Second Notice BLD | 1/9/2008 | 1/9/2008 | 1/10/2008 | | DONE |
Cathy Brown
|
|
|
First Notice has not been responded to.
|
First Notice | | 12/26/2007 | 1/9/2008 | | DONE |
|
|
|
|
Meeting | | | 12/28/2007 | | DONE |
|
|
|
Attended meeting with the Applicant, Jenifer, and George Slane the Building Official. Discussed the need for the Fire rated doors to be self closing per 2003 IBC 715.3.7 Fire doors shall be self-closing or automatic-closing per this code section. I stated the code requirement. The Applicant requested a code interpretation from the building official for the closet doors being required to be self-closing due to the failure to correctly close. The descision was made by the Building official to require the doors to have the self closing hardware even though they were not self-closing because of poor design. He stated the walls and ceiling of the closets were a One-hour assembly and would meet the intent of the fire rated assembly for the Entry. (SRZ)
|
Case Summary (BLD) | | | 12/28/2007 | | |
|
|
|
|
BLD-Final | 12/26/2007 | 12/26/2007 | 12/26/2007 | A | PASS |
Tom Arcoraci
|
|
|
Phone #: ###-#### Internet Inspection Request from: paul thornton
|
FIRE-Final Inspection | 12/26/2007 | 12/26/2007 | 12/26/2007 | A | PASS |
Troy Cobbley
|
|
|
All repairs corrected per Troys notes. KR
|
Permanent Occupancy | | | 12/26/2007 | | DONE |
|
|
|
|
BLD-Final | 12/21/2007 | 12/21/2007 | 12/21/2007 | P | CANC |
Mike Jordan
|
|
|
paul Phone #: ###-####
|
FIRE-Final Inspection | 12/20/2007 | 12/21/2007 | 12/21/2007 | A | FAIL |
Troy Cobbley
|
|
|
Out of the total 56 doors, of the 6 doors that I tried, only 2 closed/latched completely. One of the general contractors workers became ignorant with me so I stopped the inspection and left. I notified jennifer.
|
Code Occupancy Approval | 12/20/2007 | 12/20/2007 | 12/20/2007 | P | PASS |
Scott M.Brown
|
|
|
OK FOR FINAL
|
FIRE-Final Inspection | 12/19/2007 | 12/20/2007 | 12/20/2007 | A | FAIL |
Troy Cobbley
|
|
|
Provide self closers on all doors in the fire rated wall.
|
FIRE-Final Inspection | 12/14/2007 | 12/14/2007 | 12/14/2007 | P | FAIL |
Troy Cobbley
|
|
|
The project related fire sprinkler and fire alarm need to be finaled first. I let paul know that self closing doors are required. This was verified with Tim in plan review. A knox key box is being worked out as well.
|
BLD-Conference | 11/6/2007 | 11/6/2007 | 11/6/2007 | A | DONE |
Mike Jordan
|
|
|
i will be there until 8:30 Phone #: ###-#### Internet Inspection Request from: paul thornton
|
BLD-Conference | 10/30/2007 | 10/30/2007 | 10/30/2007 | A | DONE |
Mike Jordan
|
|
|
the installer will be there around 9:30 Phone #: ###-#### Internet Inspection Request from: paul thornton
|
BLD-Conference | 10/26/2007 | 10/26/2007 | 10/26/2007 | P | CANC |
Mike Jordan
|
|
|
paul Phone #: ###-####. Will reshedule.
|
BLD-Conference | 10/10/2007 | 10/10/2007 | 10/10/2007 | A | DONE |
Mike Jordan
|
|
|
the earlier the better Phone #: ###-#### Internet Inspection Request from: paul thornton
|
BLD-Wall cover | 9/28/2007 | 9/28/2007 | 9/28/2007 | P | PASS |
Mike Jordan
|
|
|
hat channel and 1st and 2nd layers of 5/8 type x at 1hr walls ans floor ceiling assemblies.
|
BLD-Energy code compliance | 9/26/2007 | 9/26/2007 | 9/26/2007 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Internet Inspection Request from: paul thornton. B vent has UL listed collar, all fire stop/block is complete. ok to cover.
