Permit Information
Permit NumberBLD06-03277
StatusFinaled
Name KREIZENBECK CONSTRUCTORS
Site Address 7701 NORTHVIEW
Project NameFairmont Park Elementary
Customer Number 
ePlanReviewNo
Description
(Fairmont Park Elementary School) To construct a 58,243 sq. ft. one story type IIIB fully fire sprinkled elementary school. Other work includes site improvements, paving and landscaping per approved plans and attachments, CUP06-00071. Fire sprinklers used for area.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice BLD9/22/20089/22/200812/22/2008 DONE
DetailsCathy Brown
First Notice has not been responded to.
First Notice 8/13/20089/22/2008 DONE
BLD-Final8/13/20088/13/20088/13/2008PPASS
DetailsJim Sly
David Phone #: ###-####
OK for Perm Occ.
Permanent Occupancy  8/13/2008  
BLD-Final7/25/20087/25/20087/25/2008APART
DetailsJim Sly
OK for Temp Occ. Need Letter from special insp agency and Engineer of record.
Temporary Occupancy7/25/200810/23/20087/25/2008 DONE
DetailsTisha Gallop
Building inspector needs letter from the engineer and Strata prior to perm occupancy
BLD-Final7/21/20087/21/20087/14/2008ADONE
DetailsLori Flook
inspected per SLandaluce 7/14/08.
BLD-Framing/Rough-in7/9/20087/10/20087/10/2008PDONE
DetailsJim Sly
David Phone #: ###-####
Code Occupancy Approval7/9/20087/9/20087/9/2008PPASS
DetailsCarol Montgomery
Insp. @ 2:00-2:15; Phone #: ###-####

Meets compliance with CUP. Signed Occupancy card FINAL
FIRE-Final Inspection7/3/20087/7/20087/7/2008APASS
DetailsTroy Cobbley
Life safety completed per notes of last inspection.KR
FIRE-Final Inspection6/26/20086/27/20086/27/2008AFAIL
DetailsForrest France
All testing completed. Could not pass until kitchen hood system permit is finaled. KR
BLD-Final4/10/20084/11/20084/11/2008ANR
DetailsJim Sly
Reviewed Requirements to obtain final.
BLD-Other3/27/20083/27/20083/27/2008PPASS
DetailsJim Sly
Scheduled by a contractor via Hello! on 3/27/2008 at 9:09:08 AM.
OK'd 1hr Celing in Mechanical room.....in leiu of walls continuing up to roof deck. Rm at North side of bldg
BLD-Conference3/20/20083/21/20083/21/2008PNR
DetailsJim Sly
Ceiling grid.....Need Fire approval Need 1 slack wire on all appliances...ie HVAC diffusers.
BLD-Other3/20/20083/20/20083/20/2008PCANC
DetailsJim Sly
nacho - ceiling grid Phone #: ###-####
Need fire sprinkler approval
BLD-Conference3/19/20083/19/20083/19/2008PDONE
DetailsJim Sly
Nacho Phone #: ###-####
Walk thru with Nacho.......checked wood trusses.....OK Metal Trusses in Gym questioned ........Capable of carrying extra load from basketball standards....OK'd. Looked at insulation and scrim covering....will come back later to take a better look.
Telephone call  2/28/2008 DONE
I called Justin Schwartz ###-####, inquiring on the status of the eave sprinkler Modification request we discussed last week; Per Mark Senteno, the FD hasn't received a letter from him. Not available, left voice message to call me.
Telephone call  2/20/2008 DONE
Telcon from Justin Schwartz, Hummel Arch's regarding the eave soffits which have a clear space between the top and botton chord of 7" (just over 1" greater than the code exception for sprinkler protection o fless than 6"). I suggested he could write Dave Hanneman, requesting special design approval based on several factors of the situation, and see if those factors might be considered sufficient for equivalency of intent and protection of occupants and fire fighters. If this is not approved, an alternative would be to add a nominal 2"x2" to the top or botton chord to reduce the space to less than 6".
BLD-Conference2/14/20082/14/20082/14/2008PDONE
DetailsTroy Cobbley
I did a quick walk through while waiting for the sprinkler underground flush and found the t-bar is being installed as well as some ceiling tiles/lights. I notified the project superintendant that no ceiling are to be installed or sprinkler piping to be covered since the sprinkler system has not been inspected yet. Jim Sly the structural inspector has also been notified.
