(F) Reprint permit | | | 10/5/2006 | | |
|
|
|
|
BLD-Final | 4/6/2006 | 4/6/2006 | 4/6/2006 | P | PASS |
Mike Jordan
|
|
|
Scott Simpson; Phone #: ###-#### Internet Inspection Request from: Scott Simpson
|
DOC - Permit Finaled | 4/6/2006 | 4/6/2006 | 4/6/2006 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Final | 1/31/2006 | 1/31/2006 | 1/31/2006 | P | CANC |
Mike Jordan
|
|
|
brian blazer; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
|
BLD-Energy code compliance | 1/31/2006 | 1/31/2006 | 1/31/2006 | P | PASS |
Mike Jordan
|
|
|
brian blazer; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa. All framing issues have been resolved. ok to cover.
|
BLD-Energy code compliance | 1/30/2006 | 1/30/2006 | 1/30/2006 | P | FAIL |
Mike Jordan
|
|
|
Brian; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Complete lateral bracing, header required over opening at C1 truss bearing, justify girder truss support were hangar was deleted. L brace gable end.
|
BLD-Framing/Rough-in | 1/26/2006 | 1/27/2006 | 1/27/2006 | A | PART |
Mike Jordan
|
|
|
Scott; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Trusses repaired as to not penetrate the 1hr wall membrane. Reveiwed truss engineering for repaires on cut trusses, girder truss repaired incorrectly. Needs to complete lateral bracing, remove remaining wood penetrations from 1hr wall. All non rated boxes were removed and replaced with rated 1hr boxes. ok to insulate. c/n posted.
|
BLD-Framing/Rough-in | 1/23/2006 | 1/24/2006 | 1/24/2006 | A | FAIL |
Mike Jordan
|
|
|
Scott -- call 1st before insp; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Must install rated boxes at waterline and gasline. B vent penetration not allowed thru laydown parapet. Membrane penetration with wood trusses not allowed. not per plans.
|
BLD-Conference | 1/23/2006 | 1/24/2006 | 1/24/2006 | A | CANC |
Tom Arcoraci
|
|
|
Scott -- call 1st before insp; requesting both Tom Arcoraci and Mike Jordan for framing insp and conference; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
|
BLD-Framing/Rough-in | 1/17/2006 | 1/17/2006 | 1/17/2006 | P | NR |
Tom Arcoraci
|
|
|
scott ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie needs app plans
|
BLD-Framing/Rough-in | 1/13/2006 | 1/13/2006 | 1/13/2006 | P | NR |
Mike Jordan
|
|
|
brian; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa. No truss engineering.
|
BLD-Framing/Rough-in | 1/10/2006 | 1/10/2006 | 1/10/2006 | P | FAIL |
Mike Jordan
|
|
|
scott; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie. Needs to provide approved plans and truss engineering. Provide blow back patches at rated wall were holes were made. c/n posted.
|
BLD-Foundation | 9/12/2005 | 9/12/2005 | 9/12/2005 | P | PART |
Tom Arcoraci
|
|
|
ruben; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD-Footing | 9/6/2005 | 9/6/2005 | 9/6/2005 | P | PART |
Tom Arcoraci
|
|
|
michael ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie wip ok
|
Telephone call | | | 8/9/2005 | | DONE |
|
|
|
called ###-#### (pepperwood homes) told him have a permit ready and hung up. Did not tell fees and didn't give name.
|
Issue PAID IN FULL permit | | | 8/9/2005 | | DONE |
|
|
|
|
Plan assigned to (SRZ) | 8/8/2005 | 8/8/2005 | 8/8/2005 | | PASS |
|
|
|
8/8/2005 14:14:07 SRZ - activity updated through activity BLDA022 from case BLD05-01833.
|
Plan assigned to (SAM) | 7/7/2005 | 7/7/2005 | 8/8/2005 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 7/12/2005 | | 8/8/2005 | | PASS |
|
|
|
|
Case Summary (BLD) | | | 8/8/2005 | | |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/8/2005 | | DONE |
|
|
|
one set red-lined
|
Inspection Record Card- Bld | | | 8/8/2005 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 8/8/2005 | | DONE |
|
|
|
|
Routing - PLANNING | 7/12/2005 | | 7/12/2005 | | PASS |
|
|
|
|
Routing - PLANNING | 7/7/2005 | | 7/12/2005 | | FAIL |
|
|
|
routed to Carl Miller per 79-6-PDR (Ada approval). eeg.
Failed: site plans do not match floor plans
|
Routing - PUBLIC WORKS | 7/12/2005 | | 7/12/2005 | | PASS |
|
|
|
|
Application received | | | 7/7/2005 | | |
|
|
|
|