Permit Information
Permit NumberBLD05-01943
StatusFinaled
Name STATUS HOMES INC
Site Address 2311 S RUSHMORE CT
Project Name 
Customer Number 
ePlanReviewNo
Description
To construct a 2509 sq. ft. two story single family dwelling with a 623 sq. ft. attached two car garage, a 160 sq. ft. covered concrete entry porch and a 304 sq. ft. concrete patio at rear of structure per approved plans and attached condition list."The permit holder is responsible to comply with current wall bracing requirements as adopted by Boise City." THIS LOT IS WITHIN THE FLOODPLAIN AREA. A Elevation Certificate is required before calling for a rough framing inspection. (1st floor 1586 sq. ft.)(2nd floor 923 sq. ft.) R-1B CUP#03-00074 DJO
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  5/14/2008 DONE
BLD-Final5/2/20065/3/20065/3/2006PPASS
DetailsMike Jordan
Garage open push up on door. Or use code 991 enter Internet Inspection Request from: Carey Allen
DOC - Permit Finaled5/3/20065/3/20065/3/2006PPASS
DetailsMike Jordan
BLD-Final4/13/20064/14/20064/14/2006PNR
DetailsMike Jordan
Internet Inspection Request from: Carey Allen. Needs plumbing final.
BLD-Energy code compliance2/6/20062/7/20062/7/2006PPASS
DetailsJim Storey
Internet Inspection Request from: Carey Allen
BLD-Energy code compliance2/3/20062/3/20062/3/2006PNR
DetailsMike Jordan
BLD-Energy code compliance2/2/20062/3/20062/3/2006ACANC
DetailsMike Jordan
Internet Inspection Request from: Carey Allen
Plan Reviewer's activity  2/3/2006 PASS
Elevation Certificate recieved and approved by Jim W. Framing inspection can be performed.
BLD-Framing/Rough-in2/2/20062/3/20062/2/2006PCANC
DetailsMike Jordan
Internet Inspection Request from: Carey Allen Inspection cancelled from web by: Carey Allen
BLD-Framing/Rough-in2/2/20062/2/20062/2/2006PFAIL
DetailsMike Jordan
CERT. HAS BEEN SENT. ; Phone #: ###-#### Internet Inspection Request from: Carey Allen. Confirmed with Jim Wylie that elev cert has been received. Repair cut wall studs at air duct in garage. ok to insulate.
BLD-Framing/Rough-in1/28/20062/1/20062/2/2006PFAIL
DetailsTom Arcoraci
Internet Inspection Request from: Carey Allen c/notice posted
BLD-Foundation10/27/200510/31/200510/31/2005APART
DetailsTom Arcoraci
Scheduled by a contractor via Hello! on 10/27/2005 at 9:17:06 AM. Contact: ###-####.
BLD-Footing10/27/200510/27/200510/27/2005PPART
DetailsTom Arcoraci
Scheduled by a contractor via Hello! on 10/27/2005 at 9:16:41 AM. Contact: ###-####.
Issue PAID IN FULL permit  9/30/2005 DONE
Telephone call  9/28/2005  
called ###-#### and told Kim permit is ready, she did not want to know fees
PLANS/APPL TAKEN TO FRONT DESK  9/27/2005 DONE
rcd from djo 9/26/2005
Inspection Record Card- Bld  9/27/2005 DONE
Permit Ready to Issue  9/27/2005 DONE
Case Summary (BLD)  9/26/2005  
Plan assigned to (SAM)7/18/20057/18/20059/23/2005 DONE
Routing - PLANNING9/7/2005 9/9/2005 PASS
Routed to Carl Miller per CUP03-00074
Routing - PUBLIC WORKS9/6/2005 9/7/2005 PASS
Plan resubmittals received  9/6/2005  
Received new plan submittal to meet flood plain requirements.
Plan Reviewer's activity  8/25/2005  
Applicant picked up Plans & Application to make revisions. Applicant will resubmit under same BLD number.
Routing - PUBLIC WORKS8/19/2005 8/22/2005 FAIL
Plans failed by Jim Wylie, contact# ###-####.
Flood plain requirements.
Routing - PLANNING8/19/2005 8/19/2005 PASS
redlined plans and sent on - adjust building footprint 7' to east to meet 20' setback street side. Single story on east side for 5' minimum setback.
Application received  7/18/2005  
Routing - PLANNING7/28/2005   FAIL
street side setback
Routing - PLAN CHECK9/7/2005    
Plan assigned to (DJO)9/23/2005