Third Notice BLD12/22/200812/22/20082/13/2008 DEFR
DetailsRita DeYoung
Second Notice has not been responded to. Brandon called to say he should have his paper work done in March.
BLD-Framing/Rough-in12/3/200712/4/200712/4/2007APART
DetailsJim Sly
Scheduled by a contractor via Hello! on 12/3/2007 at 3:23:59 PM. Contact: ###-####.
interior classroom walls...... and select walls ok.
BLD-Framing/Rough-in10/22/200710/23/200710/23/2007APART
DetailsMike Jordan
Scheduled by a contractor via Hello! on 10/22/2007 at 5:14:34 PM. Contact: ###-####. Nailing for roof diaphragm, low roofs only.
BLD-Foundation6/26/20076/26/20076/26/2007PPART
DetailsJim Sly
Scheduled by a contractor via Hello! on 6/26/2007 at 7:30:13 AM. Contact: ###-####.
OK pending STRATA SPECIAL INSP, TESTS and approvals
BLD-Foundation6/22/20076/22/20076/22/2007PPART
DetailsJim Sly
Scheduled by a contractor via Hello! on 6/22/2007 at 7:28:45 AM.
In/terior footings............STRATA
BLD-Foundation6/18/20076/20/20076/20/2007APART
DetailsJim Sly
Scheduled by a contractor via Hello! on 6/18/2007 at 11:33:50 AM. Contact: ###-####.
Interior footings...........OK pending STRATA insp, tests, and approvals.
BLD-Foundation5/31/20076/1/20076/1/2007APART
DetailsJim Sly
Scheduled by a contractor via Hello! on 5/31/2007 at 12:26:41 PM. Contact: ###-####.
OK pend STRATA insp and appr.

BLD-Foundation5/29/20075/30/20075/30/2007APART
DetailsJim Sly
Scheduled by a contractor via Hello! on 5/29/2007 at 12:54:18 PM.
OK pend STRATA insp and appr.
BLD-Foundation5/17/20075/21/20075/21/2007APART
DetailsJim Sly
Scheduled by a contractor via Hello! on 5/17/2007 at 1:35:44 PM. Contact: ###-####.
OK pending STRATA insp, tests, and approvals
BLD-Foundation5/15/20075/18/20075/18/2007APART
DetailsJim Sly
Scheduled by a contractor via Hello! on 5/15/2007 at 1:06:41 PM. Contact: ###-####.
Footings at South East area....section C OK pending STRATA special insp, tests, and approvals.
BLD-Foundation5/15/20075/17/20075/17/2007APART
DetailsTony Young
Scheduled by a contractor via Hello! on 5/15/2007 at 1:05:56 PM. Contact: ###-####.
ok pending S. I. report
BLD-Foundation5/15/20075/16/20075/16/2007APART
DetailsJim Sly
Scheduled by a contractor via Hello! on 5/15/2007 at 1:05:14 PM. Contact: ###-####.
Footings ... South wall OK pending STRATA special inspection, tests, and approvals.
(F) Reprint permit  4/13/2007  
Issue PAID IN FULL permit  4/12/2007 DONE
Plan assigned to (MLO)11/20/2006 3/29/2007 PASS
3/29/2007 11:37:18 MLO - activity updated through activity BLDA022 from case BLD06-03277.
Routing - PLAN CHECK3/29/2007 3/29/2007 PASS
Routing Off Site - STRUCTURAL3/20/2007 3/29/2007 PASS
Called Action Courier for pick up on 3/20/07 @ 9:50am///BAS Called Jan Welch and got verbal approval over phone. MLO
PLANS/APPL TAKEN TO FRONT DESK  3/29/2007 DONE
Print Occupancy Form  3/29/2007 DONE
Telephone call  3/29/2007 DONE
t/c w margie kennedy at ###-#### - permit ready and fees given - also need ACHD - margie said that since it is a school they do not have to pay the fees - she will bring something in writing to that effect - faxed her a copy of the fees to show the school dist.
Permit Ready to Issue  3/29/2007  
Plan resubmittals received  3/15/2007  
Received transmittal letter, 3 copies of Structural Calculations, and 3 copies of page S1.02A; taken to Mike Otto
Plan resubmittals received  3/14/2007 FAIL
received copy of fax sent to our engineer which includes corrected plan sheet. Sent email to architect telling them to provide not less than two full size plan sheets stamped and signed by the engineer.
