
|
BLD-Framing/Rough-in | 3/15/2006 | 3/15/2006 | 3/15/2006 | P | DONE |
Tom Arcoraci
|
|
|
Anthony -- for shear panel; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong ok is by 415
|
BLD-Energy code compliance | 12/22/2005 | 12/22/2005 | 12/22/2005 | P | PASS |
Jim Sly
|
|
|
anthony; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
|
BLD-Framing/Rough-in | 12/22/2005 | 12/22/2005 | 12/22/2005 | P | PASS |
Jim Sly
|
|
|
anthony; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
|
BLD-Framing/Rough-in | 12/15/2005 | 12/15/2005 | 12/15/2005 | P | PART |
Tony Young
|
|
|
camil; Phone #: ###-#### Internet Inspection Request from: Barbara Moore shear ok,, c/n still posted but ok to insulate
|
BLD-Conference | 12/2/2005 | 12/2/2005 | 12/2/2005 | P | PART |
Tony Young
|
|
|
anthony ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie met w/ framer and super,, need to do per plans or get structural engineer on site to ok or design fix,, tall walls floor deck delaminate,, etc.
|
BLD-Framing/Rough-in | 11/22/2005 | 11/22/2005 | 11/22/2005 | P | FAIL |
Tony Young
|
|
|
anthony; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa c/n posted,, 2 pages,, reinspection fee imposed,, do not cover anything, or insulate
|
Stop Work/Reinspection Fee | 11/22/2005 | 11/22/2005 | 11/22/2005 | P | FAIL |
Tony Young
|
|
|
anthony; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
|
BLD-Framing/Rough-in | 11/15/2005 | 11/15/2005 | 11/15/2005 | P | NR |
Tony Young
|
|
|
anthony; Phone #: ###-#### Internet Inspection Request from: Barbara Moore too many things,, conf. only,, recall
|
BLD-Foundation | 7/29/2005 | 7/29/2005 | 7/29/2005 | P | PART |
Tony Young
|
|
|
dan; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD-Footing | 7/28/2005 | 7/28/2005 | 7/28/2005 | P | PASS |
Tom Arcoraci
|
|
|
ben ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
PubWorks Subgrade Approval | 6/2/2005 | 6/2/2005 | 7/28/2005 | | DONE |
|
|
|
Footing subgrade approved by geotech. 7/28/05
A letter from the applicant's geotechnical engineer indicating that the footing subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Terry Records at ###-####.
|
Plan assigned to (SRZ) | 6/24/2005 | 6/24/2005 | 6/29/2005 | | PASS |
|
|
|
6/29/2005 08:29:29 SRZ - activity updated through activity BLDA022 from case BLD05-01437.
|
Plan assigned to (SAM) | 5/31/2005 | 5/31/2005 | 6/29/2005 | | PASS |
|
|
|
6/29/2005 08:29:29 SRZ - activity updated through activity BLDA022 from case BLD05-01437.
|
Routing - PLAN CHECK | | | 6/29/2005 | | PASS |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 6/29/2005 | | DONE |
|
|
|
one set red-lined
|
Override - Activity Holds | | | 6/29/2005 | | |
|
|
|
|
Inspection Record Card- Bld | | | 6/29/2005 | | DONE |
|
|
|
|
Override - Activity Holds | | | 6/29/2005 | | |
|
|
|
|
Permit Ready to Issue | | | 6/29/2005 | | DONE |
|
|
|
|
Override - Activity Holds | | | 6/29/2005 | | |
|
|
|
|
Inspection Record Card- Bld | | | 6/29/2005 | | |
|
|
|
|
Telephone call | | | 6/29/2005 | | DONE |
|
|
|
called CSC, told him permit is ready and fees
|
Override - Activity Holds | | | 6/29/2005 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 6/29/2005 | | DONE |
|
|
|
|
Print Occupancy Form | | | 6/29/2005 | | DONE |
|
|
|
|
Plan resubmittals received | | | 6/28/2005 | | |
|
|
|
Received (2) copies of sheet 2 and (3) copies of supporting structural calcs. Routed to Sam Z.
|
Case Summary (BLD) | | | 6/27/2005 | | |
|
|
|
|
Plan Reviewer's activity | | | 6/24/2005 | | PASS |
|
|
|
Pending Tall wall Engineering, and structural calcs. from Architect. I spoke with the Architect on 06/24/05 and requested.
(SRZ) Recieved Tall Wall Engineering and new Foundation sheet. (SRZ)
|
Routing - Erosion and Sediment | 6/6/2005 | | 6/7/2005 | | PASS |
|
|
|
ESC plan approved with attached conditions.
|
Routing - FIRE | 6/7/2005 | | 6/7/2005 | | PASS |
|
|
|
This house requires an NFPA 13D automatic fire sprinkler system, modified by the installation of a single row of dry sidewall sprinklers along the wall common to attached garages and the living space. (Quail Ridge, 8 sub.)
|
Routing - PLANNING | 6/2/2005 | | 6/6/2005 | | PASS |
|
|
|
passed Monday 6/6/05
|
Routing - PUBLIC WORKS | 6/2/2005 | | 6/2/2005 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS GRADING | 5/31/2005 | | 6/2/2005 | | PASS |
|
|
|
Approved as Category 3
|
Application received | | | 5/31/2005 | | |
|
|
|
|