Case Summary (BLD) | | | 4/14/2009 | | |
|
|
|
|
BLD-Aging Inspection | 5/30/2008 | 5/30/2008 | 5/30/2008 | | CANC |
Tom Arcoraci
|
|
|
|
DOC - Permit Expired | 5/30/2008 | 5/30/2008 | 5/30/2008 | A | PASS |
Tom Arcoraci
|
|
|
|
BLD-Aging Inspection | 2/13/2008 | 2/13/2008 | 2/13/2008 | | PASS |
Tom Arcoraci
|
|
|
|
BLD-Aging Inspection | 11/27/2007 | 11/27/2007 | 11/27/2007 | | CANC |
Tom Arcoraci
|
|
|
|
BLD-Aging Inspection | 9/26/2007 | 9/26/2007 | 9/26/2007 | | NR |
Tom Arcoraci
|
|
|
|
BLD-Aging Inspection | 7/24/2007 | 7/24/2007 | 7/24/2007 | | NR |
Tom Arcoraci
|
|
|
wip
|
BLD-Aging Inspection | 5/14/2007 | 5/14/2007 | 5/14/2007 | | PASS |
Tom Arcoraci
|
|
|
|
BLD-Framing/Rough-in | 3/13/2007 | 3/14/2007 | 3/14/2007 | P | PASS |
Tom Arcoraci
|
|
|
jd; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ok to rock ceiling in kit area, needs 2 layers 5/8 above ceililg on east side to complete vetical fire barrier
|
BLD-Aging Inspection | 12/5/2006 | 12/5/2006 | 12/5/2006 | | PASS |
Tom Arcoraci
|
|
|
|
BLD-Framing/Rough-in | 10/5/2006 | 10/5/2006 | 10/5/2006 | P | PART |
Tom Arcoraci
|
|
|
ok for cover
|
BLD-Framing/Rough-in | 9/20/2006 | 9/22/2006 | 9/22/2006 | P | PART |
Tom Arcoraci
|
|
|
chance - call prior to meet there; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley wip ok needs to cut truss s back to install 2 hr wall at east side
|
Override - Parcel Holds | 1/1/1900 | 1/1/1900 | 9/20/2006 | | |
|
|
|
|
BLD-Concrete | 8/21/2006 | 8/21/2006 | 8/21/2006 | P | PASS |
Tom Arcoraci
|
|
|
|
BLD-Footing | 8/18/2006 | 8/21/2006 | 8/21/2006 | A | NR |
Tom Arcoraci
|
|
|
chance - rebar; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
|
Override - Parcel Holds | 1/1/1900 | 1/1/1900 | 8/18/2006 | | |
|
|
|
|
BLD-Aging Inspection | 7/31/2006 | 7/31/2006 | 7/31/2006 | | NR |
Tom Arcoraci
|
|
|
exp
|
CHANGE STATUS TO (ISS) | | | 7/19/2006 | | DONE |
|
|
|
|
(F) Reprint permit | | | 7/19/2006 | | |
|
|
|
|
Plan assigned to (R_H) | 6/30/2006 | 6/30/2006 | 7/17/2006 | | PASS |
|
|
|
7/17/2006 09:10:15 RMH - activity updated through activity BLDA022 from case BLD05-03079.
|
Case Summary (BLD) | | | 7/17/2006 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/17/2006 | | DONE |
|
|
|
|
Override - Parcel Holds | | | 7/17/2006 | | |
|
|
|
|
Inspection Record Card- Bld | | | 7/17/2006 | | DONE |
|
|
|
|
Override - Parcel Holds | | | 7/17/2006 | | |
|
|
|
|
Permit Ready to Issue | | | 7/17/2006 | | |
|
|
|
|
Telephone call | | | 7/17/2006 | | DONE |
|
|
|
called ###-#### and left voicemessage for Rocky that permit is ready and fees
|
Plan Modification Accepted | | | 6/30/2006 | | |
|
|
|
Plan modification excepted for Bld05-03079 for the redo location of structural walls for roof suppport on sheets A0.1, A0.2, A1.1, A2.1, S1.1, routed to Ron Hill.
|
BLD-Aging Inspection | 4/19/2006 | 4/19/2006 | 4/19/2006 | | NR |
Tom Arcoraci
|
|
|
roof 7-17-06
|
Issue PAID IN FULL permit | | | 1/18/2006 | | |
|
|
|
|
Permit Ready to Issue | | | 12/30/2005 | | |
|
|
|
|
Inspection Record Card- Bld | | | 12/30/2005 | | DONE |
|
|
|
|
Telephone call | | | 12/30/2005 | | DONE |
|
|
|
called ###-#### and left message for Rocky w/Gary that permit is ready and fees
|
Plan assigned to (R_H) | 11/14/2005 | | 12/29/2005 | | PASS |
|
|
|
12/29/2005 10:41:20 RMH - activity updated through activity BLDA022 from case BLD05-03079.
|
Routing - PLAN CHECK | 11/14/2005 | | 12/29/2005 | | PASS |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 12/29/2005 | | DONE |
|
|
|
|
Plan resubmittals received | | | 12/23/2005 | | DONE |
|
|
|
Cover letter from architect and 3 copies of sheets A1.1 and A2.1 received and forwarded to Ron Hill.
|
Plan Reviewer's activity | | | 12/19/2005 | | FAIL |
|
|
|
Faxed requirements to the architect on 12/19/05
|
Plan resubmittals received | | | 12/16/2005 | | DONE |
|
|
|
Received 1 Response, & 3 copys of sheets A1.1,2.1 taken to Ron H.
|
Plans ACCEPTED BY PLAN TECH | | | 11/4/2005 | | |
|
|
|
|
Application received | | | 11/2/2005 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 11/2/2005 | | |
|
|
|
|
Fee Review-notes | 11/2/2005 | 11/2/2005 | | | |
|
|
|
|