Permit Information
Permit NumberBLD06-02449
StatusFinaled
Name WILLIAM SMITH
Site Address 3214 E AMITY RD
Project Name 
Customer Number 
ePlanReviewNo
Description
(CORVARA LLC) To prepare an existing 11,360 sq. ft. warehouse (8,320 sq. ft.) & attached covered storage area (3,040 sq. ft.) building for future undefined uses per approved plans. NO TENANT DECLARED OR USE ALLOWED WITHIN THE SCOPE OF THIS PERMIT. Work includes excavation, forming, rebar placement and pouring of concrete for (7) buttress at columns of structure along the North wall and one at each end wall (East & West) per engineering details to resist outward thrust at columns when interior elevated concrete floor is removed. SPECIAL INSPECTION IS REQUIRED FOR CHEMICAL ANCHOR, HILTI HY-150, ER-5193 (copy atached to plans). After buttress' are sufficiently strong to withstand outward thrust at columns, interior demolition of existing sprinkler system, office, restrooms & associated electrical, plumbing & mechanical will be done in preparation for removal of elevated portion of concrete floor & support base (no new electrical, mechanical or plumbing were shown on plans and are not a part of this permit scope of work). New work is limited to description submitted by architect resubmittal letter, attached to plans & the zoning certificate description. This includes preparation of new compacted base and to pour new portion of interior concrete floor to provide a 'one level' floor throughout. To prepare and pour new concrete slab with compacted base under 3,040 sq. ft. covered area; remove existing stairs and doors at exterior perimeter per plan and install new lower doors in same locations to match new floor grade. To perform maintenance repair of existing standing seam metal roofing with materials to match existing; install new insulation in roof structure with minimum R-value of R-30 for metal purlin with thermal block or R-38 for metal purlin without thermal block for compliance with 802.2.4 IECC. Any Skylight replacement shall not exceed existing size and number and new skylights shall have a U-factor of .8 per Sec. 802 IECC as required by section 101.2.2.2 IECC; to infill portions of openings above lowered doors to match existing; and provide new landings at altered doors. All per approved submitted plans, declaration of limits of zoning certificate CZ06-00185, engineering and attached plan review clarifications. A "Letter of Compliance is required for this project for final approval of work. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  3/17/2010 DONE
DetailsTisha Gallop
Second Notice BLD1/9/20081/9/20082/25/2008 DONE
DetailsCathy Brown
First Notice has not been responded to.
First Notice11/14/200711/14/20071/9/2008 DONE
DetailsJim Storey
BLD-Final11/13/200711/14/200711/14/2007PPASS
DetailsJim Storey
mr smith Phone #: ###-####
DOC - Permit Finaled11/14/200711/14/200711/14/2007PPASS
DetailsJim Storey
FIRE-Final Inspection11/13/200711/14/200711/14/2007APASS
DetailsForrest France
Shell/Demo permit passed inspection.
BLD-Final11/13/200711/13/200711/13/2007PDEFR
DetailsJim Storey
mr smith Phone #: ###-#### to pm wed.
BLD-Framing/Rough-in9/24/20079/25/20079/26/2007ANR
DetailsJim Storey
Bob; Phone #: ###-#### Internet Inspection Request from: Hattie James
BLD-Framing/Rough-in9/20/20079/21/20079/21/2007ANR
DetailsJim Storey
BILL Phone #: ###-####
Print Pending Permit.LaserJet4  3/27/2007  
BLD-Aging Inspection1/30/20071/30/20071/30/2007 PASS
DetailsJim Storey
wip
BLD-Foundation11/27/200611/27/200611/27/2006PPASS
DetailsJim Storey
bob ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith pendig si.
BLD-Footing11/22/200611/22/200611/22/2006PPASS
DetailsJim Storey
bob ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith si on site for expoxy ft ok
BLD-Conference11/14/200611/15/200611/15/2006APASS
DetailsJim Storey
william; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles reviewed job site and aproved plan.
