Permit Information
Permit NumberBLD06-00057
StatusExpired
Name BENCHMARK CONSTRUCTION INC
Site Address 9543 W EMERALD ST
Project NameEMERALD BLDG
Customer Number 
ePlanReviewNo
Description
(EMERALD BUILDING formerly Sailfish Place) To remodel an existing 2 story 22,054 sq. ft. office/retail/warehouse building per approved plans and CZC05-00260. The remodel will create several suites on both floors for future leasing. The building is currently mostly all vacant except one existing tenant in a Suite on the north end of the building. No occupancy allowed under this permit in any of the vacant suites. Separate permits will be required to be obtained for tenants to occupy the suites. Work will include some interior demolition work, three new exterior openings in the south exterior wall, a new exterior steel canopy, some new skylight installations, a new elevator installation, a one-hour rated elevator equipment room, demolishing and reconstructing two new interior stairways, some new structural floor framing work, two new reinforced concrete footings, some new interior walls, some new interior doors and windows, interior finish, some suspended ceiling and gyp. board ceiling work, two new accessible restrooms on the second floor, fire sprinkler and alarm work, mechanical work, plumbing work, and electrical work. Special Inspection required for masonry work at new CMU elevator shaft walls, for concrete and reinforcement, for structural steel work/welding, adhesive/epoxy anchors, and expansion anchors per engineer. This is a Scope of Work Permit. A Letter of Completion is to be issued when done. Nonseparated Uses per IBC Section 302.3.1. NOTE: This building is fully fire sprinklered for area increase. JCB
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection9/28/20109/28/20109/30/2010 DONE
DetailsMike Jordan
DOC - Permit Expired9/30/20109/30/20109/30/2010APASS
DetailsMike Jordan
Permit is expired. No work or required inspections have been conducted. Will have to submit new plans and get new permit for ant further work.
BLD-Aging Inspection7/26/20107/26/20108/3/2010 PEND
DetailsMike Jordan
Case Summary (BLD)  6/17/2010  
BLD-Aging Inspection4/28/20104/28/20104/28/2010 PEND
DetailsMike Jordan
Case Summary (BLD)  4/23/2010  
Meeting  4/23/2010 DONE
Met with owner's representative. Proposal to construct an elevator addition outside of the current building envelope. Told him that a new permit is required. Sent him to talk to Planning about Design Review. Asked him to have the Architect provide "as-builts" so that we will know what work was done under this permit so that it can be expired. CJW
Case Summary (BLD)  3/25/2010  
BLD-Other6/30/20087/1/20087/1/2008PPASS
DetailsMike Jordan
Scheduled by a contractor via Hello! on 6/30/2008 at 3:27:41 PM. Contact: ###-####. ceiling grid ok. All issues resolved.
BLD-Other6/24/20086/25/20086/25/2008AFAIL
DetailsMike Jordan
Scheduled by a contractor via Hello! on 6/24/2008 at 2:02:43 PM. Contact: ###-####. Fire sprinler ri insp. failed. Also needs to provide approved plans, provide additional wires for diffusers and return air grills and complete west wall. c/n posted.
BLD-Other4/18/20084/18/20084/18/2008PPASS
DetailsJim Sly
george Note: grid Phone #: ###-####
BLD-Conference4/9/20084/9/20084/9/2008PPASS
DetailsMike Jordan
Spoke to George with Benchmark const. regarding this job. No new work is planned but maybee in near future. Noted to George that permit is about to expire. If no new work is going to take place in next 90 days, they may have to have scope of work modified to reflect what is completed at this time and resubmit new plans when remaining work can take place. Contractor siad he would call in a ceiling grid insp.
BLD-Other8/17/20078/17/20078/17/2007PCANC
DetailsMike Jordan
scott Note: ceiling grid Phone #: ###-####2nd floor corridor.
BLD-Other8/8/20078/9/20078/9/2007ANR
DetailsMike Jordan
scott - ceiling grid Phone #: ###-####. Approved plan calls for hardlid, contractor has switched to grid ceiling. Needs to resubmit refected ceiling plan for approval.
BLD-Framing/Rough-in6/26/20076/27/20076/27/2007APART
DetailsMike Jordan
scott Phone #: ###-####. Phase 1. Inspected wood framed walls at 2nd floor corrridors, and privously built steel stud walls at 1st. floor. Needs to have elec. ok 1st. floor before cover.
BLD-Aging Inspection4/9/20074/9/20074/13/2007 CANC
DetailsMike Jordan
Issue PAID IN FULL permit  1/5/2007 DONE
Ready Permit EXTENDED  10/12/2006  
per jenifer g. will extend permit until january 8th 2007. see scanned document.