Routing Off Site - STRUCTURAL3/5/2007 3/13/2007 FAIL
Called Action Courier for pick up @ 12:10pm BAS Engineer has been in direct contact with design engineer about corrections.
Plan resubmittals received  3/2/2007 DONE
Received 1 transmittal letter, 3 structural calcs and 3 copys of sheets S1.02A,S1.02B,S5.02,S6.01,S6.02,S6.03,S6.04 taken to Mike Otto
Routing - PUBLIC WORKS2/21/2007 2/22/2007 PASS
Plan resubmittals requested  2/15/2007 DONE
structural corrections
Routing Off Site - STRUCTURAL1/30/2007 2/15/2007 FAIL
called action couriers for pick up 1-30-07 corrections sent to architect
Routing - PUBLIC WORKS2/7/2007 2/8/2007 PASS
Routing - PLAN CHECK2/5/2007 2/6/2007 PEND
pending structural approval
Plan resubmittals received  2/2/2007  
rec'd transmittal letter, door hardware packet - 3 sets of sheet #A2.07 - taken to Mike Otto
Routing - PUBLIC WORKS1/31/2007 2/1/2007 FAIL
Bad location for trash. No way for truck to exit without backing out blindly. Contact Pam Williams ###-####
Routing - PLAN CHECK2/1/2007 2/1/2007  
Routing - PLAN CHECK1/23/2007 1/30/2007 FAIL
need revised sheet A2.07, fire protection exterior struc members and panic hardware door 208. Called architect went over corrections.
Plan resubmittals requested  1/30/2007 DONE
IBC corrections
Plan resubmittals received  1/22/2007 DONE
rec'd 1 transmittal cover, 1 2pg response letter, 2 copies of plan review comments from Lochsa Engineering, 2 copies of sheet #s A0.10, A2.02, A2.03, A2.04, A2.21, A5.00, A5.01, A5.02, A5.03, A5.04, A5.05, A5.06, A5.07, A5.09, A5.10, A5.11; 2 copies of sheet #s S0.1, S1.01, S1.01A, S1.01B, S1.01C, S1.02, S1.02A, S1.02B, S1.02C, S1.03, S1.03A, S1.03B, S1.03C, S2.01, S2.02, S3.01, S3.02, S3.03, S4.01, S5.01, S5.02, S6.01, S6.02, S6.03, S6.04, S7.01 - taken to Mike Otto
Routing - FIRE12/15/2006 12/20/2006 PASS
Attached fire review comments to plans.
1st review completed  12/20/2006 FAIL
Failed structural and plan check.
Routing - PLAN CHECK12/20/2006 12/20/2006  
Plan resubmittals requested  12/15/2006 DONE
IBC corrections
Routing - PLAN CHECK12/11/2006 12/15/2006 FAIL
corrections sent to architect
Routing Off Site - STRUCTURAL11/20/2006 12/11/2006 FAIL
Called Action Courier for pick up @ 11:52am///11/20/06 BAS corrections sent to architect. MLO
Routing - PLANNING12/5/2006 12/8/2006 PASS
CUP06-00071--Susan Riggs
Routing - PLUMBING11/29/2006 12/5/2006 PASS
min. 2" waste piping below slab. details on page P1.4 show 2" waste to the toilets, 3" min. P-5 is a janitor sink, 3" waste detail shows 1 1/2". all fixtures used for food prep or utensil washing must be indirectly wasted, sink in snack room 207 needs to be wasted into a floor sink. use boise city approved grease interceptor detail, atrtached.
Routing - Erosion and Sediment11/28/2006 11/29/2006 PASS
ESC plan approved with attached conditions.
Routing - PUBLIC WORKS11/22/2006 11/28/2006 FAIL
Street lighting plan required for entrances on Northview St. Contact Hank A. at ###-####
Routing - PLANNING Land Div11/20/2006 11/22/2006 PASS
Approved, parcel is over 5 acres in size.
Plans ACCEPTED BY PLAN TECH  11/20/2006  
Plan routing begun/NEW & ADDTN  11/20/2006  
Pending Assignment by MYS11/17/2006 11/20/2006 DONE
11/20/2006 11:23:47 JCM - activity updated through activity BLDA174 from case BLD06-03277.
Recd Pcfee & Taken To Pln CK  11/17/2006  
Application received  11/17/2006