(F) Reprint permit | | | 5/21/2007 | | |
|
|
|
|
(F) Reprint permit | | | 5/18/2007 | | |
|
|
|
|
BLD-Final | 2/28/2007 | 3/1/2007 | 3/1/2007 | A | PASS |
Mike Jordan
|
|
|
adem; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
|
DOC - Permit Finaled | 3/1/2007 | 3/1/2007 | 3/1/2007 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Energy code compliance | 10/12/2006 | 10/12/2006 | 10/12/2006 | P | DONE |
Mike Jordan
|
|
|
aden; Phone #: ###-#### Internet Inspection Request from: Patricia Smith. This insp. was done yesterday.
|
BLD-Energy code compliance | 10/11/2006 | 10/11/2006 | 10/11/2006 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung
|
BLD-Framing/Rough-in | 10/9/2006 | 10/10/2006 | 10/10/2006 | A | NR |
Mike Jordan
|
|
|
adam; Phone #: ###-#### Internet Inspection Request from: Patricia Sm. wip.
|
BLD-Framing/Rough-in | 10/5/2006 | 10/5/2006 | 10/5/2006 | P | PASS |
Mike Jordan
|
|
|
Adam; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt. All framing issues have been resolv ed. ok to insul.
|
BLD-Framing/Rough-in | 10/2/2006 | 10/2/2006 | 10/2/2006 | P | FAIL |
Mike Jordan
|
|
|
adam; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Needs to complete repair of D4 truss as per truss engineering. Riser on stairs vary greater than the 3/8 inch allowed. Egress windows upstairs exceed the 42 inch max height. c/n posted. All other framing issues have been resolved. ok to insul.
|
BLD-Framing/Rough-in | 9/15/2006 | 9/15/2006 | 9/15/2006 | P | DONE |
Mike Jordan
|
|
|
adam; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. THIS WAS A CONFERANCE. Met with contractor on site and went over c/n notice. Some additional corrections were added. Needs to repair stair way, walking surface was sloped to much, Needs to remove window from bathroom to garage. Add blocking and studs to rimjoist at 3ply girder truss. add strap at top plate in garage and remove closet from mech. room and get engineered fix for D4 truss. Add trimmers at 3ply truss in garage.
|
BLD-Framing/Rough-in | 9/13/2006 | 9/13/2006 | 9/13/2006 | P | FAIL |
Mike Jordan
|
|
|
Adam; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt. Complete lateral bracing. Tbe required at 3ply girder truss in garage. Fireblock mech. chase and all furouts. c/n posted. do not insul.
|
BLD-Framing/Rough-in | 9/12/2006 | 9/13/2006 | 9/13/2006 | A | NR |
Mike Jordan
|
|
|
adam; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Needs to provide an approved set of plans for framing insp. c/n posted.
|
Plan assigned to (SRZ) | 5/4/2006 | 5/4/2006 | 6/5/2006 | | PASS |
|
|
|
6/5/2006 09:00:21 SRZ - activity updated through activity BLDA022 from case BLD06-01036.
|
Routing - PLAN CHECK | 4/13/2006 | | 6/5/2006 | | PASS |
|
|
|
|
Case Summary (BLD) | | | 6/5/2006 | | |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 6/5/2006 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 6/5/2006 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 6/5/2006 | | DONE |
|
|
|
|
Plan resubmittals received | | | 6/2/2006 | | PASS |
|
|
|
Recieved complete plans. (SRZ)
|
Plan Reviewer's activity | | | 5/31/2006 | | |
|
|
|
Ned the builder (Idaho Best Co.) called and said he was fired and wants his name off the permit. I told him the Home owner will need to call me and get his name transfered to the permit. (SRZ)
|
Plan Reviewer's activity | | | 5/31/2006 | | |
|
|
|
Owner Adem Mesinovic transfered permit to his name. (SRZ)
|
BLD-Footing | 5/17/2006 | 5/18/2006 | 5/18/2006 | A | PART |
Mike Jordan
|
|
|
RICK ###-####. early start,
|
Telephone call | | | 5/9/2006 | | |
|
|
|
Talked with Designers Engineer. Let him know what I have requested from builder to get permit completed. (SRZ)
|
Telephone call | | | 5/9/2006 | | |
|
|
|
Spoke with Designers lumber provider. NO HELP..with what's needed to complete Plan review. I called builder and requested completed structure on plans. (SRZ)
|
Plan assigned to (SAM) | 4/12/2006 | 4/12/2006 | 5/4/2006 | | DONE |
|
|
|
|
Plan resubmittals requested | | | 5/4/2006 | | PEND |
|
|
|
Incomplete structural plans. Need Roof framing plan and floor framing beam calculations to complete plan review. (SRZ)
|
Early Start Permit | | | 5/1/2006 | | DONE |
|
|
|
|
Telephone call | | | 5/1/2006 | | DONE |
|
|
|
Spoke with Ned and told him that early start is ready he can come sign for it///5/1/06 @8:30 BAS
|
Routing - PLANNING | 4/12/2006 | | 4/13/2006 | | PASS |
|
|
|
Using R-1C setbacks
|
Routing - PUBLIC WORKS | 4/13/2006 | | 4/13/2006 | | PASS |
|
|
|
|
Application received | | | 4/12/2006 | | |
|
|
|
|