Permit Information
Permit NumberBLD06-00173
StatusFinaled
Name BURGUNDY HOMES
Site Address 620 E ORION DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Rick Patterson contractor registration number is RCE-0564. To construct a four bedroom, two and half bathroom 3368 sq. ft. two story single family dwelling (2439 sq. ft. first floor/929 sq. ft. second floor) with a attached 1024 sq. ft. three car garage, a 214 sq. ft. covered back porch and a 124 sq. ft. covered front porch. Per approved plans, engineering and requirement list. This lot is within a hillside area and is subject to the hillside ordinances. A class "A" roof system and defensible area will be maintained. This house shall be fitted with an NFPA 13D system, modified to include a single row of dry sidewalls sprinklers along all walls common to attached garage and the living space. The system shall also be equipped with an alarm initiating device commonly referred to as a flow switch, and an outside alarm indicating device. A Fire Sprinkler Permit is required prior to beginning any fire sprinkler work. (SAM) 5/31/06 FIRE SPRINKLERS ARE NOT REQUIRED ON THIS LOT. SEE ACTIVITIES. (SAM)
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/7/200612/7/200612/7/2006PPASS
DetailsTom Arcoraci
jason - call for access - please call 1/2 prior to inspection ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith co issued
DOC - Permit Finaled12/7/200612/7/200612/7/2006PPASS
DetailsTom Arcoraci
BLD-Grading Inspection12/7/200612/7/200612/7/2006 DONE
Received Engineers approval of site grading. Final grading and drainage approved.
BLD-Framing/Rough-in6/2/20066/5/20066/5/2006APART
DetailsTony Young
christian - call prior to insp; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
wip on int. shear,, ok
BLD-Framing/Rough-in6/2/20066/2/20066/2/2006PNR
DetailsTony Young
bill; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
BLD-Conference5/31/20065/31/20065/31/2006PPASS
DetailsTony Young
verify that sprinklers are not reqd
ok now,, see notes
BLD-Energy code compliance5/31/20065/31/20065/31/2006PPASS
DetailsTony Young
verify that sprinklers are not reqd
ok ,,, see notes,, ok to sheet rock,, need interior shear inspection later,, sheet rock#4
Meeting  5/31/2006 DONE
Walk-in meeting with Doug Jayo regarding sprinkler requirement for this house. Identified the location of this house and clarified email memo from Dave Miller based on plat notes for Subdivision #4 and concluded that only the houses on Orion Court require sprinklers. This house is Orion Drive which is directly across Pleasant Hill from Orion Court so it does NOT require fire sprinklers. Advised Tony Young, Building inspector, to NOT require sprinklers.
BLD-Energy code compliance5/26/20065/30/20065/30/2006AFAIL
DetailsTony Young
bill cell - call prior to insp; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
THIS PERMIT REQUIRES SPRINKLERS PER THE PLANS,, NOT NOT COVER
BLD-Framing/Rough-in5/24/20065/25/20065/25/2006APART
DetailsTony Young
bill - call prior to insp for access; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
exterior shear ok to cover
BLD-Framing/Rough-in5/24/20065/25/20065/25/2006APART
DetailsTony Young
bob - call prior to insp for access; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
ok to insulate,, need approved plans for energy,, need f/blocks,, straps,, truss braces,, etc
Plan Reviewer's activity  4/19/2006 DONE
08:00 I called and talked to Christian about this project. I let him know that there is a NON-BUILD for this phase and he needs to stop construction.

NON-BUILD HAS BEEN TAKEN CARE OF.`
BLD-Framing/Rough-in4/14/20064/17/20064/17/2006APART
DetailsTony Young
Rick -- shear insp; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
lower level exterior,, base layer ok,,, ok to add next exterior non structural layer,, still need upper levels
BLD-Foundation3/23/20063/24/20063/24/2006APART
DetailsTony Young
James -- pouring concrete at 10:30 AM; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
miss layout on some ftgs,,, re-doing,, ok ,, wip
BLD-Footing3/21/20063/22/20063/22/2006APART
DetailsTony Young
Phone #: ###-####
BLD-Footing3/20/20063/21/20063/21/2006PNR
DetailsTony Young
James; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
PubWorks Subgrade Approval3/17/20063/17/20063/17/2006 DONE
fFOTING SUBGRADE APPROVED BY THE GEOTECHNICAL ENGINEER
Issue PAID IN FULL permit  3/8/2006 DONE
Plan assigned to (SAM)1/25/20062/7/20062/9/2006 PASS
2/9/2006 14:24:03 SAM - activity updated through activity BLDA022 from case BLD06-00173.
Routing - PLAN CHECK1/30/2006 2/9/2006 PASS
Case Summary (BLD)  2/9/2006  
PLANS/APPL TAKEN TO FRONT DESK  2/9/2006 DONE
Inspection Record Card- Bld  2/9/2006 DONE
Permit Ready to Issue  2/9/2006 DONE
Telephone call  2/9/2006  
Left message to pick up permit ###-#### eus 2-9-06
Routing - FIRE1/30/2006 1/30/2006 PASS
This house requires a modified NFPA 13D sprinkler system, modifications to include sprinklers in all closets, bathrooms and a single row of dry sidewall sprinklers installed in attached garages along the common wall(s) separating the garage(s) from living (heated) spaces. (Somerset Ridge sub, Orion Ct.)
5/31/2006-REVISED-see 5/31 meeting notes below. Due to its location on Pleasant Hill and Orion Drive, the requirement for sprinklers will NOT apply.
Routing - Erosion and Sediment1/27/2006 1/27/2006 PASS
ESC plan approved with attached conditions.
Routing - PUBLIC WORKS1/26/2006 1/27/2006 PASS
Routing - PLANNING1/27/2006 1/27/2006 PASS
24" maximum overhang in setbacks
Driveway 33' wide maximum in setbacks
spa 1' in height or less in rear setback
Application received  1/25/2006  
Routing - PUBLIC WORKS GRADING1/25/2006 1/25/2006 PASS
Approved as Category 3

Geotechnical report indicates expansive clay where there was not supposed to be any. Need to have report reviewed by Developer's geotech.1/25/06