Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD06-02735
StatusExpired
Name REAL ESTATE SHOWROOM
Site Address 350 N MILWAUKEE ST Unit: 2310
Project NameBTS - #2310
Customer Number 
ePlanReviewNo
Description
ALLIANCE EQUITY BUILDERS RCE #17432 (Real Estate Showroom - Boise Towne Square - Space 2310) To remodel an existing 2,313 sq ft tenant space located on the second floor per approved plans. Work to include, new finishes to existing storefront framing, construction of new noncombustible partitions to create showroom areas, new floor finish, misellaneous related interior finishes, existing lighting and ceiling to remain the same, this building is fully fire sprinklered and contains a smoke evacuation system, any alterations to the sprinkler system WILL require a separate permit and shall be installed per NFPA #13 as regulated by the fire department. The smoke evacuation system is to remain operational as originally installed under the 1985 UBC. RMH
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Conference4/1/20084/1/20084/1/2008PPASS
DetailsMike Jordan
DOC - Permit Expired4/1/20084/1/20084/1/2008PPASS
DetailsMike Jordan
The tenant is no longer in this space.
BLD-Framing/Rough-in10/13/200610/16/200610/16/2006APASS
DetailsMike Jordan
mike; Phone #: ###-#### Internet Inspection Request from: Patricia Smith. Interior partitions were repaired and made non-combustible.
FIRE-Final Inspection10/12/200610/13/200610/13/2006AFAIL
DetailsTroy Cobbley
repair the exit signs and emergency lights, provide an exit sign at the transitiona wall between the open office and rear offices, provide a current inspection tag for the fire extinguisher, test the smoke evac system with the inspector and provide missing ceiling tiles.
BLD-Framing/Rough-in10/12/200610/13/200610/13/2006AFAIL
DetailsMike Jordan
Mike; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt. Plywood used in interior framed walls. Type 2 const. required, no combustibles allowed.
Issue PAID IN FULL permit  10/6/2006 DONE
Plan assigned to (R_H)9/26/2006 9/26/2006 PASS
9/26/2006 13:49:27 RMH - activity updated through activity BLDA022 from case BLD06-02735.
Routing - PLAN CHECK9/26/2006 9/26/2006 PASS
Routing - FIRE9/26/2006 9/26/2006 PASS
Minor remodel / field verify
Case Summary (BLD)  9/26/2006 DONE
1st review completed  9/26/2006  
PLANS/APPL TAKEN TO FRONT DESK  9/26/2006 DONE
Case Summary (BLD)  9/26/2006  
Print Occupancy Form  9/26/2006 DONE
Telephone call  9/26/2006 DONE
lft vm with paul lawrence ###-#### that permit and fees are ready to be picked up but needs RCE/GC
Permit Ready to Issue  9/26/2006 DONE
Plans ACCEPTED BY PLAN TECH  9/25/2006  
Application received  9/22/2006  
Recd Pcfee & Taken To Pln CK  9/22/2006