Permit NumberBLD05-01615
StatusFinaled
Name FALASH & ROSS CONSTRUCTION
Site Address 380 E PARKCENTER BLVD
Project Name 
Customer Number 
ePlanReviewNo
Description
**(Common Area Improvements)** This permit is to remodel corridor areas with new finishes and new lighting. Currently the fire sprinkler heads are being changed out on the first and second floors under a separate permit to quick response heads, the third floor has already installed quick response heads. This will eliminate the requirement for one-hour rated corridors. There will still be the requirement for a one-hour exit passage way from the west stair enclosure to the exterior exit door. The east stair enclosure may exit through a fully fire sprinklered lobby area. This building is fully fire sprinklered for one hour substitution: All alterations and modifications to the sprinkler system shall be per NFPA #13 as regulated by the fire department. *RMH*
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice BLD12/28/200512/28/20051/3/2006 DONE
Second Notice has not been responded to.
Second Notice BLD12/5/200512/5/200512/28/2005 DONE
First Notice has not been responded to.
First Notice11/22/200511/22/200512/5/2005 DONE
DetailsDave Hannah
BLD-Final11/22/200511/22/200511/22/2005PPASS
DetailsDave Hannah
gill///please call 30 min prior to meet you; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
DOC - Permit Finaled11/22/200511/22/200511/22/2005PPASS
DetailsDave Hannah
cert of comp issued
FIRE-Final Inspection11/18/200511/18/200511/18/2005PPASS
DetailsForrest France
Fire life safety is satisfactory.
BLD-Aging Inspection10/12/200510/12/200510/12/2005 PASS
DetailsJim Storey
wip
BLD-Framing/Rough-in8/10/20058/11/20058/11/2005PPART
DetailsDave Hannah
1st floor lobby only ceiling grid inspection please///gill; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok to cover lobby area
BLD-Framing/Rough-in7/15/20057/18/20057/18/2005APASS
DetailsJim Storey
COVER UP INSPECTION PLEASE//Please call him after inspection so he can contact the drywall guy///bob; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
Issue PAID IN FULL permit  6/20/2005 DONE
Plan assigned to (R_H)6/17/2005 6/17/2005 PASS
6/17/2005 09:01:36 RMH - activity updated through activity BLDA022 from case BLD05-01615.
Routing - PLAN CHECK6/17/2005 6/17/2005 PASS
Routed plans to the fire department, 6/17/05, Permit pending fire departments review.
Case Summary (BLD)  6/17/2005 DONE
Routing - FIRE6/17/2005 6/17/2005 PASS
Spoke with Bill Alexander about this permit. He indicated that there is a fire sprinkler permit for the first & second floors, and that he did not have to see these plans. Field verify by inspector.
PLANS/APPL TAKEN TO FRONT DESK  6/17/2005 DONE
Permit Ready to Issue  6/17/2005 DONE
Inspection Record Card- Bld  6/17/2005 DONE
Telephone call  6/17/2005 DONE
tlk to bob ross ###-#### that permit and fees are ready to be picked up
1st review completed  6/17/2005 PASS
1st review completed  6/17/2005 PASS
Recd Pcfee & Taken To Pln CK  6/16/2005  
Plans ACCEPTED BY PLAN TECH  6/16/2005  
Application received  6/15/2005  
Fee Review-notes6/16/20056/16/2005