BLD-Final | 8/8/2007 | 8/9/2007 | 8/9/2007 | A | PASS |
Tony Young
|
|
|
brian Phone #: ###-####
|
DOC - Permit Finaled | 8/9/2007 | 8/9/2007 | 8/9/2007 | P | PASS |
Tony Young
|
|
|
c of o issued
|
BLD-Grading Inspection | 8/9/2007 | 8/9/2007 | 8/9/2007 | | DONE |
|
|
|
Final grading and drainage approved
|
BLD-Final | 8/2/2007 | 8/3/2007 | 8/3/2007 | A | NR |
Tony Young
|
|
|
brian Phone #: ###-#### need trades and hill side
|
BLD-Framing/Rough-in | 5/8/2006 | 5/8/2006 | 5/8/2006 | P | PASS |
Tony Young
|
|
|
brian Note: cover; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD-Energy code compliance | 5/8/2006 | 5/8/2006 | 5/8/2006 | P | PASS |
Tony Young
|
|
|
brian Note: cover; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD-Framing/Rough-in | 4/27/2006 | 4/28/2006 | 4/28/2006 | A | PART |
Tony Young
|
|
|
Call first ; Phone #: ###-#### Internet Inspection Request from: Rita DeYoung strap plates, point load studs,, fire blocks,, ok to insulate
|
BLD-Framing/Rough-in | 4/18/2006 | 4/19/2006 | 4/19/2006 | A | FAIL |
Tony Young
|
|
|
Brian; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong need trades 1st
|
BLD-Framing/Rough-in | 3/29/2006 | 3/29/2006 | 3/29/2006 | P | PART |
Tony Young
|
|
|
Josh ph ###-#### exterior shear ok,, straps on exterior ok
|
BLD-Framing/Rough-in | 3/28/2006 | 3/29/2006 | 3/29/2006 | A | CANC |
Tony Young
|
|
|
joshua; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa meeting,, no time,, rescheduled for pm
|
BLD-Framing/Rough-in | 2/8/2006 | 2/9/2006 | 2/10/2006 | A | PART |
Tony Young
|
|
|
Joshua -- for sheeting/shearing; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong exterior ok to cover w/ house wrap,, nailing is ok,, straps are being reviewed for proper method on how engineer has designed
|
BLD-Framing/Rough-in | 2/2/2006 | 2/3/2006 | 2/3/2006 | A | NR |
Tony Young
|
|
|
Brian; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong conf only,, lots of details on engineering
|
BLD-Foundation | 9/12/2005 | 9/13/2005 | 9/13/2005 | A | PART |
Mike Jordan
|
|
|
cal; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD-Footing | 9/12/2005 | 9/12/2005 | 9/12/2005 | P | NR |
Tony Young
|
|
|
cale; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD-Foundation | 9/6/2005 | 9/7/2005 | 9/7/2005 | A | PART |
Tony Young
|
|
|
bob; Phone #: ###-#### Internet Inspection Request from: Barbara Moore basement walls
|
BLD-Footing | 9/1/2005 | 9/1/2005 | 9/1/2005 | P | PART |
Tony Young
|
|
|
Cal; Phone #: ###-#### Internet Inspection Request from: Barbara Moore wip
|
PubWorks Subgrade Approval | 7/20/2005 | 7/20/2005 | 8/30/2005 | | PASS |
|
|
|
Footing subgrade approved for crawlspace and patial basement.
A letter from the applicant's geotechnical engineer indicating that the footing subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Terry Records at ###-####.
|
Plan assigned to (SRZ) | 8/15/2005 | 8/15/2005 | 8/19/2005 | | PASS |
|
|
|
8/19/2005 08:27:26 SRZ - activity updated through activity BLDA022 from case BLD05-01950.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/19/2005 | | DONE |
|
|
|
One set Red-lined.
|
Inspection Record Card- Bld | | | 8/19/2005 | | DONE |
|
|
|
|
Print Occupancy Form | | | 8/19/2005 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 8/19/2005 | | DONE |
|
|
|
|
Telephone call | | | 8/19/2005 | | DONE |
|
|
|
called Brian Sweet ###-#### and left voicemessage that permit is ready and fees
|
Issue PAID IN FULL permit | | | 8/19/2005 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 8/17/2005 | | 8/19/2005 | | PASS |
|
|
|
|
Plan Reviewer's activity | | | 8/18/2005 | | PASS |
|
|
|
Plan review Pending for Mechanical Ventilation Alternate Design. (SRZ)
|
Case Summary (BLD) | | | 8/18/2005 | | |
|
|
|
|
Routing - FIRE | 8/15/2005 | | 8/16/2005 | | PASS |
|
|
|
No fire sprinklers required - Arrowhead Ridge #1.
|
Plan assigned to (SAM) | 7/18/2005 | 7/18/2005 | 8/15/2005 | | DONE |
|
|
|
|
Routing - Erosion and Sediment | 8/15/2005 | | 8/15/2005 | | PASS |
|
|
|
ROUTED TO EROSION ON 8/15/05. (SRZ). ESC plan approved with attached conditions.
|
Routing - PUBLIC WORKS GRADING | 7/19/2005 | | 7/20/2005 | | PASS |
|
|
|
APPROVED AS CATEGORY 3
|
Routing - PUBLIC WORKS | 7/19/2005 | | 7/19/2005 | | PASS |
|
|
|
|
Routing - PLANNING | | | 7/19/2005 | | PASS |
|
|
|
|
Application received | | | 7/18/2005 | | |
|
|
|
|