|
BLD-Framing/Rough-in | 9/20/2007 | 9/21/2007 | 9/21/2007 | A | PART |
Mike Jordan
|
|
|
Phone #: ###-#### Internet Inspection Request from: paul thornton. pend. fire insp. Will check remaining issues on energy.
|
BLD-Framing/Rough-in | 9/19/2007 | 9/19/2007 | 9/19/2007 | A | PART |
Mike Jordan
|
|
|
Phone #: ###-#### Internet Inspection Request from: paul thornton. Complete firestop at sprinkler line penetrations, and floor ceiling penetrations, provide approved UL listed collar assembly for B vent at floor ceiling penetration. Complete lateral bracing, provide putty pads on elec. boxes were needed. repair tub drain penetration. pending fire ri insp. c/n posted.
|
BLD-Conference | 8/13/2007 | 8/13/2007 | 8/13/2007 | P | DONE |
Mike Jordan
|
|
|
paul Phone #: ###-####
|
BLD-Other | 8/6/2007 | 8/6/2007 | 8/6/2007 | P | PART |
Mike Jordan
|
|
|
paul Note: shear Phone #: ###-####. 5/8 type X, exterior portion of 1hr assembly ok.
|
BLD-Wall cover | 8/3/2007 | 8/3/2007 | 8/3/2007 | P | PART |
Mike Jordan
|
|
|
Exterior shear nailing and holdowns.
|
BLD-Conference | 8/2/2007 | 8/3/2007 | 8/3/2007 | A | CANC |
Mike Jordan
|
|
|
i want to sheetrock exterior to start siding Phone #: ###-#### Internet Inspection Request from: paul thornton. rescheduled for this afternoon.
|
Plan resubmittals received | | | 7/20/2007 | | |
|
|
|
Received two copies of pages A2.0, A2.1, A4.0; taken to Marlene
|
Plan resubmittals received | | | 7/18/2007 | | |
|
|
|
Revieved two copies of page A4.0; taken to Marlene S.
|
Plan resubmittals received | | | 7/17/2007 | | |
|
|
|
Per Marlene ok to taken in as resubs; Received two copies of pages A2.0, A2.1, A4.0, S2.0, S3.0; taken to Marlene S.
|
BLD-Footing | 7/13/2007 | 7/13/2007 | 7/13/2007 | P | PASS |
Jim Sly
|
|
|
paul Phone #: ###-#### Interior footings
|
BLD-Other | 6/26/2007 | 6/27/2007 | 6/27/2007 | A | PART |
Mike Jordan
|
|
|
a look at the blueboard Phone #: ###-#### Internet Inspection Request from: paul thornton. rigid foam insul. at interior side of stemwall.
|
BLD-Foundation | 6/22/2007 | 6/22/2007 | 6/22/2007 | P | PASS |
Mike Jordan
|
|
|
matt; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt
|
BLD-Footing | 6/21/2007 | 6/21/2007 | 6/21/2007 | P | PASS |
Mike Jordan
|
|
|
matt; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt
|
Issue PAID IN FULL permit | | | 6/12/2007 | | DONE |
|
|
|
|
Print Occupancy Form | | | 6/8/2007 | | |
|
|
|
|
Permit Ready to Issue | | | 6/8/2007 | | |
|
|
|
|
Plan assigned to (M_P) | 3/14/2007 | 3/14/2007 | 6/7/2007 | | PASS |
|
|
|
6/7/2007 16:41:00 MYS - activity updated through activity BLDA022 from case BLD07-00599.
|
Routing - PLAN CHECK | 6/4/2007 | | 6/7/2007 | | PASS |
|
|
|
Waiting for parcel numbers. Sub recorded on 6/4/2007.
