Information based on query as of Thursday, July 18, 2024.
Permit Information
Permit NumberBLD06-02644
StatusFinaled
Name HC COMPANY INC
Site Address 11311 W CHINDEN BLVD
Project NameHP #7
Customer Number 
ePlanReviewNo
Description
RCE 793 HC Company Inc (HEWLETT PACKARD BLDG #7 - ASRS SAFETY RAIL - PACKAGE 1) To install a ASRS Safety rail extending above the existing roof to provide life safety support persons on the roof or working over edge of building. i.e. like window washers. Work involves installation of steel structure posts spaced per plans, attached through the roof to a new steel support beam bolted between new "C-channels" which are welded to existing steel rack vertical columns structures that support the existing roof system and also carry applied pallet loads for storage. The new beam will be laterally braced with steel 'L' shaped angle connected to an existing lateral support member connecting the existing racks. Materials will be as specified in engineering design and architectural specifications. Tthe roof will be sealed against weather per product manufacture's guidelines. Welding will be performed by qualified persons as outlined in design & specs with special inspection and review as called out in specifications and section 1704 IBC. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice BLD8/11/20088/11/20089/4/2008 DONE
DetailsCathy Brown
First Notice has not been responded to.
First Notice6/4/20086/4/20088/11/2008 DONE
DetailsJim Sly
Case Summary (BLD)  8/1/2008  
BLD-Final6/4/20086/6/20086/6/2008ACANC
DetailsJim Sly
Darrin
BLD-Conference6/4/20086/6/20086/6/2008ACANC
DetailsJim Sly
Darrin
BLD-Final6/4/20086/4/20086/4/2008PPASS
DetailsJim Sly
C/C issued.
DOC - Permit Finaled6/4/20086/4/20086/4/2008PPASS
DetailsJim Sly
BLD-Final6/4/20086/4/20086/4/2008PNR
DetailsJim Sly
Please Call 1/2 hour before arrival. Phone #: ###-#### Internet Inspection Request from: Darren Gossett
Issue PAID IN FULL permit  5/28/2008 DONE
Inspection Record Card- Bld  5/20/2008 DONE
Telephone call  5/20/2008 DONE
left vm for steve simmons at ###-#### - permit ready and fees given
Permit Ready to Issue  5/20/2008 DONE
Routing - PLAN CHECK5/16/2008 5/19/2008 PASS
DetailsDan Stuart
Resubmittals and engineering review and special inspection data provided. Attached to plans. Routing to permit desk to issue.
PLANS/APPL TAKEN TO FRONT DESK  5/19/2008 PASS
Routing - PLAN CHECK10/25/2006 5/19/2008 PASS
DetailsDan Stuart
Resubmittals and structural engineers and special inspection services and approvals provided. Project was completed under roofing permit. Required third party verification of compliance with engineers design. To permit desk to issue.
Plan assigned to (DRS)9/25/2006 5/19/2008 PASS
DetailsDan Stuart
5/19/2008 15:58:45 DRS - activity updated through activity BLDA022 from case BLD06-02644.
Plan resubmittals received  5/16/2008  
DetailsDan Stuart
Received 1 cover letter dated 5-16-08 from Steven Simmons, 1 copy of letter dated 3-5-08 from Dan Stuart, 1 copy of plan review report dated 10-20-06, 1 copy of Response to Structural Plan Review Comments dated 5-15-08 from CH2M Hill, 1 copy of Project Start up for Special Inspections, 1 copy of Responses to Pre-Bid Questions dated 8-3-06, 1 copy of High Strength Bolting Report and taken to Dan Stuart///5-16-08 @ 9:57am BAS
Telephone call  9/7/2007 DONE
Call to Steve simmins, LCA, and Bret Dillon, HP to see if this project is dead or resubmittals will be forthcoming. Left voice message to call me back.
Plan Reviewer's activity  4/5/2007 DONE
E-mail to Steve Simmons concerning the current status of this project. After 180 days the permit will be voided.
Telephone call  4/5/2007 DONE
E-mail I sent had come back as undeliverable. I called Steve to ask about e-mail address and project. He had changed his e-mail address and had not received the plan review of 10/20/06. He said he had not received the fax either. Sent him another e-mail copy of review. He e-mailed back he received it.
Routing - FIRE10/20/2006 10/25/2006 PASS
Attached review comments to plans.
1st review completed  10/25/2006 FAIL
Failed plan check.
Plan resubmittals requested  10/20/2006 DONE
Routing - PLAN CHECK9/25/2006 10/20/2006 FAIL
Copy of plan review e-mailed and faxed to Steve simmons, architect. Routing to fire code analyst for review.
Routing - PUBLIC WORKS9/25/2006 9/25/2006 PASS
Plans ACCEPTED BY PLAN TECH  9/14/2006  
Recd Pcfee & Taken To Pln CK  9/14/2006 DONE
Application received  9/13/2006