Information based on query as of Sunday, August 18, 2024.
Permit Information
Permit NumberBLD07-00569
StatusFinaled
Name WILLIAM SMITH
Site Address 3214 E AMITY RD
Project NameCARVARA LLC
Customer Number 
ePlanReviewNo
Description
(CORVARA LLC - "VANILLA FINISH" REMODEL - NO TENANT DECLARED) **THIS BUILDING IS TO BE FIRE SPRINKLERED IN ACCORDANCE WITH NFPA 13 AS PART OF THIS PERMIT**. The addition of the sprinkler system will be used to downgrade construction type to Type VB. The sprinkler will be used to increase allowable area (by 2) and increase number of stories by one for future occupancies. To perform select demolition; to construct reinforced interior bearing footings; to construct interior bearing and non-bearing wood frame walls with 5/8" gypsum board on each side, nailed per plans, as shearwalls; provide hold down anchors per engineering & plans; install 11-7/8" TJI 210 @ 16" o.c. W/ 3/4" APA floor sheathing for a FUTURE (occupancy or access / egress not part of this permit) second office level above the first floor office based on engineering design; construct two fully accessible restrooms and a drinking fountain; install a service sink; an HVAC system to serve new office, electrical, plumbing and sprinkler system; accessible compliant interior doors and compliant hardware for all doors; two interior windows and interior finishes for office / restroom area. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
(F) Reprint permit  3/17/2010 DONE
DetailsTisha Gallop
Case Summary (BLD)  3/17/2010 DONE
DetailsTisha Gallop
Third Notice BLD12/22/200812/22/20083/9/2009 DONE
DetailsAlexandra L. DeYoung
Second Notice has not been responded to.
Second Notice BLD11/7/200811/7/200812/22/2008 DONE
DetailsCathy Brown
First Notice has not been responded to.
First Notice10/21/200810/21/200811/7/2008 DONE
DetailsJim Storey
BLD-Final10/21/200810/21/200810/21/2008PPASS
DetailsJim Storey
ron - please call 1/2 hr prior Phone #: ###-####
DOC - Permit Finaled10/21/200810/21/200810/21/2008PPASS
DetailsJim Storey
FIRE-Final Inspection10/20/200810/20/200810/20/2008PPASS
DetailsForrest France
Vanilla permit fire life safety inspection completed acceptable, contractor to remove manual thumbturn at the office area main entry/exit door prior to structural final as agreed.
BLD-Conference10/15/200810/16/200810/16/2008APASS
DetailsJim Storey
ron Note:please calll 1/2 hr prior to inspection Phone #: ###-####
BLD-Aging Inspection8/13/20088/13/20088/13/2008 PASS
DetailsJim Storey
william - please call 1/2 hr prior to inspection Phone #: ###-#### wip exstion ok for 180 days
BLD-Conference5/28/20085/29/20085/29/2008APASS
DetailsJim Storey
william - please call 1/2 hr prior to inspection Phone #: ###-#### wip exstion ok for 180 days
BLD-Aging Inspection1/24/20081/24/20081/25/2008 PASS
DetailsJim Storey
BLD-Aging Inspection7/17/20077/17/20077/18/2007 NR
DetailsJim Storey
Inspection Record Card- Bld  4/17/2007 DONE
Telephone call  4/17/2007 DONE
t/c w william smith at ###-#### - permit ready and fees given
Permit Ready to Issue  4/17/2007 DONE
Issue PAID IN FULL permit  4/17/2007 DONE
Case Summary (BLD)  4/16/2007  
Telephone call  4/16/2007 DONE
Call to TRW Arch. concerning cost of sprinkler system and intiial value to put in Certificate of Value. Bob Smith called me and said the value is $20,000.00 to repair the old system and add upgrades as required. Will red-line on CV and he will fax me a value.
Print Pending Permit.LaserJet4  4/16/2007  
Case Summary (BLD)  4/16/2007  
PLANS/APPL TAKEN TO FRONT DESK  4/16/2007 PASS
Approved as red-lined on plans and attached plan review conditions of all agencies.
Plan assigned to (DRS)3/16/2007 4/16/2007 PASS
4/16/2007 17:06:39 DRS - activity updated through activity BLDA022 from case BLD07-00569.
Routing - PLAN CHECK3/29/2007 4/16/2007 PASS
Plan resubmittals inserted into original plans. Plans & Certificate of Value red-lined and required. Plan review comments modified to reflect changes to plans by architect and engineer.
Plan resubmittals received  4/12/2007 DONE
Received 1 letter,1 comments,1plan review report1 structural calc, and 2 copys of sheets A0.1,A0.2,A1.1,A2.1,A3.1,A4.1,E2.1,S1.0,S2.0,S3.0,H2.1 taken to Dan S.
Telephone call  3/29/2007 DONE
Call from Tom williams concerning plan review requirements for project.
1st review completed  3/29/2007 FAIL
Failed plan check.
Routing - FIRE3/28/2007 3/29/2007 PASS
Attached IFC review comments to plans.
Plan resubmittals requested  3/28/2007 DONE
E-mailed plan review to TRW Architects for resubmittals required.
Routing - PLAN CHECK3/16/2007 3/28/2007 FAIL
Resubmittals required. Copy of plan review e-mailed to TRW architects. Routing to fire code analyst.
Routing - PUBLIC WORKS3/16/2007 3/16/2007 PASS
Application received  3/7/2007