Information based on query as of Tuesday, July 16, 2024.
Permit Information
Permit NumberBLD07-00690
StatusFinaled
Name ST LUKES REG MED CNTR
Site Address 510 N 2ND ST
Project NameIDAHO ELKS REHAB OFFICE
Customer Number26-189
ePlanReviewNo
Description
St Lukes Reg Med Cntr (MOUNTAIN STATE UROLOGY - IDAHO ELK REHAB OFFICE BLDG - 1ST FLR) This building is fully sprinklered. To build-out a shell space of 4,600 sq. ft. for use as medical office, exam & procedures services facility for 'Mountain States Urology'. Work includes construction of non-combustible walls to create offices, procedure rooms, exam rooms, nurse stations, reception & waiting, four fully accessible restrooms and support areas. To install a suspended ceiling grid system; electrical, plumbing, mechanical, sprinkler and alarm systems; interior finishes, millwork, doors and hardware. All per notes on plans and all attached plan review conditions of all reviewing agencies, all part of the approved plans. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  3/11/2014 DONE
Third Notice BLD12/11/200712/11/20071/11/2008 DONE
DetailsCathy Brown
Second Notice has not been responded to.
Second Notice BLD11/13/200711/13/200712/11/2007 DONE
First Notice has not been responded to.
First Notice 10/12/200711/13/2007 DONE
Permanent Occupancy  10/12/2007  
BLD-Final10/8/200710/9/200710/9/2007APASS
DetailsDave Hannah
rock Phone #: ###-#### ok for perm occ
BLD-Final10/2/200710/3/200710/3/2007AFAIL
DetailsDave Hannah
ROCK Phone #: ###-#### needs ADA signage and ceiling grid spreader bars ect
FIRE-Final Inspection10/1/200710/2/200710/2/2007APASS
DetailsForrest France
Fire life safety is satisfactory, inspection passed.
BLD-Framing/Rough-in6/5/20076/6/20076/6/2007APASS
DetailsDave Hannah
Rock; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt
Print Occupancy Form  5/2/2007 DONE
CHANGE STATUS TO (RDY)  5/2/2007 DONE
Telephone call  5/2/2007  
Called Curtis permit ready
Issue & PRINT to be Invoiced  5/2/2007 DONE
Telephone call  5/1/2007 DONE
John Maulin CSHQA to discuss proceedure for or policy used by the Building Official to determine code interpretations.
PLANS/APPL TAKEN TO FRONT DESK  5/1/2007 PASS
Plan assigned to (DRS)3/29/2007 5/1/2007 PASS
5/1/2007 16:23:06 DRS - activity updated through activity BLDA022 from case BLD07-00690.
Routing - PLAN CHECK4/24/2007 5/1/2007 PASS
Approved as noted and attached. To permit desk to issue.
Plan Reviewer's activity  5/1/2007 DONE
Interpretation by George slane, Building Official, concerning tactile signs and accessibility requirements for exam and proceedure room millwork with sinks. TACTILE EXIT SIGNS ARE REQUIRED AT EXIT DISCHARGE EVEN IF A LIGHTED EXIT SIGN IS NOT REQUIRED PER EXCEPTIONS OF 1011.1 IBC. INTERPRETATIONS THAT THE MILLWORK AND SINK IN THE EXAM AND PROCEEDURE ROOMS ARE EMPLOYEE ORK AREAS AND DO NOT NEED TO COMPLY FOR ACCESSIBLITY.
Telephone call  4/30/2007 DONE
Concerning e-mails from Kermit Robinson, ICC Technical Staff, sent to John Maulin & Teresa Preston. Sent copy to George slane for interpretation and copy to Kim Paarlberg, ICC Technical Staff, for her opinion.
Plan Reviewer's activity  4/30/2007 DONE
E-mail from Kimberly Paarlberg, ICC Tech Staff saying she agreed with Kermit Robinsons opinion of counter and sinks in exam & proceedure rooms being employee work areas and not requiring accessiblity. The rooms need to be on an accessible route so they can be entered and exited which these are.
Plan resubmittals requested  4/24/2007 DONE
Faxed copy of remaining code items needing to be corrected to Teresa Preston. Followed up by e-mail telling her a fax was sent and to let me know if she did not receive it.
Routing - PLAN CHECK4/12/2007 4/24/2007 FAIL
Resubmittals inserted into original plans. Accessibility items for sink depth, clear floor space at sinks and tactile exit sign were incorrectly addressed. Faxed copy of remaining items to Teresa with follow up notification by e-mail.
Plan resubmittals received  4/23/2007  
Received 1 cover transmittal, 1 response to plan reveiw comments, 2 pages (1set) of countertop lavatory specs, 1 copy of plan reiew report, 2 copies of sheets A0.2, A2.1, A5.1, A5.4, A5.5 and taken to Dan Stuart
Routing - FIRE4/9/2007 4/12/2007 PASS
Attached IFC review comments to plans.
1st review completed  4/12/2007 FAIL
Routing - PLAN CHECK4/2/2007 4/9/2007 FAIL
Resubmittals required. Copy of review e-mailed to architect. Routing to fire code analyst.
Plan resubmittals requested  4/9/2007 DONE
Copy of plan review to Teresa Preston, CSHQA.
Routing - PLUMBING3/30/2007 4/2/2007 PASS
additional cross connection protection may be required. notes 1&2 page P-2.1- pipe hub drain and R.P. to cabinet under S-1.
Routing - PUBLIC WORKS3/29/2007 3/30/2007 PASS
Routing - Addressing3/29/2007 3/29/2007 PASS
Pending Assignment by MYS3/19/2007 3/29/2007 DONE
3/29/2007 11:16:39 MYS - activity updated through activity BLDA168 from case BLD07-00690.
Plans ACCEPTED BY PLAN TECH  3/20/2007  
Application received  3/19/2007