Routing - PLAN CHECK | 3/2/2007 | | 3/20/2009 | | FAIL |
Dan Stuart
|
|
|
Resubmittals required. Copy of plan review e-mailed to architect. Routing to fire code anlyst for review.
|
Third Notice BLD | 10/1/2007 | 10/1/2007 | 2/27/2009 | | DONE |
Patricia Smith
|
|
|
Second Notice has not been responded to.
|
Meeting | | | 2/27/2009 | | DONE |
|
|
|
no final cert of value ever received - signed off per RAD
|
Second Notice BLD | 9/13/2007 | 9/13/2007 | 10/1/2007 | | DONE |
|
|
|
First Notice has not been responded to.
|
First Notice | | 8/8/2007 | 9/13/2007 | | DONE |
|
|
|
|
Permanent Occupancy | | | 8/8/2007 | | DONE |
|
|
|
|
BLD-Final | 6/29/2007 | 6/29/2007 | 6/29/2007 | P | PASS |
Jim Sly
|
|
|
bill - pls call 30 mins prior; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang OK for Perm Occ
|
FIRE-Final Inspection | 6/27/2007 | 6/28/2007 | 6/28/2007 | A | PASS |
Troy Cobbley
|
|
|
Life safety finaled. There were no fire alarm modifications per the general contractor.
|
BLD-Other | 6/25/2007 | 6/25/2007 | 6/25/2007 | P | PASS |
Jim Sly
|
|
|
Bill, ceiling grid inspection, please call 1st for access = ); Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
|
BLD-Framing/Rough-in | 5/25/2007 | 5/25/2007 | 5/25/2007 | P | PASS |
Jim Sly
|
|
|
bill Note: please call for key code; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD-Energy code compliance | 5/15/2007 | 5/15/2007 | 5/15/2007 | P | PASS |
Jim Sly
|
|
|
Bill - pls call for entrance code; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
|
BLD-Framing/Rough-in | 5/14/2007 | 5/14/2007 | 5/14/2007 | P | PASS |
Mike Jordan
|
|
|
bill-pls call for key code if door is locked; Phone #: ###-#### Internet Inspection Request from: Victoria Beall. Interior framed walls. insul on shell was nearly complete, installing vapor barrier. Needs to make sure to keep 2hr around riser room.
|
Telephone call | | | 4/16/2007 | | DONE |
|
|
|
Call from Eric Stole, plumbing inspector, concerning service sink. I had noted on the plan review comments that one was required and one was indicated on plans sheet 2). I thought it was at the end of the breakroom millwork on original plans. Eric showed them the note indicating one was needed and suggested they contact the architect for location.
|
Issue PAID IN FULL permit | | | 4/12/2007 | | DONE |
|
|
|
|
Plan assigned to (DRS) | 2/27/2007 | | 4/6/2007 | | PASS |
|
|
|
4/6/2007 09:23:57 DRS - activity updated through activity BLDA022 from case BLD07-00392.
|
Routing - PLAN CHECK | 4/5/2007 | | 4/6/2007 | | PASS |
|
|
|
Received call from Chris Anderson, Architect. Fire alarm certificate of value briken out of electrical value is $3,000.00. Red-lined on CV with $3,000 subtracted from electrical $13,495.00 = $10,495.00 electrical. To permit desk to issue.
|
Telephone call | | | 4/6/2007 | | DONE |
|
|
|
Call from Chris Anderson. Break out value for fire alarm is $3,000.00. Changed electrical total to $10,495.00. Red-lined on certificate.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 4/6/2007 | | PASS |
|
|
|
|
Print Occupancy Form | | | 4/6/2007 | | DONE |
|
|
|
|
Telephone call | | | 4/6/2007 | | DONE |
|
|
|
t/c w chris anderson at ###-#### - permit ready and fees given - also need gc name and rce#
|
Permit Ready to Issue | | | 4/6/2007 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 3/23/2007 | | 4/5/2007 | | PASS |
|
|
|
Inserted resubmittals of 3/30/07 into plans and remaining resubmittals of 4/5/07 into plans & reviewed. Preparing to take to permit desk.
|
Plan resubmittals received | | | 4/5/2007 | | DONE |
|
|
|
Received 1 transmittal letter, and 2 copys of sheets E0.0,E0.1,E2.1,E2.2P,E3.0 taken to Dan S.
|
Telephone call | | | 4/5/2007 | | DONE |
|
|
|
Phone call to Chris Anderson, Rudeen & Assoc. asking for certificate of value breaking out the cost of the fire alarm from the electrical value. This was the last item of the plan review. He will contact the electrical contractor and get back to me with value and I will red-line on plans.
|
Telephone call | | | 4/5/2007 | | DONE |
|
|
|
Call to Chris Anderson asking about electrical sheet resubmittals not correct with submittals of 3/30/07. Changes had been made to plans and he had not received copies. Will bring in copies for plans today.
|
Plan resubmittals received | | | 3/30/2007 | | DONE |
|
|
|
Received 1 letter of transmittal,1 review comments and 2 copys of sheets A2.01,A3.01,A4.01,M0.10,E3.0 taken to Dan S.
|
Routing - FIRE | 3/20/2007 | | 3/23/2007 | | PASS |
|
|
|
Attached IFC review comments to plans.
|
1st review completed | | | 3/23/2007 | | FAIL |
|
|
|
|
Plan resubmittals requested | | | 3/20/2007 | | DONE |
|
|
|
E-mail to David Rudeen for plan review corrections.
|
Routing - PLUMBING | 2/28/2007 | | 3/2/2007 | | PASS |
|
|
|
120 deg. max to public lavs.
|
Routing - PUBLIC WORKS | 2/27/2007 | | 2/28/2007 | | PASS |
|
|
|
|
Pending Assignment by MYS | 2/15/2007 | | 2/27/2007 | | DONE |
|
|
|
2/27/2007 12:09:03 MYS - activity updated through activity BLDA168 from case BLD07-00392.
|
Plans ACCEPTED BY PLAN TECH | | | 2/15/2007 | | |
|
|
|
|
Application received | | | 2/14/2007 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 2/14/2007 | | DONE |
|
|
|
|