Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD07-00277
StatusFinaled
Name TRADEWINDS BUILDING COMPANY
Site Address 13014 W PERSIMMON LN
Project Name13014 W PERSIMMON LN
Customer Number 
ePlanReviewNo
Description
(Dr. Rod Emory Dental Office) 6/19/07- PLAN MODIFICATION. TO ADD AN ADDITIONAL 418 SQ. FT. TO THE ORIGINAL 3,296 SQ. FT. DENTAL OFFICE TO ADD 3 ADDITIONAL OPERATORY AREAS (10/24/07 Letter from architect declares addition to be built but not finished at this time. Utilities to be roughed in but no fixture's or equipment at this time) TOTAL SQUARE FOOTAGE IS 3,714 SQ. FT. NO CHANGES TO BASEMENT AREA. NEW ADDITION OVER CRAWL SPACE. ORIGINAL PLAN REVIEW CONDITIONS OF ALL AGENCIES STILL ARE APPLICABLE UNLESS MODIFIED AS PART OF THE PLAN MODIFICATION. To construct a 3,714 (3,296) sq ft one story Type VB dentist office with a 802 sq ft basement. Other work includes all site improvements, paving and landscaping per approved plans and attachments, CU99-0086, DRH06-00443. (mlo)
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice BLD12/11/200712/11/200712/26/2007 DONE
Second Notice has not been responded to.
Second Notice BLD11/13/200711/13/200712/11/2007 DONE
First Notice has not been responded to.
First Notice 10/30/200711/13/2007 DONE
BLD-Final10/29/200710/30/200710/30/2007APASS
DetailsTom Arcoraci
troy Phone #: ###-####
Permanent Occupancy UNPAID FEE  10/30/2007 DONE
(F) Reprint permit  10/26/2007  
Temporary Occupancy UNPAID FEE  10/19/2007 DONE
BLD-Final10/18/200710/18/200710/18/2007PPART
DetailsJim Sly
Troy, call 1st = ); Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
OK for temp Occ. OK for Perm when Plubing Perms.
FIRE-Final Inspection10/17/200710/17/200710/17/2007PPASS
DetailsTroy Cobbley
LIfe safety passed.
Code Occupancy Approval10/17/200710/17/200710/17/2007PPASS
DetailsCarol Montgomery
Meets compliance with CU99-0086 and DRH06-00443. PASS.
FIRE-Final Inspection10/16/200710/16/200710/16/2007PFAIL
DetailsTroy Cobbley
Provide a tagged fire extinguisher in the basement and upstairs, provide an additional exit sign upstairs as discussed and shown on the approved plans and provide emergency lighting and exit sign as per the approved plans in the basement and the exterior stairwell.
BLD-Other10/2/200710/2/200710/2/2007PPASS
DetailsJim Sly
troy Note ceiling Phone #: ###-####
BLD-Energy code compliance8/1/20078/2/20078/2/2007PPASS
DetailsJim Sly
troy Phone #: ###-####
BLD-Framing/Rough-in7/26/20077/26/20077/26/2007PPASS
DetailsTom Arcoraci
troy; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang
BLD-Conference7/23/20077/23/20077/23/2007APASS
DetailsTom Arcoraci
BLD-Other7/19/20077/20/20077/20/2007PPASS
DetailsJim Sly
troy Note: shear Phone #: ###-####
Ext shear nailing OK
Plan assigned to (DRS)6/20/20076/20/20077/10/2007 PASS
7/10/2007 07:30:20 DRS - activity updated through activity BLDA022 from case BLD07-00277.
Routing - PLAN CHECK7/9/2007 7/10/2007 PASS
Plan Modification for addition to original project has been reviewed and approved by original reviewing agencies - fire, plumbing, planning, PW & building code. Plans to permit desk to issue.
Override - Parcel Holds  7/10/2007  
PLANS/APPL TAKEN TO FRONT DESK  7/10/2007 PASS
PLAN MODIFICATION
Print Occupancy Form  7/10/2007 DONE
Telephone call  7/10/2007 DONE
t/c w oscar at ###-#### - permit ready and fees given
Permit Ready to Issue  7/10/2007  
Issue PAID IN FULL permit  7/10/2007 DONE
Routing - FIRE7/2/2007 7/9/2007 PASS
Attached updated review comments to plans.
Routing - PLAN CHECK6/21/2007 7/2/2007 PEND
Plan back from Plumbing. Routing to fire code analyst for review of plan modification.
Override - Parcel Holds  7/2/2007  
Routing - PLUMBING6/20/2007 7/2/2007 PASS
backwater valve required on basement fixtures. pipe island sink vents per upc 909 and 905.
Routing - PUBLIC WORKS6/27/2007 6/28/2007 PASS
Routing - PLANNING6/26/2007 6/27/2007 PASS
Routing - FIRE6/20/2007 6/21/2007 PASS
Attached updated review comments to plans.
Override - Parcel Holds  6/20/2007  
Plan Reviewer's activity  6/20/2007 DONE
Plan modification application and new plans provided for review. Plans routing to 1) Planning 2) Public works 3) Plumbing 4)Plan Check 5) Fire. Original permit modified to reflect proposed changes, adding 418 additional square feet to original 3,296 sq. ft. with crawl space for three additional Operatory areas. Routing to Planning.
