Information based on query as of Wednesday, August 14, 2024.
Permit Information
Permit NumberBLD07-00515
StatusExpired
Name IDAHO MATERIAL HANDLING
Site Address 2929 S FEATHERLY WY
Project NameVICTORY PLAZA BLDG 2
Customer Number 
ePlanReviewNo
Description
(LOUIS AND COMPANY - VICTORY PLAZA BLDG 2 - RACKING) To install steel storage racks withn existing warehouse of Louis & Co. in accordance with attached engineering design and red-lined correction for approved concrete anchor, Hilti KB-TZ, approved for concrete (Hilti KB-III anchor red-lined through on plans is approved for masonry not concrete anchorage), see attached ESR-1917 for KB-TZ. High pile storage to comply with Ch. 23, 2003 IFC & NFPA for sprinklers. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Conference10/14/200910/14/200910/14/2009PDONE
DetailsMike Jordan
DOC - Permit Expired10/14/200910/14/200910/14/2009PPASS
DetailsMike Jordan
No inspections were called in and cold not get anyone to return my phone calls. Permit is expired.
BLD-Conference6/24/20086/24/20086/25/2008PPASS
DetailsMike Jordan
called and left message with Blaine at Idaho material handling. No call back.
BLD-Aging Inspection8/27/20078/27/20078/27/2007 NR
DetailsMike Jordan
Issue PAID IN FULL permit  5/18/2007 DONE
Telephone call  5/16/2007 DONE
called idaho material handling at ###-#### & will call me back
Routing - FIRE3/21/2007 3/26/2007 PASS
Attached IFC review comments to plans.
Plan assigned to (DRS)3/13/2007 3/26/2007 PASS
3/26/2007 11:50:22 DRS - activity updated through activity BLDA022 from case BLD07-00515.
1st review completed  3/26/2007 FAIL
Failed plan check.
Routing - PLAN CHECK3/26/2007 3/26/2007 PASS
Approved as noted on plans and attached plan review conditions.
PLANS/APPL TAKEN TO FRONT DESK  3/26/2007 PASS
Inspection Record Card- Bld  3/26/2007 DONE
CHANGE STATUS TO (RDY)  3/26/2007 DONE
Telephone call  3/26/2007 DONE
Called Blane permit ready and fee given ///dld
Routing - PLAN CHECK3/13/2007 3/21/2007 FAIL
Waiting for letter from engineer concerning concrete anchor, ESR 1917. Routing to fire code analyst for review.
Telephone call  3/21/2007 DONE
Phone call to Ben Riehl concerning the Hilti anchor assembly specified on plans. The ESR report indicates the anchor is approved for use in masonry but not concrete. We discussed ESR 1917, Hilti KB-TZ which is approved for concrete and does require special inspection. Ben is sending letter indicating change to plans and I will red-line plans and attach copy of his letter.
Plan resubmittals received  3/21/2007 DONE
Received letter from Ben Reihl concerning compliance with 2003 IBC for concrete anchors approved for such use as being ESR 1915, Hilti KB-TZ. The system originally listed, KB-III is listed for use in masonry only per report ESR 1385. I have red-lined plans to reference the Hilti KB-TZ, ESR 1917 as the applicable report and the need for special inspection per the report in accordancewith Sec. 1704 IBC.
Pending Assignment by MYS3/1/2007 3/13/2007 DONE
3/13/2007 11:39:13 MYS - activity updated through activity BLDA168 from case BLD07-00515.
Recd Pcfee & Taken To Pln CK  3/1/2007  
Plans ACCEPTED BY PLAN TECH  3/1/2007  
Application received  3/1/2007