Permit Information
Permit NumberBLD05-01937
StatusFinaled
Name GOLIS CONSTRUCTION
Site Address 8485 W USTICK RD
Project NameFIRE STATION #4
Customer Number 
ePlanReviewNo
Description
(FIRE STATION #4) This building will be fire sprinklered as part of this project. To remodel an existing 3,929 square foot fire station. Work is to include new roof insulation and membrane, interior nonbearing walls, wall furring at exterior walls, three toilet/shower rooms (toilet and basin within one toilet room to be accessible to the disabled), suspended ceilings, millwork, and interior finishes. The work shall comply with the approved drawings, the plan review report, and all applicable codes. The fire sprinkler system shall comply with NFPA 13 as regulated by the Fire Department. A separate zoning approval will be required for the temporary modular structure for housing personnel until the remodel is complete. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice BLD8/18/20068/18/20068/25/2006 DONE
Second Notice has not been responded to.
Second Notice BLD8/2/20068/2/20068/18/2006 DONE
First Notice has not been responded to.
First Notice 7/18/20068/2/2006 DONE
Permanent occupancy  7/18/2006 DONE
Perm. Occ. Cert. # 11127 issued 7-18-06 to Fire Station #4.
BLD-Final7/6/20067/7/20067/7/2006PPASS
DetailsTony Young
Scheduled by a contractor via Hello! on 7/6/2006 at 4:25:45 PM.
ok for c of o
FIRE-Final Inspection7/6/20067/7/20067/7/2006APASS
DetailsTroy Cobbley
Life safety finaled
BLD-Framing/Rough-in7/5/20067/6/20067/6/2006APASS
DetailsTom Arcoraci
rudie - ceiling grid; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley done by 316
Code Occupancy Approval6/29/20066/29/20066/29/2006PPASS
DetailsCarol Montgomery
BLD-Framing/Rough-in6/28/20066/29/20066/29/2006AFAIL
DetailsJim Sly
rudy - ceiling and structural; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
Need seismic splay wires, strut, Perim wires, spacer bars
Permanent Occupancy 6/29/20066/29/2006 DONE
Details
BLD-Energy code compliance5/10/20065/12/20065/12/2006PPASS
DetailsJim Sly
rudy; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
BLD-Framing/Rough-in5/3/20065/4/20065/4/2006PPASS
DetailsJim Sly
rudy; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
BLD-Aging Inspection3/10/20063/10/20063/10/2006 DONE
DetailsJim Sly
WIP
Issue PAID IN FULL permit  11/29/2005 DONE
Print Occupancy Form  11/8/2005 DONE
Permit Ready to Issue  11/8/2005 DONE
Telephone call  11/8/2005 DONE
called ###-#### and left voicemessage for Stillman that permit is ready but need GC and breakdown of values before issue
Plan assigned to (CJW)7/19/2005 11/7/2005 PASS
11/7/2005 12:47:09 CJW - activity updated through activity BLDA022 from case BLD05-01937.
Routing - PLANNING10/25/2005 11/7/2005 PASS
Temporary modular must be removed by December 20, 2005.
Routing - PLAN CHECK11/7/2005 11/7/2005 SONE
PLANS/APPL TAKEN TO FRONT DESK  11/7/2005 DONE
Routing - FIRE10/11/2005 10/25/2005 PASS
resubmittal acceptable.
Routing - PLAN CHECK8/17/2005 10/11/2005 PASS
(9-30-05) The emergency excape and rescue openings have not been provided for the sleeping rooms. Architect E-mailed that this needed to be resolved. (10/11/05) Drawings approved after resubmittal review.
Plan resubmittals received  10/11/2005  
Received (2) copies of sheet A0.1, A1.2, A1.3 and P1.1. Routed to Carl W.
Plan resubmittals received  9/23/2005  
Received (2) copies of sheet A1.2, A1.3, A3.1, A5.1 and A6.1. Also received (2) sets of structural calcs. Routed to Carl W.
Routing - FIRE8/9/2005 8/17/2005 FAIL
review comments faxed to architect.
1st review completed  8/17/2005 FAIL
failed planning, plan check and fire.
Routing - PLAN CHECK7/20/2005 8/9/2005 FAIL
The IBC plan review was started on August 5, 2005 and was finished on August 9. Revised drawings were required. See the plan review report.
Routing - PLANNING7/19/2005 7/20/2005 FAIL
Evelyn or Colleen
Need to apply for a CU mod first!
Routing - PUBLIC WORKS7/19/2005 7/19/2005 PASS
Plans ACCEPTED BY PLAN TECH  7/18/2005  
When bidding is finalized and a contractor is selected he (she) will be required to obtain an ESC permit prior to starting the work per Steve Webb. (msouthard)
Application received  7/15/2005  
Fee Review-notes7/15/20057/15/2005