Telephone call  9/25/2006 DONE
patrick mckeegan came in to pay for permit and told him we needed the g.c. 1st. he said it was out to bid. i talked to him last friday and did not have a change to talk to rita..regarding permit has expired--he wrote a letter to jenifer g. for an extension...definitely wants permit
Telephone call  9/20/2006 DONE
left mess for pat mckeegan at ###-#### that permit is ready
Permit Ready to Issue  9/5/2006 DONE
Telephone call  9/5/2006 DONE
left mess for patrick at ###-#### that permit is ready
Routing - PLAN CHECK8/29/2006 8/31/2006 PASS
Plans and permit approved and taken to front desk.
PLANS/APPL TAKEN TO FRONT DESK  8/31/2006 PASS
Print Pending Permit.LaserJet4  8/31/2006  
Case Summary (BLD)  8/31/2006  
Inspection Record Card- Bld  8/31/2006 DONE
Plan assigned to (JCB)1/26/2006 8/31/2006 PASS
8/31/2006 12:58:35 JCB - activity updated through activity BLDA022 from case BLD06-00057.
Routing - Erosion and Sediment8/29/2006 8/29/2006 PASS
ESC waiver request approved with attached conditions.
Routing - PLAN CHECK8/15/2006 8/29/2006 FAIL
Still need architect to come in and sign sheets A4.1 and A4.2 and also the Lighting Compliance. Plans to route to Erosion/Sediment Control for review.
Plan resubmittals received  8/25/2006  
Received transmittal sheet, erosion & sediment control applicaiton, revised Certificate of Value, 5pg. Project Start Up for Special Inspections, 2 sets of structural calculations, 2 copies of the following pages: S1.1, S1.2, S2.1, A4.1 (not signed), A4.2 (not signed); taken to Jason Blais
Routing - PLANNING8/14/2006 8/15/2006 PASS
Sarah. Approved per CZC05-00260
Routing - PLAN CHECK7/10/2006 8/14/2006 FAIL
Still have not received requested items. Plans to route to Sarah in Planning.
1st review completed  7/10/2006 FAIL
Failed Plan Check.
Routing - FIRE7/6/2006 7/10/2006 PASS
Attached review comments to plans.
Routing - PLAN CHECK3/1/2006 7/6/2006 FAIL
Called architect. Some issues still needing to be addressed were discussed. Architect stated he will fax additional information over in the next few days. Plans to route to Fire Dept. for review.
Telephone call  7/5/2006 DONE
Talked with Pat McKeegan concerning some issues still needing to be addressed. He acknowledged and will fax over some additional information in the next few days.
Telephone call  7/3/2006 DONE
Called and left a message for Pat McKeegan to discuss the project.
Plan resubmittals received  6/8/2006 DONE
Received 2 structural calcs,& 3 copys of sheets g0.1,a1.1,a2.1,a2.2,a3.1,a3.2,a3.3,a3.4,a3.5,a4.1,a4.2a4.3,a4.4,a4.5,a5.1,a6.1,a6.2,a8.1,s1.1,s1.2,s2.1 taken to Jason B.
Routing - FIRE3/1/2006 3/1/2006 FAIL
No fire review done. Talked with Scott A. Does not want to review the plans if I have not reviewed the plans. Plans submitted were not reviewable. Numerous issues to address. Met with architect and he will address and provide more complete plans.
Routing - Erosion and Sediment3/1/2006 3/1/2006 FAIL
Talked with Steve Webb and need ESC application to be submitted.
Meeting  3/1/2006 DONE
Plans are incomplete and not reviewable. (Missing a lot of structural calculations/designs/details, accessible route/elevator required to second floor, fire rated walls/doors shown for unknown reason, exiting issues, etc...) Met with architect to go over several issues. A full plan review has not been conducted. A full plan review will need to be done when resubmittal plans are provided. Architect stated he would address and resubmit more complete plans.
1st review completed  3/1/2006 FAIL
Failed planning, plan review, erosion/sediment control, and fire.
Routing - PLAN CHECK1/31/2006 2/28/2006 FAIL
Plans are incomplete and not reviewable. (Missing a lot of structural calculations/designs/details, accessible route/elevator required to second floor, fire rated walls/doors shown for unknown reason, exiting issues, etc...) Met with architect to go over several issues. A full plan review has not been conducted. A full plan review will need to be done when resubmittal plans are provided. Architect stated he would address and resubmit more complete plans.
Routing - PLANNING1/27/2006 1/31/2006 FAIL
Does not comply with conditions of CZC05-00260.
Routing - PUBLIC WORKS1/26/2006 1/27/2006 PASS
Plans ACCEPTED BY PLAN TECH  1/13/2006  
Application received  1/11/2006  
Recd Pcfee & Taken To Pln CK  1/11/2006 DONE
Fee Review-notes1/11/20061/11/2006   
Plan resubmittals received    8
Received 1 cover transmittal and 1 copy of sheet A4.4 and taken to George Slane for Mike Jordan also called Mike Jordan and told him that the plans are in George's office///8/14/07 @ 4:07pm BAS