Permit Information
Permit NumberBLD06-01860
StatusFinaled
Name LEVI STRAUSS AND COMPANY
Site Address 321 S 8TH ST
Project NameBODO BLDG #4
Customer Number 
ePlanReviewNo
Description
Contractor reg # RCE-10862 DEVCON CONSTRUCTION (LEVI STRAUSS & CO - BODO BLDG #4) This building is fire sprinklered for area increase. To construct a 2,635 square foot retail sales tenant space on the 1st story of "BoDo Building #4" (Northeast corner). Work is to include 2 restrooms accessible to the disabled, a fitting room accessible to the disabled, interior nonbearing walls, interior doors, millwork, and finishes. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes. The fire sprinkler system is required to comply with NFPA 13 as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
(F) Reprint permit  8/28/2007 DONE
Third Notice BLD1/8/20071/8/20071/25/2007 DONE
Second Notice has not been responded to.
Second Notice BLD12/27/200612/27/20061/8/2007 DONE
First Notice has not been responded to.
First Notice 11/2/200612/27/2006 DONE
Permanent occupancy  11/2/2006 DONE
Perm. Occ. Cert. # 11279 issued 11-2-06 to Levi Strauss & Co.
BLD-Final10/31/200611/1/200611/1/2006APASS
DetailsDave Hannah
Phone #: ###-#### ok for perm occ
Permanent Occupancy 11/1/200611/1/2006 DONE
Details
BLD-Final10/24/200610/25/200610/26/2006PPART
DetailsDave Hannah
michael; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok for temp occ needs lav in mens restroom moved
FIRE-Final Inspection10/24/200610/25/200610/25/2006APASS
DetailsForrest France
Required corrections have been made, fire life safety finaled.
Temporary occupancy  10/25/2006 DONE
Temp. Occ. Cert. # 5466 issued 10-25-06 to Levi Strauss & Co.
FIRE-Final Inspection10/23/200610/24/200610/24/2006AFAIL
DetailsTroy Cobbley
Provide suite number, exit discharge lighting at the front exit (rear exit is covered) and provide an indicator at the front exit.
BLD-Final10/19/200610/20/200610/20/2006PNR
DetailsDave Hannah
Dave I will be heading out of town around 2:00 PM. Please call Michael Jones with # above for inspection. Thanks Paul; Phone #: ###-####
FIRE-Final Inspection10/19/200610/20/200610/20/2006PFAIL
DetailsForrest France
The project related fire sprinkler permit must be finaled prior to life safety final, also missing PFE, project is not in a condition for final life safety inspection at this time.
BLD-Wall cover9/20/20069/21/20069/21/2006APASS
DetailsDave Hannah
Dave: I will need you to have look of vapor barrier and if things go ok with electrical / sprinkler inspections I'd like to cover ceilings. Thanks Paul
Case Summary (BLD)  9/21/2006 DONE
BLD-Wall cover9/13/20069/14/20069/15/2006PFAIL
DetailsDave Hannah
vapor barreir not class a
BLD-Framing/Rough-in9/12/20069/13/20069/13/2006APART
DetailsDave Hannah
see you tomorrow. ok to cover int walls
Issue PAID IN FULL permit  8/14/2006 DONE
Print Occupancy Form  8/9/2006 DONE
Telephone call  8/9/2006  
tlk to william ###-#### 102 that permit and fees are ready to be picked up but needs GC and RCE #
Permit Ready to Issue  8/9/2006  
Routing - PLANNING8/7/2006 8/8/2006 PASS
Approved per CZC06-00141.
PLANS/APPL TAKEN TO FRONT DESK  8/8/2006 DONE
Plan assigned to (CJW)7/3/2006 8/8/2006 PASS
8/8/2006 15:53:45 CJW - activity updated through activity BLDA022 from case BLD06-01860.
Routing - PLAN CHECK7/19/2006 8/7/2006 PASS
Drawings approved after resubmittal review.
Routing - FIRE8/7/2006 8/7/2006 PASS
Attached review comments to plans.
Plan resubmittals received  8/3/2006  
Received a copy of Cover letter, Plan review response letter, Plan reveiew report, 3 copies of Lighting & power Compliance, 3 copies of M-101, M-102, P-101, E-101, E-102, E-103, E-104, 2 copies of the following sheets-- G-001, A-101, A-102, A-103, A-201, A-401, A-402, A-501, A-502, A-601, and taken to Carl Westfall
Routing - FIRE7/17/2006 7/19/2006 FAIL
Faxed resubmittal item to the architect.
1st review completed  7/19/2006 FAIL
Failed Plan Check and Fire.
Routing - PLANNING7/14/2006 7/17/2006 PASS
Exterior changes. Given to Greg.
Applicant has not submitted required DR application (Zoning Cert.) - architect has been called
Plan Reviewer's activity  7/14/2006  
(7-14-06) Need the architect's E-mail address before I can send the plan review report. Called and left a message. Waiting for response. (7-17-06) The architect called and gave his E-mail address. The report was sent.
Routing - PLAN CHECK7/5/2006 7/14/2006 FAIL
The IBC plan review report was started on July 13, 2006 and was finished the next day. Revised drawings were required. See the plan review report.
Routing - PUBLIC WORKS7/3/2006 7/5/2006 PASS
Application received  6/28/2006  
Recd Pcfee & Taken To Pln CK  6/28/2006 DONE
Plans ACCEPTED BY PLAN TECH  6/28/2006