Plan Modification Accepted  6/19/2007  
Plan modification accepted for Bld07-00277 to construct an additional 418 sq.ft. to the existing building currently under construction; submitted on pages A0, A1.0, A2.0, A2.1, A3.0, A4.0, A5.0, A6.0, S0, L1, E1.0, E2.0, E3.0, E4.0, M0.0, M0.1, P1.0, P1.1, P1.2, P2.1, H1.0, H1.1, H2.1, and revised cert of value; routed to Dan Stuart
BLD-Foundation5/29/20075/30/20075/30/2007PPASS
DetailsJim Sly
jack ; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
BLD-Footing5/25/20075/29/20075/29/2007PPART
DetailsJim Sly
jack; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
Footing for crawl area......OK.
BLD-Foundation5/17/20075/18/20075/18/2007APART
DetailsJim Sly
Scheduled by a contractor via Hello! on 5/15/2007 at 1:06:41 PM. Contact: ###-####.
Footings at Southeast ...section C OK pending STRATA special insp, tests, and approvals.
BLD-Footing5/11/20075/14/20075/14/2007PPART
DetailsMike Jordan
JACK; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. wip. Tieing steel in place at time of insp.
(F) Reprint permit  4/27/2007  
Override - People Holds  4/26/2007  
Issue PAID IN FULL permit  4/26/2007 DONE
OVERRIDE  4/16/2007  
Plan assigned to (DRS)4/9/20074/13/20074/16/2007  
DetailsDan Stuart
Re assigned to Dan Stuart after Mike Otto left employeement with Boise City.
Additional plans submitted  4/16/2007 DONE
Received two 8-1/2" x 11" plan sheet details for Restroom #114, Door #13 & Restroom #102, door #3. Door #3 now swings out for accessiblity compliance and the counter in Room 114 has been reduced in size and the sink location adjusted to provide the 18" latch side clearance and the 60" perpendicular clear at door #13. Red-lined on plan sheet A3.0 and attached copies of plan details from architect to plans.
PLANS/APPL TAKEN TO FRONT DESK  4/16/2007 PASS
Approved as noted on and all attached review conditions of all reviewing agencies.
Print Occupancy Form  4/16/2007 DONE
Telephone call  4/16/2007 DONE
left message for larry knopp w oscar at ###-#### - permit ready and fees given
Override - People Holds  4/16/2007  
Permit Ready to Issue  4/16/2007 DONE
Routing - PLAN CHECK4/16/2007 4/16/2007 PASS
Received new 8-1/2" x 11" details for restrooms 102 & 114 showing correct clearances at doors for accessiblity. Plans red-lined and copies of new details attached to plans.
Plan assigned to (MLO)2/5/2007 4/16/2007 PASS
4/16/2007 09:28:17 DRS - activity updated through activity BLDA022 from case BLD07-00277.
Plan Reviewer's activity  4/13/2007 DONE
Inserted all previous plan resubmittals into plans. Reviewed items requested to be submitted by Mike Otto on 3/26/07. Made notes on plans and called architect to discuss accessibility clear floor area at doors 102 & 114 inside restrooms. Waiting for response.
Telephone call  4/13/2007 DONE
Call to Oscar and Ross Holloway, LRK Architects. discussed clearances at doors 102 & 114 and possible solutions, He will review with larry Knopp and get back with me.
Routing - PLAN CHECK4/9/2007 4/13/2007 PEND
Items on plans not correct for accessibility at restrooms 102 & 114. Other items red-lined on plans for field verification by contractor and inspectors.
Plan resubmittals received  4/4/2007  
Received 1 cover transmittal, 2 copies of sheets, A1.0, A2.0, A3.0, A5.0, A7.0, A10.0, L1 and taken to Mike Otto
Plan resubmittals requested  3/26/2007 DONE
IBC corrections
Routing - PLAN CHECK3/22/2007 3/26/2007 FAIL
corrections sent to architect
Plan resubmittals received  3/21/2007  
Received 1pg. letter of response and 2 copies of the following pages: A0, A2.0, A2.1, A3.0, A4.0, A5.0, A6.0, A8.0, A8.1, A9.0, A10.0, E2.0, E3.0, E4.0, P1.1, H1.1; taken to Mike Otto
Routing - FIRE2/26/2007 3/1/2007 PASS
Emailed architect review comments and attached review comments to plans.
1st review completed  3/1/2007 FAIL
Failed plan check.
Plan resubmittals requested  2/23/2007 DONE
IBC corrections
Routing - PLAN CHECK2/15/2007 2/23/2007 FAIL
corrections sent to architect
Routing - PLANNING2/15/2007 2/15/2007 PASS
Approved per drh06-00443
Routing - PLUMBING2/8/2007 2/15/2007 PASS
additional cross connection may be required, pipe mop sink to sewer. 120 deg. max to public lavs. piping for the sprinkler head in the gas room must be protected by a dcva, all downstream piping to be installed by a fire sprinkler contractor.
Routing - Erosion and Sediment2/8/2007 2/8/2007 PASS
ESC plan approved with attached conditions.
Routing - PUBLIC WORKS2/5/2007 2/8/2007 PASS
Routing - PLANNING Land Div2/5/2007 2/5/2007 PASS
Plan routing begun/NEW & ADDTN  2/5/2007  
Pending Assignment by MYS2/1/2007 2/5/2007 DONE
2/5/2007 08:49:29 JCM - activity updated through activity BLDA174 from case BLD07-00277.
Plans ACCEPTED BY PLAN TECH  2/5/2007  
Application received  2/1/2007  
Recd Pcfee & Taken To Pln CK  2/1/2007