Permit Information
Permit NumberBLD05-02489
StatusFinaled
Name HILBERS INC
Site Address 1666 S ENTERTAINMENT AVE
Project NameFUDDRUCKERS RESTAURANT
Customer Number 
ePlanReviewNo
Description
(Fuddruckers Restaurant) To construct a 7,841 sq. ft. one story Type VB fully fire sprinkled restaurant. Other work includes all site improvements, paving and landscaping per approved plans and attachments, DR05-0233. Fire sprinklers used for area
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice BLD10/1/200710/1/20072/26/2009 DONE
DetailsPatricia Smith
Second Notice has not been responded to.
Telephone call  2/11/2008 DONE
lft vm with glenn hilbers ###-#### ext 118 at 2:00 regarding that I fax 4 final notices and havent heard from their company with the final notices
Second Notice BLD7/31/20077/31/200710/1/2007 DONE
First Notice has not been responded to.
First Notice 7/20/20077/31/2007 DONE
Permanent occupancy  7/20/2007 DONE
Code Occupancy Approval7/19/20077/19/20077/19/2007PPASS
DetailsScott M.Brown
finaly planted replacement trees final signed off
BLD-Final7/19/20077/19/20077/19/2007PPASS
DetailsMike Jordan
Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt. ok for perm occ.
Temporary occupancy  8/31/2006 DONE
Temporary occupancy extended until November 29, 2006. Landscaping issue with trees needs to be resolved. Extended per Jenifer Gilliland
BLD-Final8/28/20068/28/20068/28/2006PNR
DetailsMike Jordan
jack; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Still needs to bond for trees that have been removed, Still needs final from CDHD. Contacted contractor (Jack) to inform him that thr temp. occ. expires this Saturday and either needs to resolve issues or request an extension. Jack noted that he wuold contact the owner and inform him of issues.
BLD-Conference7/7/20067/7/20067/10/2006ADONE
DetailsMike Jordan
Met with fire dept. to go over issues from compliant. Contacted contractor and left message.
Case Summary (BLD)  7/7/2006 DONE
Code Occupancy Approval  6/6/2006 FAIL
THEY CUT AND REMOVED 3 MATURE TREES. THEY MUST BOND FOR THE TREES.
FIRE-Final Inspection6/5/20066/6/20066/5/2006APASS
DetailsTroy Cobbley
Life safety finaled
FIRE-Final Inspection6/2/20066/2/20066/2/2006PPART
DetailsTroy Cobbley
A temporary occupancy was given with Dave Hannimans permission until the correct covers are installed on the a/v's in the outdoor area. Life safety is ok to final when fire alarm is finaled.
Temporary occupancy  6/2/2006 DONE
Temp. Occ. Cert. # 5410 issued 6-2-06 to Fuddrucker's Restaurant.
FIRE-Final Inspection5/26/20065/30/20065/30/2006AFAIL
DetailsTroy Cobbley
Fire alarm permit needs to be finaled. When that is done then life safety can be signed off.
FIRE-Final Inspection5/25/20065/26/20065/26/2006AFAIL
DetailsForrest France
The project related fire sprinkler and alarm permits must be inspected and approved prior to life safety final approval. Informed general contractor of requirements and advised him to read the building permit fire code review notes and pretest before next inspection.
BLD-Final5/25/20065/26/20065/26/2006PPART
DetailsMike Jordan
jack; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. ok for temp occ if fire,life/safety signs. Also needs to install boots under sinks in bathrooms, grab bars not per plan.
Code Occupancy Approval Temp5/25/20065/25/20065/25/2006PDONE
DetailsScott M.Brown
SOME SMALL AMOUNT OF TRIM AND LANDSCAPE TO FINISH. I SIGNED TEMP OCCUPANCY DUE TO LOW DOLLAR AMOUNT TO BOND NOT MAKING THEM BOND.
BLD-Other5/24/20065/24/20065/24/2006PFAIL
DetailsMike Jordan
jack Note: t-bar; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Ceiling grid not per plan. Need letter from arch. or change grid so it is per plan.
BLD-Framing/Rough-in4/10/20064/11/20064/11/2006APASS
DetailsMike Jordan
Jack; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
BLD-Energy code compliance4/7/20064/10/20064/10/2006APASS
DetailsMike Jordan
Jack; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Perimeter walls.
BLD-Framing/Rough-in3/31/20064/3/20064/3/2006PPART
DetailsMike Jordan
jack; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa. framing on perimeter walls only. Verifiied all holdowns per plan. verified straps for beam to beam connections. Also inspected nailing on interior shear walls.
BLD-Framing/Rough-in3/27/20063/28/20063/28/2006PPART
DetailsMike Jordan
Jack -- roof nail inspection; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Roof insp. All missing hardware gas been installed. ok to cover roof. Contractor to supply RFI regarding placement of some straps.
BLD-Framing/Rough-in3/20/20063/21/20063/21/2006PFAIL
DetailsMike Jordan
Jack -- roof nail inspection; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Noted several areas were straps were not installed. Roof not ok to cover.
BLD-Framing/Rough-in3/14/20063/14/20063/14/2006PPART
DetailsMike Jordan
Jack -- shear wall; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Shear nailing on exterior walls only.
