Third Notice BLD | 5/25/2007 | 5/25/2007 | 10/12/2007 | | DONE |
|
|
|
Second Notice has not been responded to.
|
Telephone call | | | 10/4/2007 | | DONE |
|
|
|
tlk to scott rames ###-#### concerning the final values that should be ready - faxed new final sheet for him 10:20 am
|
Second Notice BLD | 5/9/2007 | 5/9/2007 | 5/25/2007 | | DONE |
|
|
|
First Notice has not been responded to.
|
First Notice | | 4/23/2007 | 5/9/2007 | | DONE |
|
|
|
|
BLD-Final | 4/10/2007 | 4/10/2007 | 4/10/2007 | P | PASS |
Mike Jordan
|
|
|
Scheduled by a contractor via Hello! on 4/10/2007 at 11:06:33 AM. Contact: ###-####. ok for perm occ. ele. Needs to final permit on computer, card was signed.
|
Permanent Occupancy | | 4/10/2007 | 4/10/2007 | | DONE |
|
|
|
|
Permanent occupancy UNPAID FEE | | | 4/10/2007 | | DONE |
|
|
|
Perm. Occ. Cert. # 11525 issued to Artisan Optics
|
BLD-Final | 4/6/2007 | 4/6/2007 | 4/6/2007 | P | CANC |
Mike Jordan
|
|
|
Scheduled by a contractor via Hello! on 4/6/2007 at 11:30:05 AM. Contact: ###-####.
|
FIRE-Final Inspection | 3/8/2007 | 3/8/2007 | 3/8/2007 | A | PASS |
Troy Cobbley
|
|
|
Life safety passed
|
BLD-Final | 3/8/2007 | 3/8/2007 | 3/8/2007 | A | PART |
Mike Jordan
|
|
|
Scheduled by a contractor via Hello! on 3/8/2007 at 6:53:38 AM. Contact: ###-####. ok temp for temp.
|
Temporary occupancy | | | 3/8/2007 | | DONE |
|
|
|
Temp.Occ. Cert. # 5552 issued 3-8-07 to Artisan Optics.
|
BLD-Final | 3/7/2007 | 3/7/2007 | 3/7/2007 | P | NR |
Mike Jordan
|
|
|
|
BLD-Final | 3/7/2007 | 3/7/2007 | 3/7/2007 | A | NR |
Mike Jordan
|
|
|
Scheduled by a contractor via Hello! on 3/7/2007 at 7:30:15 AM. Contact: ###-####. Still needs other trades.
|
FIRE-Final Inspection | 3/7/2007 | 3/7/2007 | 3/7/2007 | A | CANC |
Alan Hauser
|
|
|
Scheduled by a contractor via Hello! on 3/7/2007 at 7:19:50 AM. Contact: ###-####.
|
FIRE-Final Inspection | 3/6/2007 | 3/6/2007 | 3/6/2007 | P | CANC |
Troy Cobbley
|
|
|
waiting on fire alarm
|
FIRE-Final Inspection | 3/5/2007 | 3/5/2007 | 3/5/2007 | P | CANC |
Troy Cobbley
|
|
|
Fire alarm is not ready yet. No inspection was performed.
|
FIRE-Final Inspection | 3/1/2007 | 3/1/2007 | 3/2/2007 | P | FAIL |
Troy Cobbley
|
|
|
Need fire alarm and fire sprinkler signed off first. No inspection performed.
|
FIRE-Final Inspection | 3/1/2007 | 3/2/2007 | 3/2/2007 | A | FAIL |
Troy Cobbley
|
|
|
Need to get the sprinkler permit and fire alarm permits finaled first. No inspection performed.
|
BLD-Other | 2/9/2007 | 2/9/2007 | 2/9/2007 | P | PASS |
Mike Jordan
|
|
|
Scheduled by a contractor via Hello! on 2/9/2007 at 10:56:32 AM. Contact: ###-####. Ceiling grid. ok.
|
BLD-Energy code compliance | 12/12/2006 | 12/12/2006 | 12/12/2006 | P | PASS |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 12/12/2006 at 7:34:28 AM. Contact: ###-####. Fireblocking done.
|
BLD-Energy code compliance | 12/5/2006 | 12/5/2006 | 12/5/2006 | P | PART |
Mike Jordan
|
|
|
Scheduled by a contractor via Hello! on 12/5/2006 at 10:11:28 AM. Contact: ###-####. 1st floor interior and exterior walls, firestop not done. Will verify at grid insp.
|
BLD-Framing/Rough-in | 12/1/2006 | 12/1/2006 | 12/1/2006 | P | PASS |
Mike Jordan
|
|
|
Scheduled by a contractor via Hello! on 12/1/2006 at 9:01:00 AM. Contact: ###-####. Interior framed walls.
