Permit Information
Permit NumberBLD06-00056
StatusFinaled
Name KIEFFER DESIGN OFFICE
Site Address 1517 W MAIN ST
Project Name 
Customer Number 
ePlanReviewNo
Description
(KIEFFER DESIGN OFFICE) To remodel a 2,238 sq.ft. one story building from an assembly occupancy (A2) restaurant to use as a professional office occupancy (B) per plans, red-lined notes thereon, all attached plan review conditions and CZC05-00244. Work involves both exterior and interior changes. To perform selective demolition as indicated on plans; install new exterior roll-up door in new reinforced opening, new rear exit door with sidelight & hardware, infill with reinforced masonry window opening at alley end of building, new storefront windows and door assembly in existing openings and installation of exterior stucco finish; new interior walls to define office's, work area & conference room, and; upgrade of electrical, mechanical & plumbing to meet tenant needs and comply with current adopted codes and ordinances. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice BLD1/8/20071/8/20072/7/2007 DONE
Second Notice has not been responded to.
Fee Review-notes1/11/20061/11/20062/7/2007 DONE
Second Notice BLD12/27/200612/27/20061/8/2007 DONE
First Notice has not been responded to.
First Notice 10/25/200612/27/2006 DONE
Permanent occupancy  10/25/2006 DONE
Perm. Occ. Cerr. # 11264 issued 10-25-06 to the Kieffer Design Office.
Permanent Occupancy 8/16/20068/16/2006 DONE
Details
BLD-Final8/8/20068/9/20068/15/2006PPASS
DetailsDave Hannah
robin; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok for perm occ
FIRE-Final Inspection8/8/20068/9/20068/9/2006APASS
DetailsForrest France
Items on previous c/n have been completed, certification for the new extinguishers to be performed today.
BLD-Final8/4/20068/7/20068/7/2006ANR
DetailsTom Arcoraci
tom (or judy@###-####); Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
FIRE-Final Inspection8/4/20068/7/20068/7/2006AFAIL
DetailsForrest France
Provide two fire extinguishers per review notes mounted with the handle no higher than 48" AFF along a normal path of travel with a current certification tag, repair non-functional exit sign/emergency light at the main entry/exit, provide approved door hardware at the mens restroom and the back exit, provide doors and hardware at all locations indicated on plans for verification of code compliance, the threshold at the back exit exceeds min. height differential to the landing, roll up door at the exterior of the building above the back exit door is not allowed.
BLD-Framing/Rough-in6/21/20066/22/20066/22/2006APART
DetailsTony Young
tom - reinsp; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
rear door area/ colulm,, ok pending revision and letter of ok from engineer,, masonary to concrete,,
BLD-Framing/Rough-in6/21/20066/21/20066/21/2006PNR
DetailsTony Young
tom; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
BLD-Framing/Rough-in5/26/20065/26/20065/26/2006PPART
DetailsTony Young
TOM; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
interior walls ok to cover
BLD-Framing/Rough-in5/4/20065/5/20065/5/2006APART
DetailsTony Young
tom; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
interior walls W/OUT plumbing ok to cover
BLD-Framing/Rough-in4/12/20064/13/20064/13/2006APART
DetailsTony Young
Tom; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
walls w/ just elec. ok to cover,( non load bearing partion walls),, conf on a d a, ok to build half wall beside toilet for handrail
Issue PAID IN FULL permit  3/30/2006 DONE
Routing - PLAN CHECK3/10/2006 3/16/2006 PASS
To permit desk to issue.
PLANS/APPL TAKEN TO FRONT DESK  3/16/2006 PASS
Print Occupancy Form  3/16/2006 DONE
Telephone call  3/16/2006  
Left message with Patrick McKeegan Architects ###-#### to pick up permit and to provide G.C. and RCE# 3-16-06 eus
Permit Ready to Issue  3/16/2006  
Plan assigned to (DRS)1/26/2006 3/16/2006 PASS
3/16/2006 07:03:46 DRS - activity updated through activity BLDA022 from case BLD06-00056.
Routing - FIRE3/9/2006 3/10/2006 PASS
Attached review comments to plans. Faxed review comments to architect.
Routing - PLAN CHECK2/3/2006 3/9/2006 PEND
Received resubmittals from architect (3/2/06 & 3/8/06). No further resubmittals required. Re-routing to fire code analyst.
Plan resubmittals received  3/8/2006  
Received 1 cover memorandum letter, 2 copies of A3.0, 2 copies of A4.0 and taken to Dan S.
Plan Reviewer's activity  3/2/2006 DONE
Inserted architects resubmittal plans into original sets. Reviewing of resubmittals revealed that the lighting requirements for energy code compliance were designed improperly and exceeded allowed watts considerably for track lighting indicated. Also there is a question concerning the removal of masonry wall at the rear of the building for new 7' overhead door. this appears to leave approximately 14' of opening in masonry. No engineering was provided for this condition but the architects plans indicate a 1'-3" walls (pier) to be installed between the new overhead door and new man door with sidelight. I have called the engineer, Riley Mahafey and left a voice message asking him to call me back to discuss my concerns. I called Pat McKeegan concerning the energy code failure for the lighting. He will get with the owner and review what changes need to be made and resubmit.
Plan resubmittals requested  3/2/2006 DONE
Called Pat McKeegan to review energy code requirements for lighting, especially track lighting. Plan resubmittals show compliance by 10 watts but fixture count was off, wrong watts were used for some fixture's and method to determine track lighting requirements was not properly done. Energy code design is off considerably. Pat will review with Judy Keiffer and provide energy compliant drawings for this project.
Telephone call  3/2/2006 DONE
Called Riley Mahaffey, Lochsa Engineering, concerning the design requirements for the rear masonry wall having a large portion removed for new overhead door. Plans do not clearly indicate what is to be done. Left voice message for Riley to call me back.
Telephone call  3/2/2006 DONE
Called Pat McKeegan concerning plan resubmittals of 2/28/06 and noncompliance with energy code requirements for lighting for the new tenant. He will provide corrected drawings.
Plan resubmittals received  2/28/2006  
Received 1-2 page response letter 1 copy of United water flow info and 3 each of the following- T1.0, A1.0, A2.0, A2.1, A3.0, A4.0 and taken to Dan S.
Routing - FIRE2/3/2006 2/3/2006 FAIL
Faxed resubmittal items to architect. Comments attached to plans.
Routing - PLAN CHECK1/27/2006 2/3/2006 FAIL
Faxed and e-mailed copy of items needing to be addressed by the architect before further plan review can be done. Routing to fire code analyst for review.
1st review completed  2/3/2006 FAIL
Failed Plan Check and Fire.
Plan resubmittals received  1/31/2006 DONE
Received 1 letter taken to Dan S.
Routing - PLANNING1/31/2006 1/31/2006 PASS
Received a letter from the applicant indicating the canopy will not be constructed at this time.
Routing - PUBLIC WORKS1/26/2006 1/27/2006 PASS
Routing - PLANNING1/27/2006 1/27/2006 FAIL
Cody Riddle CZC05-00244

Applicant failed to provide the required lic. agreement w/ ACHD for the awning overhanging the ROW.
Plans ACCEPTED BY PLAN TECH  1/13/2006  
Application received  1/11/2006  
Recd Pcfee & Taken To Pln CK  1/11/2006 DONE