FIRE-Conference3/3/20063/6/20063/6/2006PDONE
DetailsTroy Cobbley
Jack; Phone #: ###-#### I went over manual pull station locations for the hood suppression system with Jack. They need to be located 10' to 20' away and between 4' and 5' AFF.
BLD-Footing1/11/20061/12/20061/12/2006PPART
DetailsMike Jordan
request early pm//jack; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa. All reinforcement in place, perimeter footings and interior column pads. Noted several areas with insufficient clearances, special inspector to verify prior to placement of concrete. wip
BLD-Conference1/9/20061/10/20061/10/2006ADONE
DetailsMike Jordan
###-#### - jack. Contractor questioned standing water in bottom of footings. Noted to contractor that water needs to be removed by pumping it out. Special inspector to verify bottom of footing condition.
(F) Reprint permit  12/2/2005  
Permit Ready to Issue  12/1/2005 DONE
Print Occupancy Form  12/1/2005 DONE
Telephone call  12/1/2005 DONE
talked to george at ###-#### that permit is ready & need r/p & achd
Issue PAID IN FULL permit  12/1/2005 DONE
Routing Off Site - STRUCTURAL11/21/2005 11/30/2005 PASS
Routing - PLAN CHECK11/30/2005 11/30/2005 PASS
Case Summary (BLD)  11/30/2005  
PLANS/APPL TAKEN TO FRONT DESK  11/30/2005 DONE
Plan assigned to (MLO)9/13/2005 11/30/2005 PASS
11/30/2005 09:24:55 MLO - activity updated through activity BLDA022 from case BLD05-02489.
Plan resubmittals received  11/21/2005  
Received (3) copies of sheet S2.1, S2.2, S3.1, S5.4, (2) response letters and (2) sets of revised structural calcs. Routed (1) set to structural and the remaining to Mike O.
Routing Off Site - STRUCTURAL11/8/2005 11/16/2005 FAIL
Phone call to Gordon Wright engineer with follow-up fax of corrections. MLO
Plan resubmittals requested  11/16/2005 DONE
additional structural comments.
Routing Off Site - STRUCTURAL10/19/2005 11/16/2005 FAIL
Routed to Stapley Engineering
Plan resubmittals received  11/8/2005  
Received (3) copies of sheet S1.0, S2.1, S2.2, S2.3, S3.1, S3.2, S4.1, S4.2, S5.1, S5.2, S5.3 and S5.4. Also received (2) sets of structural calcs. Routed to Mike P.
Telephone call  11/1/2005 DONE
Received phone call from engineer Mr. Gordon Wright who wishes to appeal having the building occupant load total used for building importance factor. WIshes to use a portion of the dining area to calculate occupant load to reduce factor and design. Mr. Gordon was informed this appeal must be completed prior to the permit being issued. MLO
Telephone call  11/1/2005 DONE
another phone call from structural engineer Gordon Wright. Building design will be corrected to comply with importance factor as required. Resubmittals are forth coming. MLO
Plan resubmittals received  10/31/2005  
Received (3) copies of sheet A-1, A-1.1, A-2, A-5, A-5.1, A-5.2, A-6, A-7.2, A-7.3, M-1, M-2, P-1, P-2, P-3, P-5, E-1, E-2, E-2A, E-2B, E-3, E-4, E-5, E-5.1 and C-2. Routed to Mike O.
1st review completed  10/20/2005 FAIL
failed structural
Routing - PLAN CHECK10/20/2005 10/20/2005 PEND
Routing - FIRE10/5/2005 10/20/2005 PASS
Plan resubmittals received  10/19/2005 DONE
Received 1 Letter of transmittal 2 response letters, 2 Structural Calcs, & 3 copys of sheets S1.0,S2.1,S2.2,S2.3,S3.1,S3.2,S4.1,S4.2,S5.1,S5.2,S5.3,S5.4 Taken to Mike O.
Routing Off Site - STRUCTURAL9/14/2005 10/5/2005 FAIL
corrections sent to architect
Plan resubmittals requested  10/5/2005 DONE
structural corrections
Routing - PLAN CHECK10/3/2005 10/5/2005 PEND
pending structural corrections
Routing - PLANNING9/23/2005 10/3/2005 PASS
Approved per DRH05-00233 and as noted on sheet A-4, which states that projecting sign requires separate permit and may need to be lowered per sign ordinance for projecting signs.
Routing - PLUMBING9/20/2005 9/23/2005 PASS
approved per plan and 2003 UPC and with local interceptor design condition.
Routing - PUBLIC WORKS9/15/2005 9/20/2005 PASS
Routing - Erosion and Sediment9/20/2005 9/20/2005 PASS
ESC plan approved with attached conditions.
Routing - PLANNING Land Div9/13/2005 9/15/2005 PASS
ROS_3967 signed by City Engineer on 8/8/97.
Plans ACCEPTED BY PLAN TECH  9/13/2005  
Plan routing begun/NEW & ADDTN  9/13/2005  
Application received  9/7/2005  
Recd Pcfee & Taken To Pln CK  9/7/2005  
Fee Review-notes9/7/20059/7/2005