Fee Review-notes | 3/22/2006 | 3/22/2006 | 3/3/2008 | | DONE |
Cathy Brown
|
|
|
|
Second Notice BLD | 2/6/2008 | 2/6/2008 | 2/11/2008 | | DONE |
Cathy Brown
|
|
|
First Notice has not been responded to.
|
First Notice | | 1/15/2008 | 2/6/2008 | | DONE |
|
|
|
|
Permanent Occupancy | | | 1/15/2008 | | DONE |
|
|
|
|
BLD-Aging Inspection | 12/18/2007 | 12/18/2007 | 12/18/2007 | | PASS |
Tom Arcoraci
|
|
|
|
BLD-Final | 10/16/2007 | 10/16/2007 | 10/16/2007 | P | PASS |
Tom Arcoraci
|
|
|
mitch Phone #: ###-####
|
Override - Parcel Holds | 10/16/2007 | 1/1/1900 | 10/16/2007 | | |
|
|
|
fire code
|
Code Occupancy Approval | 10/11/2007 | 10/11/2007 | 10/11/2007 | P | PASS |
Dena Gambrel
|
|
|
10-11-07 Passed.
|
FIRE-Final Inspection | 10/9/2007 | 10/9/2007 | 10/9/2007 | P | PASS |
Troy Cobbley
|
|
|
life safety passed
|
Override - Parcel Holds | 10/9/2007 | 1/1/1900 | 10/9/2007 | | |
|
|
|
they are doing fire inspection
|
FIRE-Final Inspection | 8/30/2007 | 8/31/2007 | 8/31/2007 | A | PART |
Troy Cobbley
|
|
|
This inspection was for 5237 only. It is ok with me to occupy. No signature was given since the scope of work was for four condo's.
|
BLD-Final | 8/30/2007 | 8/31/2007 | 8/31/2007 | P | PASS |
Tom Arcoraci
|
|
|
Daniel; Phone #: ###-#### Internet Inspection Request from: Hattie James
|
BLD-Energy code compliance | 8/6/2007 | 8/7/2007 | 8/7/2007 | P | PASS |
Tom Arcoraci
|
|
|
mitch. Phone #: ###-#### ok pending mech
|
BLD-Energy code compliance | 8/3/2007 | 8/6/2007 | 8/6/2007 | A | PART |
Tom Arcoraci
|
|
|
Mitch; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
|
BLD-Footing | 6/12/2007 | 6/13/2007 | 6/13/2007 | P | PASS |
Jim Sly
|
|
|
Mitch ###-####
|
Issue PAID IN FULL permit | | | 6/12/2007 | | DONE |
|
|
|
|
Telephone call | | | 5/1/2007 | | |
|
|
|
mitch with granite const left mess stating he still wants plans- has been picking them up randomly
|
Print Occupancy Form | | | 7/12/2006 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 7/12/2006 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/10/2006 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 7/10/2006 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 6/29/2006 | | 7/10/2006 | | PASS |
|
|
|
|
Plan assigned to (M_P) | 3/23/2006 | | 7/10/2006 | | PASS |
|
|
|
7/10/2006 16:17:42 M_P - activity updated through activity BLDA022 from case BLD06-00710.
|
Plan resubmittals received | | | 6/30/2006 | | |
|
|
|
Received 2 copies of the following pages-- Cover transmittal, Plan review comments letter, A-2, A-4 and taken to Mike Phillips
|
Routing - PLAN CHECK | 6/15/2006 | | 6/29/2006 | | FAIL |
|
|
|
Second review failed, sent correction report to the architect requesting additional informaiton be submitted for further review prior to issuing permit.
|
Routing - FIRE | 6/12/2006 | | 6/15/2006 | | PASS |
|
|
|
Resubmitted United Water fire flow information dated 6/7/06. Attached review comments to the plans.
|
Routing - PLAN CHECK | 5/17/2006 | | 6/12/2006 | | |
|
|
|
Routing to the fire department.
|
Plan resubmittals received | | | 6/8/2006 | | DONE |
|
|
|
received 1 transmittal, & 1 Fire flow sheet taken to Mike P.
|
Plan resubmittals received | | | 6/5/2006 | | |
|
|
|
Received 2 of each of the following forms--cover transmittal letter,PLan review report, valley engineering response letter, A-S, A-L, A-1, A-1.1, A-2, A-3, A-4, EN, S-1, SA-2, SA-3, SA-4 and taken to Mike Phillips
|
Routing - PUBLIC WORKS | 5/16/2006 | | 5/17/2006 | | PASS |
|
|
|
|
Routing - PLAN CHECK | 5/10/2006 | | 5/16/2006 | | |
|
|
|
Routing to P.W.
|
Routing - FIRE | 5/9/2006 | | 5/10/2006 | | FAIL |
|
|
|
Faxed resubmittal item to architect. Attached review comments to plans.
|
1st review completed | | | 5/8/2006 | | FAIL |
|
|
|
Failed Plan Check & Fire.
|
Telephone call | | | 5/8/2006 | | PEND |
|
|
|
Spoke with Architect and requested submittal of fire flow information from United Water. Awaiting submittal of required documentation.
|
Routing - FIRE | 5/5/2006 | | 5/8/2006 | | FAIL |
|
|
|
Spoke with Architect regarding required submittal of United Water Fire Flow documentation. Awaiting submittal of Water Fire Flow documentation.
|
Routing - PLAN CHECK | 4/6/2006 | | 5/5/2006 | | FAIL |
|
|
|
Plan review completed, sent correction report to the architect requesting additional information be submitted for further review prior to issuing permit.
|
Routing - PLANNING | 4/6/2006 | | 4/6/2006 | | PASS |
|
|
|
CUP03-00078 per mod Angela W.
|
Routing - PLANNING | 4/3/2006 | | 4/5/2006 | | PASS |
|
|
|
DRH06-00019 Cody R. CUP03-00078
Meets DR requirements per H. Simmons/S. Schafer
|
Routing - PLUMBING | 3/31/2006 | | 4/3/2006 | | PASS |
|
|
|
|
Routing - Erosion and Sediment | 4/3/2006 | | 4/3/2006 | | PASS |
|
|
|
4/3/06 Refer to ESC06-00406 as master ESC plan for entire project.adh.
|
Routing - Erosion and Sediment | 3/30/2006 | | 3/31/2006 | | FAIL |
|
|
|
No esc narrative routed from p. works.
|
Routing - PUBLIC WORKS | 3/24/2006 | | 3/30/2006 | | FAIL |
|
|
|
WAITING FOR TRASH COMMENTS FOR FINAL SIGN OFF BY TRASH
|
Routing - PLANNING Land Div | 3/23/2006 | | 3/24/2006 | | PASS |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 3/23/2006 | | |
|
|
|
|
Plan routing begun/NEW & ADDTN | | | 3/23/2006 | | |
|
|
|
|
(F) Reprint permit | | | 3/23/2006 | | DONE |
|
|
|
|
Application received | | | 3/22/2006 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 3/22/2006 | | |
|
|
|
|