BLD-Final | 2/16/2010 | 2/17/2010 | 2/17/2010 | A | PASS |
Tom Arcoraci
|
|
|
Justin- ###-####- call for access CO issued left on counter
|
DOC - Permit Finaled | 2/17/2010 | 2/17/2010 | 2/17/2010 | P | PASS |
Tom Arcoraci
|
|
|
|
CHANGE STATUS TO (ISS) | | | 2/16/2010 | | DONE |
|
|
|
|
BLD-Framing/Rough-in | 5/24/2007 | 5/24/2007 | 5/24/2007 | P | PASS |
Mike Jordan
|
|
|
jeff ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith. Winders are now code compliant.
|
BLD-Framing/Rough-in | 5/21/2007 | 5/21/2007 | 5/21/2007 | P | PART |
Mike Jordan
|
|
|
jeff; Phone #: ###-#### Internet Inspection Request from: Victoria Beall. All issues have been resolved except for stairs. wip onm stairs, contracctor to reschedule additional insp. for stairs. Also performed energy insp. ok. ok to start hanging rock except at stairs.
|
BLD-Framing/Rough-in | 5/15/2007 | 5/16/2007 | 5/16/2007 | A | FAIL |
Mike Jordan
|
|
|
c/n posted. ok to insul. 1. nail off all simpson hangars. 2. repair top plate in garage at gas piping. 3. provide min 3nails for truss to top plate connection. 4. provide min 4 8d nails on straps either side. 5. header required upstairs at doorway were truss bearing occurs. 6. provide fireblocking at furouts. 7. foam seal tub drain at main floor. 8. provide engineering for portal frame. 9. provide code compliant winder stairs. Must be within 3/8 inch of other treads at 12" walk line.
|
BLD-Framing/Rough-in | 5/15/2007 | 5/15/2007 | 5/15/2007 | P | CANC |
Dave Hannah
|
|
|
Jeff; Phone #: ###-#### Internet Inspection Request from: Victoria Beall out of time rescheduled for tomorrow am
|
BLD-Framing/Rough-in | 5/11/2007 | 5/11/2007 | 5/11/2007 | P | FAIL |
Mike Jordan
|
|
|
jeff ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith. No approved plans or truss engineering on site. Winder treads on stairway are non code copmpliant,
|
BLD-Footing | 3/6/2007 | 3/6/2007 | 3/6/2007 | P | PASS |
Mike Jordan
|
|
|
justin; Phone #: ###-#### Internet Inspection Request from: Stacie Backus
|
Issue PAID IN FULL permit | | | 3/2/2007 | | |
|
|
|
|
Receive PAYMENT IN FULL | | | 3/1/2007 | | DONE |
|
|
|
|
(F) Reprint permit | | | 3/1/2007 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 2/23/2007 | | DONE |
|
|
|
|
Telephone call | | | 2/23/2007 | | DONE |
|
|
|
left vm for justin jayo at ###-#### - permit ready and fees given
|
Permit Ready to Issue | | | 2/23/2007 | | |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 2/22/2007 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 2/22/2007 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 2/22/2007 | | DONE |
|
|
|
|
Pending Assignment by SRZ | 1/8/2007 | | 2/22/2007 | | DONE |
|
|
|
2/22/2007 12:33:27 DJO - activity updated through activity BLDA169 from case BLD07-00051.
|
Routing - PLAN CHECK | 1/9/2007 | | 2/22/2007 | | PASS |
|
|
|
|
Routing - PLANNING | 1/8/2007 | | 1/9/2007 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS | 1/9/2007 | | 1/9/2007 | | PASS |
|
|
|
|
Routing - Addressing | 1/8/2007 | | 1/8/2007 | | PASS |
|
|
|
|
Application received | | | 1/8/2007 | | |
|
|
|
|
Plan assigned to (DJO) | 2/22/2007 | 2/22/2007 | | | |
|
|
|
|