BLD-Final | 9/29/2009 | 9/30/2009 | 9/30/2009 | A | PASS |
Dave Hannah
|
|
|
Steve Phone #: ###-####
|
DOC - Permit Finaled | 9/30/2009 | 9/30/2009 | 9/30/2009 | P | PASS |
Dave Hannah
|
|
|
|
BLD-Grading Inspection | 9/30/2009 | 9/30/2009 | 9/30/2009 | A | BOND |
Terry Records
|
|
|
Grading and drainage is conditionally approved upon receipt of $57,948.00 surety for rebuilding the keystone retaining walls that are failing. According to Vicki descalfani bond has been submitted.
|
Letter of compliance | | | 9/30/2009 | | DONE |
|
|
|
|
BLD-Final | 9/23/2009 | 9/24/2009 | 9/24/2009 | A | PART |
Dave Hannah
|
|
|
gary- after 9am Phone #: ###-#### c/n items complete but still needs hillside final or bond
|
BLD-Final | 9/11/2009 | 9/14/2009 | 9/14/2009 | A | FAIL |
Dave Hannah
|
|
|
Gary Phone #: ###-#### needs terry records final also needs to close up openings along sides of front steps on to deck ladder in window well and fire stop openings in garage
|
CHANGE STATUS TO (ISS) | | | 9/1/2009 | | DONE |
|
|
|
reopen permit
|
(F) Reprint permit | | | 9/1/2009 | | DONE |
|
|
|
|
Meeting | | | 8/25/2009 | | DONE |
Barbara Stitt
|
|
|
See case notes
|
BLD-Conference | 5/15/2007 | 5/15/2007 | 5/15/2007 | P | PASS |
Dave Hannah
|
|
|
|
(F) Reprint permit | | | 5/14/2007 | | DONE |
|
|
|
|
(F) Reprint permit | | | 5/14/2007 | | DONE |
|
|
|
|
PRINT Activities | | | 5/14/2007 | | |
|
|
|
|
PRINT Activities | | | 5/14/2007 | | DONE |
|
|
|
|
BLD-Energy code compliance | 8/17/2006 | 8/17/2006 | 8/18/2006 | P | DONE |
Dave Hannah
|
|
|
travis; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
|
BLD-Energy code compliance | 8/17/2006 | 8/18/2006 | 8/18/2006 | A | PASS |
Dave Hannah
|
|
|
travis; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok to cover
|
BLD-Framing/Rough-in | 8/1/2006 | 8/2/2006 | 8/2/2006 | A | FAIL |
Mike Jordan
|
|
|
travis; Phone #: ###-#### Note: please cal 1/2 hr prior to inspection Internet Inspection Request from: Cathy Chiles. Needs to fireblock above arches upstairs. ok to insul. c/n posted.
|
BLD-Framing/Rough-in | 7/27/2006 | 7/28/2006 | 8/1/2006 | A | FAIL |
Dave Hannah
|
|
|
travis - call 1/2 hr prior to meet there; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley needs to fire block
|
BLD-Other | 6/5/2006 | 6/6/2006 | 6/6/2006 | A | PASS |
Dave Hannah
|
|
|
TRAVIS nOTE: SHEAR WALL; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to cover ext walls
|
BLD-Framing/Rough-in | 5/22/2006 | 5/24/2006 | 5/24/2006 | A | FAIL |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 5/22/2006 at 12:02:33 PM. Contact: ###-####.shear walls needs tobe fixed
|
BLD-Foundation | 11/14/2005 | 11/15/2005 | 11/15/2005 | A | PART |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 11/14/2005 at 3:07:22 PM. Contact: ###-####.ok to place concrete after crew adds some #4 bar to retainning wall sections
|
BLD-Footing | 11/9/2005 | 11/10/2005 | 11/14/2005 | A | PASS |
Dave Hannah
|
|
|
bob eason; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
|
PubWorks Subgrade Approval | 11/9/2005 | 11/9/2005 | 11/9/2005 | | DONE |
|
|
|
Footing subgrade approved by the geotechnical engineer
|
Issue PAID IN FULL permit | | | 10/12/2005 | | DONE |
|
|
|
|
Plan assigned to (SRZ) | 10/5/2005 | 10/5/2005 | 10/11/2005 | | PASS |
|
|
|
10/11/2005 11:44:18 SRZ - activity updated through activity BLDA022 from case BLD05-02457.
