Third Notice BLD | 9/22/2008 | 9/22/2008 | 2/26/2009 | | DONE |
Patricia Smith
|
|
|
Second Notice has not been responded to.
|
Second Notice BLD | 8/11/2008 | 8/11/2008 | 9/22/2008 | | DONE |
Cathy Brown
|
|
|
First Notice has not been responded to.
|
First Notice | | 6/27/2008 | 8/11/2008 | | DONE |
|
|
|
|
Permanent Occupancy UNPAID FEE | | | 6/27/2008 | | DONE |
Cathy Weisshaupt
|
|
|
|
BLD-Final | 4/21/2008 | 4/21/2008 | 4/21/2008 | P | PASS |
Dave Hannah
|
|
|
joe Phone #: ###-#### ok for perm occ
|
Temporary occupancy | | | 5/14/2007 | | DONE |
|
|
|
Temp. Occ. Cert. # 5586 issued 5-14-07 to Chopsticks.
|
BLD-Final | 5/9/2007 | 5/10/2007 | 5/10/2007 | A | PART |
Dave Hannah
|
|
|
joe ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok for temp occ
|
BLD-Final | 5/4/2007 | 5/8/2007 | 5/9/2007 | P | FAIL |
Dave Hannah
|
|
|
joe; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles needs other trades finaled
|
FIRE-Final Inspection | 5/4/2007 | 5/8/2007 | 5/8/2007 | A | PASS |
Forrest France
|
|
|
Corrections are complete, fire life safety inspection passed.
|
Print Occupancy Form | | | 3/30/2007 | | DONE |
|
|
|
|
BLD-Framing/Rough-in | 10/6/2006 | 10/9/2006 | 10/9/2006 | A | PART |
Dave Hannah
|
|
|
Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok to cover walls after gas piping test
|
BLD-Conference | 9/25/2006 | 9/25/2006 | 9/27/2006 | P | PEND |
Dixie Fellows
|
|
|
per dixie..spoke with owner (johnny) and suggested he go back to his engineer ? and have him revise the mechanical drawings on the type 1 hoods and grease ducts, terminations, make-up air, clearances, etc to comply with the imc section on commercial kitchen equipment. then once that is done and he has hired a licensed mechanical contractor they will schedule a conference and we will all meet, review the plans and discuss the job..i also told him the hoods he had purchased for this job couldn't be installed as they have no listings per the imc.
|
Plan assigned to (JCB) | 5/12/2006 | | 8/3/2006 | | PASS |
|
|
|
8/3/2006 08:40:43 JCB - activity updated through activity BLDA022 from case BLD06-01358.
|
Routing - PLAN CHECK | 7/31/2006 | | 8/3/2006 | | PASS |
|
|
|
Permit and plans approved and taken to front desk.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/3/2006 | | PASS |
|
|
|
|
Print Pending Permit.LaserJet4 | | | 8/3/2006 | | |
|
|
|
|
Case Summary (BLD) | | | 8/3/2006 | | |
|
|
|
|
Print Occupancy Form | | | 8/3/2006 | | DONE |
|
|
|
|
Telephone call | | | 8/3/2006 | | DONE |
|
|
|
tlk to johnny guan ###-#### that permit and fees are ready to be picked up but needs RCE and GC
|
Permit Ready to Issue | | | 8/3/2006 | | DONE |
|
|
|
|
Issue PAID IN FULL permit | | | 8/3/2006 | | DONE |
|
|
|
|
Routing - FIRE | 7/28/2006 | | 7/31/2006 | | PASS |
|
|
|
Attached updated review comments to plans.
|
Routing - PLUMBING | 7/24/2006 | | 7/28/2006 | | PASS |
|
|
|
Then route to Fire. vent floor sinks at the front counter, add hand sink at the soda mechine, relocate hand sink in the service area per redline on page A-1. toilets and urinals may not drain to the grease interceptor. additional cross connection protection may be required.
|
Routing - PUBLIC WORKS | 7/24/2006 | | 7/24/2006 | | PASS |
|
|
|
Then route to Plumbing.
|
Routing - PLAN CHECK | 6/2/2006 | | 7/24/2006 | | PEND |
|
|
|
Plans to route to Public Works, Plumbing, and Fire Dept. for review of resubmittals. When approved by these divisions, the permit can then be issued.
|
Plan resubmittals received | | | 7/19/2006 | | |
|
|
|
received "3" booklets 11 pages each from barbara a beier architect & "3" sets of plans including 3 sheets each of A-O , A-1, E-2, P-1, P-2, M-2-& --plans taken to jason blais
|
1st review completed | | | 6/2/2006 | | FAIL |
|
|
|
Failed Plan Check, Fire, Public Works, and Plumbing.
|
Routing - FIRE | 5/31/2006 | | 6/2/2006 | | FAIL |
|
|
|
Faxed resubmittal item to Barbara Beier. Attached review comments to plans.
|
Plan resubmittals requested | | | 5/31/2006 | | DONE |
|
|
|
Plan resubmittals and written response required for further review.
|
Routing - PLAN CHECK | 5/18/2006 | | 5/31/2006 | | FAIL |
|
|
|
Plan review e-mailed and faxed to architect. Plan resubmittals and written response required for further review. Plans to route to Fire Dept. for review.
|
Routing - PLUMBING | 5/16/2006 | | 5/18/2006 | | FAIL |
|
|
|
satisfy public works pretreatment requirements and resubmit.
|
Routing - PLANNING | 5/15/2006 | | 5/16/2006 | | PASS |
|
|
|
Cody Riddle
|
Routing - PUBLIC WORKS | 5/12/2006 | | 5/15/2006 | | FAIL |
|
|
|
All kitchen grey water drainage needs to be plumbed to grease interceptor. Sources include mopsink, pre-wash station, dishwater, floor sinks and hand sinks located in the kitchen as well as the triple sink.
Contact Mike Hunter at ###-####
|
Plans ACCEPTED BY PLAN TECH | | | 5/11/2006 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 5/11/2006 | | DONE |
|
|
|
|
Application received | | | 5/10/2006 | | |
|
|
|
|