Issue PAID IN FULL permit  10/11/2006 DONE
Inspection Record Card- Bld  10/10/2006  
Telephone call  10/10/2006 DONE
tlk to mr smith ###-#### that permit and fees are ready to be picked up
Plan assigned to (DRS)9/16/20069/16/200610/9/2006 PASS
10/9/2006 13:19:37 DRS - activity updated through activity BLDA022 from case BLD06-02449.
Routing - FIRE10/5/2006 10/9/2006 PASS
Attached updated review comments to plans.
Routing - PLAN CHECK10/9/2006 10/9/2006 PASS
Inserted new site plan into the original submittals showing a fence between 3210 & 3214 Amity but stating there is not a property line there as previously indicated. Routing to permit desk to issue.
PLANS/APPL TAKEN TO FRONT DESK  10/9/2006 PASS
Approved as noted and all attached plan review conditions of all reviewing agencies.
Plan resubmittals received  10/6/2006  
received a letter from trw architecture and a project start up for special inspections. also "2" sheets of A1.1=plans taken to dan stuart
Plan resubmittals requested  10/5/2006 DONE
Faxed copy of plan review to architect Tom Williams. Items #2 & #3 were not addressed in resubmittals of 9/29/06.
Routing - PLANNING10/5/2006 10/5/2006 PASS
Approved per CZC06-00185.
Routing - PLAN CHECK9/26/2006 10/5/2006 FAIL
Inserted new submittal sheets and letters from architect into original plans. Building type of construction and original scope of work has been modified. Resubmittals did not address plan review items #2 (site plan without property line between buildings as no record of subdivision has been found or provided) & #3 (Start Up for Special Inspection form not provided). Copy of plan review faxed to Tom Williams for corrective action. Routing to fire code analyst for re-review.
Plan resubmittals received  9/29/2006  
Received 1pg. response, copy of Zoning Certificate CZC06-00185, United Water Flow information, 1pg. Fire Resistance info, 1pg. Fire Flow Requirements for Buildings, 1pg. Fire Hydrant Locations & Distribution, 2 copies of the following pages: A0.1, A0.2, A1.1, A2.1, A3.1, A4.1, S1.1, S1.2; taken to Dan Stuart
Routing - Erosion and Sediment9/27/2006 9/27/2006 PASS
ESC waiver request approved with attached conditions.
Routing - FIRE9/21/2006 9/26/2006 FAIL
Faxed resubmittal items to architect.
1st review completed  9/26/2006 FAIL
Failed planning, plan check & fire.
Plan resubmittals requested  9/21/2006 DONE
Copy of plan review sent to owner and architect for response.
Telephone call  9/21/2006 DONE
Called Stapley Engineering to review design calcs received and interpretation there of. Talked with Greg Leishman. The designer for the project would not be back in the office until tuesday or wednesday. I ask Greg to review data and plans and see if he could figure out answer to my question. He said he would or have the responsible person call when he is in.
Routing - PLAN CHECK9/14/2006 9/21/2006 FAIL
Copy of report e-mailed to owner and copy faxed to architect. Routing to fire code anlayst for his review.
Plan resubmittals received  9/20/2006 DONE
received "3" sheets including ST-1, A2.1, & A3.1- plans taked to dan stuart
Telephone call  9/20/2006 DONE
Call to Ron Sargent concerning this permit application and plans. Ron had dropped off one set of plan changes for this project as noted by Masha Smylie. I called to tell him and additional copy was required for review and to become part of plans circulating. Also left him message that plans had failed review in ESC & Planning.
Routing - PLANNING9/13/2006 9/14/2006 FAIL
Design Review application required for proposed changes to building exterior - M-1D zone.
Routing - Erosion and Sediment9/8/2006 9/13/2006 PASS
ESC plan failed, no waiver request or narrative included in submittal. Notified applicant (Ron Sargent) and e-mailed a copy of the waiver request.
Routing - PUBLIC WORKS9/8/2006 9/8/2006 PASS
Plans ACCEPTED BY PLAN TECH  8/24/2006  
Application received  8/23/2006  
Recd Pcfee & Taken To Pln CK  8/23/2006