|
Routing - FIRE | 10/11/2005 | | 10/11/2005 | | PASS |
|
|
|
Approved per resubmitted sheet A12 with annotation that a 13D fire sprinler system will be installed within the residence plus dry sidewall sprinklers along the garage walls which separate the garage from living spaces.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 10/11/2005 | | DONE |
|
|
|
ONE SET RED-LINED.
|
Inspection Record Card- Bld | | | 10/11/2005 | | |
|
|
|
|
Permit Ready to Issue | | | 10/11/2005 | | DONE |
|
|
|
|
Telephone call | | | 10/11/2005 | | DONE |
|
|
|
called ###-#### and left voicemessage that permit is ready and fees
|
Routing - PLAN CHECK | 10/11/2005 | | 10/11/2005 | | PASS |
|
|
|
|
Routing - Erosion and Sediment | 10/10/2005 | | 10/11/2005 | | |
|
|
|
ESC plan resubmittal approved with attached conditions.
|
Plan Reviewer's activity | | | 10/10/2005 | | PASS |
|
|
|
Plan review pending Engineer to stamp foundation sheet. I called Engineer and left message. (SRZ)
|
Case Summary (BLD) | | | 10/6/2005 | | |
|
|
|
|
Plan assigned to (SAM) | 9/2/2005 | 9/2/2005 | 10/5/2005 | | DONE |
|
|
|
|
Routing - FIRE | 9/14/2005 | | 9/23/2005 | | FAIL |
|
|
|
Approved Fire Department vehicle access roads shall be provided to within 150'-0" of all exterior portions of this building. All bridges, gates, public or private streets, individual or common driveways, or dedicated emergency vehicle access lanes, etc., which are considered "fire department vehicle access roads" shall have: a concrete or paved surface capable of supporting 70,000lbs. GVW and 24,000 lbs. per axle, a minimum of 20'-0" width, 48'-0" outside turning radius and 28'-0" inside radius, 13' 6" overhead clearance, and no dead ends over 150 feet unless an approved turnaround is provided. Dead-end roads in excess of 150' shall be provided with an approved area for turning around fire apparatus. Approved turnarounds shall be a cul-de-sac with an outside turning radius of 48', or of a "tee" or "Y" shape with 20' minimum width legs extending at least 65' from the centerline of the main roadway and having the required 28'inside/48'outside turning radii.(ref. IFC 503 and amendments per BMC 7-01-27 through 36).
NOTE: Resubmit a SCALED site plan showing a FD access lane and turnaround meeting the above criteria. Alternatively, provide approved fire sprinklers in accordance with NFPA 13D and including 1 row of sidewall sprinklers along the garage walls separating living spaces.
|
Plan resubmittals received | | | 9/14/2005 | | DONE |
|
|
|
Received 1 Transmittal,2 Stormwater Pollution Prevention Plans, & 2 Copys of sheet C2 . Inserted into plans and taken back to Fire(Sam R.)
|
Routing - Erosion and Sediment | 9/13/2005 | | 9/14/2005 | | FAIL |
|
|
|
ESC does not meet requiremens set forth in BMC 8-17. Checklist completed and faxed to PD.
|
Routing - PLANNING | 9/8/2005 | | 9/13/2005 | | PASS |
|
|
|
Must comply with all conditions of CFH05-00021 and must retain 3' landscape buffer between driveway and right side prop. line. AW
|
Routing - PUBLIC WORKS | 9/7/2005 | | 9/8/2005 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS GRADING | 9/2/2005 | | 9/7/2005 | | PASS |
|
|
|
Approved as category 1 by CFH05-00021
|
Application received | | | 9/2/2005 | | |
|
|
|
|
Routing - Erosion and Sediment | 10/10/2005 | | | | |
|
|
|
routed to ESC. Please route back to Sam Zahorka when done.
|