|
Issue PAID IN FULL permit | | | 11/28/2006 | | DONE |
|
|
|
|
Telephone call | | | 11/27/2006 | | DONE |
|
|
|
lft vm with jeff johnson ###-#### that permit and fees are ready to be picked but needs GC/RCE #
|
Permit Ready to Issue | | | 11/27/2006 | | DONE |
|
|
|
|
Print Occupancy Form | | | 11/24/2006 | | DONE |
|
|
|
|
Plan assigned to (DRS) | 9/14/2006 | | 11/22/2006 | | PASS |
|
|
|
11/22/2006 13:14:21 DRS - activity updated through activity BLDA022 from case BLD06-02534.
|
Routing - PLAN CHECK | 11/15/2006 | | 11/22/2006 | | PASS |
|
|
|
Received resubmittals from architect. New sheets inserted into plans. Plans red-lined with additional clarification not provided by architect and comments / conditions added to attached plan review report as a part of the approved plans. Taking plans to permit desk to issue.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 11/22/2006 | | PASS |
|
|
|
Approved per red-lined conditions on plans and attached plan review comments, all part of approved plans..
|
Plan resubmittals received | | | 11/21/2006 | | |
|
|
|
Received transmittal document, 1pg. response letter from Wes Steele (Arch.), 1pg. response letter from Tru Engineering, 2 copies of the following: 6pg. elevator submitals, 4pg. elevator design and finishes, A12, S-0, S-4, S-5, S-7, E-1, E-2, E-3, E-4, E-5, E1.0, E2.1, E2.2, E2.3, E3.0; taken to Dan Stuart
|
Telephone call | | | 11/15/2006 | | DONE |
|
|
|
Call from Perry Foster, Romar Electric. He had received my review report and said project could not be done in accordance with my review and pass. He said the AR1 fixtures are for lighting of art not displays for glass frames annd associated items, I told him to indicate this in his response. He said the place would be dark if he had to meet code items specified. I suggested he review with Wes Smith (Romar), wes Steele (Habitec) & tenant.
|
Routing - PLAN CHECK | 10/23/2006 | | 11/15/2006 | | FAIL |
|
|
|
Inserted new plan resubmittals of 11/13/06 into original plans. All data & information requested was not provided; new structural plans referenced additional sheets for details that were not provided; lighting compliance certificate data compared to data in light fixture schedule show differences in wattage and lamping; automatic lighting shutoff for areas over 5000 sq. ft. was indicated in compliance statement but not indicated on plans for method, equipment to be provided for complaince; an additional fixture not in compliance statement would cause compliance to fail; future display lighting indicated on E4 with 600W transformers included as part of this project but not added into certificate as the allowable watts would be exceeded.
|
Plan resubmittals requested | | | 11/15/2006 | | DONE |
|
|
|
Faxed and e-mailed copy of plan review items remaining to be addressed for code compliance. Copy also faxed to Perry Foster, Romar Electric.
|
Telephone call | | | 11/14/2006 | | DONE |
|
|
|
Called Romar Electric to talk with Wes Smith who stamped the electrical plans. Wes was not available and I talked with Perry Foster concerning the Lighting Compliance Certificate and data that would indicate the project failed energy code requirements. Perry said he had to try and provide a way to meet the requirements of the Interior Designer and the owner/tenant and they wanted all the lighting. I also asked about the future lighting specified on E4 with what appears to be 6 - 600W transformers to be installed in preparation of the future display lighting. These additional amounts would add to the actual wattage and make the project more non-compliant. I will send him copy of plan review comments after second review is completed.
|
Telephone call | | | 11/14/2006 | | DONE |
|
|
|
Called to talk with Wes Steele. He is on vacation. I talked with Brandi and I expressed I had concerns on the Lighting Compliance Certificate which appears that it should have failed. Cursory review of resubmittals raised several questions. I ask Brandi who Wes Smith is with as he stamped the electrical plans. she told me Romar Electric.
|
Plan resubmittals received | | | 11/13/2006 | | DONE |
|
|
|
Received 1 comments,2 calcs & 2 copys of sheets A0,A1,A2,A3,A4,A5,A6,A7,A12,M1.0,M2.1,M3.0,M4.0,E-1,E-2,E-3,E-4,E-5,S-1,S-2,S-4,S-6,S-8 taken to Dan S.
|
1st review completed | | | 10/23/2006 | | FAIL |
|
|
|
Failed plan check.
|
Routing - FIRE | 10/18/2006 | | 10/23/2006 | | PASS |
|
|
|
Attached revew comments to plans.
|
Plan resubmittals requested | | | 10/18/2006 | | DONE |
|
|
|
Faxed and e-mailed copy of plan review comments to Wes Steele.
|
Routing - PLAN CHECK | 9/22/2006 | | 10/18/2006 | | FAIL |
|
|
|
Resubmittals required. E-mailed and faxed copy of plan review corrections to architect. Routing plans to fire code analyst for review.
|
Routing - PLUMBING | 9/15/2006 | | 9/22/2006 | | PASS |
|
|
|
approved per plan and 2003 UPC
|
Routing - PUBLIC WORKS | 9/14/2006 | | 9/15/2006 | | PASS |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 9/1/2006 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 8/31/2006 | | |
|
|
|
|
Application received | | | 8/30/2006 | | |
|
|
|
|