Received parcel number on 6/7/2007 and prepared for issuance.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 6/7/2007 | | DONE |
|
|
|
|
Telephone call | | | 6/5/2007 | | DONE |
|
|
|
Talked to Steve White. Need Ada County Parcel Worksheet w/new parcel numbers so I can take to permit desk for issuance.
|
Routing - PUBLIC WORKS | 6/4/2007 | | 6/4/2007 | | PASS |
|
|
|
|
Routing PW Solid Waste | 5/24/2007 | | 5/31/2007 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS | 5/24/2007 | | 5/24/2007 | | FAIL |
|
|
|
See solid waste notes.
|
Routing - PLAN CHECK | 5/11/2007 | | 5/24/2007 | | PEND |
|
|
|
Waiting for others to approve prior to issuing permit.
|
Routing - PLAN CHECK | 5/24/2007 | | 5/24/2007 | | |
|
|
|
Routing to P.W.
|
Routing - PUBLIC WORKS | 3/14/2007 | | 5/24/2007 | | FAIL |
|
|
|
Since trash truck turn-around is a basketball court, revised plans must show rolling gate or similar device to protect pedestrians while truck is backing in. Pamela Williams ###-####
|
Plan resubmittals received | | | 5/18/2007 | | |
|
|
|
received letter from houston bugatsch arch(5) pages & 1 letter from houston bugatsch arch & (2) sets of plans with each sheet A1.O, A1.1, A2.O, A2.1, A4.O, & E1.1--plans taken to Mike Phillips
|
Routing - PUBLIC WORKS | 5/9/2007 | | 5/11/2007 | | FAIL |
|
|
|
|
Routing - PLAN CHECK | 4/20/2007 | | 5/9/2007 | | FAIL |
|
|
|
Second review failed, called architect and requested additional details to be submitted to reflect a rated assembly for the corridor/stairs.
|
Plan resubmittals received | | | 5/9/2007 | | |
|
|
|
Received 1 response letter from Houston-Bugatsch (5 pgs), 1 copy of plan review comments letter (13 pgs), 2 copies of Engineering Calcs, 2 copies of sheets A1.0, L-1, C-5, S1.0, S2.0, S3.0, A2.0, A2.1, A3.0, A3.1, A4.0, A5.0, A6.0, E.01, W1.1, M2.1, M3.0 and taken to Mike Phillips
|
Routing - PLANNING | 4/20/2007 | | 4/20/2007 | | PASS |
|
|
|
(AW delegated plans today b/c SAR out sick)
Bld07-599, 602, 606, 607, 608, 609, 610, 611..
Mike Phillips rtd. to planning 4/16 b/c the computer indicated pass but the plans did not have a pass signature.
|
Routing - PLAN CHECK | 4/10/2007 | | 4/16/2007 | | |
|
|
|
Routing to Planning
|
Routing - PLANNING | 4/13/2007 | | 4/13/2007 | | PASS |
|
|
|
|
Routing - FIRE | 4/5/2007 | | 4/10/2007 | | PASS |
|
|
|
Attached review comments to plans.
|
1st review completed | | | 4/10/2007 | | FAIL |
|
|
|
|
Routing - PLAN CHECK | 4/3/2007 | | 4/5/2007 | | FAIL |
|
|
|
Sent correction report to the architect, requesting additional information to be submitted for further review prior to issuing permit.
|
Routing - PLANNING | 3/30/2007 | | 4/3/2007 | | FAIL |
|
|
|
CUP05-00056- Susan Riggs called applicant waiting for cross access agreement
Approved per DRH07-00082- Greg Johnson
|
Routing - PLUMBING | 3/20/2007 | | 3/30/2007 | | PASS |
|
|
|
dcva required on the service to the building in the crawlspace near access. thermol expantion protection required.
|
Routing - Erosion and Sediment | 3/19/2007 | | 3/20/2007 | | PASS |
|
|
|
ESC plan approved with attached conditions. Refer to ESC07-00288 as master ESC plan for proje
|
Routing - PLANNING Land Div | 3/14/2007 | | 3/14/2007 | | PASS |
|
|
|
|
Plan routing begun/NEW & ADDTN | | | 3/14/2007 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 3/13/2007 | | DONE |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 3/13/2007 | | |
|
|
|
|
Application received | | | 3/9/2007 | | |
|
|
|
|