BLD-Final | 12/7/2006 | 12/7/2006 | 12/7/2006 | P | PASS |
Mike Jordan
|
|
|
Calvin; Phone #: ###-####, call 1st for access Internet Inspection Request from: Cathy Weisshaupt
|
DOC - Permit Finaled | 12/7/2006 | 12/7/2006 | 12/7/2006 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Energy code compliance | 9/6/2006 | 9/7/2006 | 9/7/2006 | A | PASS |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 9/6/2006 at 6:10:33 PM. Contact: ###-####. F & E OK
Overl......S M.G. E Targee
|
BLD-Framing/Rough-in | 9/5/2006 | 9/5/2006 | 9/5/2006 | P | FAIL |
Mike Jordan
|
|
|
calvin; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley. Complete airseal package prior to insul. Provide strap at 2ply ml beam in garage. Provide header upstairs over opening at truss bearing. 6x12 post required or eng equiv. at 4ply girder truss. Needs to fireblock all furouts and drop ceilings by fireplace. ok to insul. c/n posted.
|
BLD-Footing | 7/25/2006 | 7/26/2006 | 7/26/2006 | A | PART |
Mike Jordan
|
|
|
ben; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. wip.
|
Issue PAID IN FULL permit | | | 7/21/2006 | | DONE |
|
|
|
|
Plan assigned to (SAM) | 6/13/2006 | 7/3/2006 | 7/5/2006 | | PASS |
|
|
|
7/5/2006 09:44:29 SAM - activity updated through activity BLDA022 from case BLD06-01688.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/5/2006 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 7/5/2006 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 7/5/2006 | | DONE |
|
|
|
|
Telephone call | | | 7/5/2006 | | DONE |
|
|
|
spoke to alex@###-####/told permit was ready and fees associted with it
|
Routing - PLAN CHECK | 6/13/2006 | | 7/3/2006 | | PASS |
|
|
|
Plan review is done. Need Fire Department to release subdivision before I can issue plans.
|
Case Summary (BLD) | | | 7/3/2006 | | |
|
|
|
|
Application received | | | 6/13/2006 | | |
|
|
|
|
Routing - PLANNING | 6/13/2006 | | 6/13/2006 | | PASS |
|
|
|
The development agreement was for density in the airport influence area prior to platting
|
Routing - Addressing | 6/13/2006 | | 6/13/2006 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS | 6/13/2006 | | 6/13/2006 | | PASS |
|
|
|
|