Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD07-00957
StatusFinaled
Name STRIKER CONSTRUCTION
Site Address 509 W MAIN ST
Project NameMack & Charlies
Customer Number 
ePlanReviewNo
Description
(MACK & CHARLIES) To remodel a 3,450 sq.ft. space previously occupied by a restaurant (Pacific Subs) into a bar. To perform selective interior demolition of non-bearing systems; open up an 8ft. portion of the existing 2-hour frame wall and install a 90 minute roll down fire door between this space (509) and 507 W. Main Street (Hangar Bar); construct two fully accessible restrooms with three toilet fixtures each and 2 lavs each; add some new light fixture's, millwork and interior finishes per approved plans. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice BLD12/11/200712/11/20071/18/2008 DONE
DetailsCathy Brown
Second Notice has not been responded to.
Second Notice BLD11/13/200711/13/200712/11/2007 DONE
First Notice has not been responded to.
First Notice 10/17/200711/13/2007 DONE
BLD-Conference10/17/200710/17/200710/17/2007PCANC
DetailsTony Young
Permanent Occupancy  10/17/2007 DONE
BLD-Final10/16/200710/16/200710/16/2007PPASS
DetailsTony Young
ryan Phone #: ###-####
ok for perm c of o
BLD-Final10/11/200710/12/200710/12/2007APART
DetailsDave Hannah
michael Phone #: ###-#### ok for temp occ needs to finish restrooms and end of ramp
Temporary Occupancy UNPAID FEE  10/12/2007  
Temporary Occupancy UNPAID FEE  10/12/2007  
Temporary Occupancy UNPAID FEE  10/12/2007  
Temporary Occupancy UNPAID FEE  10/12/2007  
FIRE-Final Inspection10/10/200710/11/200710/11/2007APASS
DetailsForrest France
tested rollup fire door, completed fire life safety.
FIRE-Final Inspection10/9/200710/10/200710/10/2007AFAIL
DetailsForrest France
Need to Install 1 new 2A10BC extinguisher,Change door handle between main area and hallway to restrooms, Need to test fire rated rollup door/ will have door company onsite for testing.
BLD-Framing/Rough-in10/9/200710/9/200710/9/2007PCANC
DetailsDave Hannah
michael - overhead grid Phone #: ###-####its ext grid ok per old code
BLD-Framing/Rough-in9/12/20079/12/20079/12/2007PPART
DetailsDave Hannah
michael Note: cover Phone #: ###-#### ok to cover walls
(F) Reprint permit  8/3/2007  
Telephone call  6/28/2007 DONE
Called Kirk @ Modus and left voice message that permit is ready, fees and that we need GC info & RP info///6/28/07 @ 9:42am BAS
Issue PAID IN FULL permit  6/28/2007 DONE
Waiting for Cert. of Value  6/27/2007  
Per Dan Stuart waiting for revised Cert of value///6/27/07 BAS
Plan resubmittals received  6/27/2007  
received letter from modus architecture & cert of value--paperwork taken to Dan Stuart
Received Certificate of Value  6/27/2007 DONE
Received revised Cert of Value, scanned and attached to documents, adjusted valuation///6/27/07 BAS
Permit Ready to Issue  6/27/2007 DONE
Print Occupancy Form  6/27/2007 DONE
Routing - PLAN CHECK6/22/2007 6/26/2007 PASS
Resubmittals for 2nd review received and inserted into plans. No further resubmittals required.
PLANS/APPL TAKEN TO FRONT DESK  6/26/2007 PASS
Plan assigned to (DRS)4/19/2007 6/26/2007 PASS
6/26/2007 13:34:50 DRS - activity updated through activity BLDA022 from case BLD07-00957.
Routing - PLUMBING6/26/2007 6/26/2007 PASS
Plans still required. Copy of review to architect. Will review for approval of plans in the field. incomplete plumbing plans. provide resubmittals at rough in.
Plan resubmittals received  6/22/2007  
Received transmittal, plan review comments from architect, specs for overhead coiling fire rated door, specs for walk-in cooler, and three copies of pages A0.0, A2.0, A3.0; taken to Dan Stuart
Plan Reviewer's activity  6/20/2007 DONE
Call from Justin at Modus architects inquiring about review progess for project. I told him additional resubmittals were required and that I had e-mailed a copy of report to Kirk Morris, architect of record, on 6/13/07. Justin said Kirk has been having problems with e-mail and ask if I would e-mail copy to him at jlilya@gomodus.com. I did.
Routing - PLANNING6/14/2007 6/15/2007 PASS
Allowed use, no min. parking requirements.
Routing - Erosion and Sediment6/13/2007 6/14/2007 PASS
ESC waiver request approved with attached conditions.
Plan resubmittals requested  6/13/2007 DONE
Copy of second plan review and items still needing to be addressed or clarified sent to architect.
Routing - PLAN CHECK5/22/2007 6/13/2007 FAIL
Resubmittals of 6/12/07 inserted into original plans. Plans reviewed for code compliance. several items were not addressed or incorrectly addressed and require additional resubmittals from architect. Copy of modified plan review e-mailed to architect for response. Routing plans to ESC, Planning & Plumbing for review.
Plan resubmittals received  6/12/2007  
Received 1 review comments,1 waiver request for esc1 esc application,1 fire door,1 gas tender, 1 ventilation, and 3 copys of sheets A0.0,A1.0,A2.0,A2.1,A2.2,A3.0,A4.0,A5.0,A6.0 taken to Dan S.
1st review completed  5/22/2007 FAIL
Routing - FIRE5/18/2007 5/22/2007 PASS
Attached review comments to plans.
Routing - PLAN CHECK4/24/2007 5/18/2007 FAIL
Resubmittals required. Copy of plan review items to architect by e-mail.
Plan resubmittals requested  5/18/2007 DONE
E-mail to Kirk Morris - kmorris@gomodus.com with attached plan review.
Routing - PLUMBING4/20/2007 4/24/2007 FAIL
provide plumbing plans
Routing - PUBLIC WORKS4/19/2007 4/20/2007 PASS
Routing - Addressing4/19/2007 4/19/2007 PASS
Pending Assignment by MYS4/18/2007 4/19/2007 DONE
4/19/2007 13:03:41 MYS - activity updated through activity BLDA168 from case BLD07-00957.
Plans ACCEPTED BY PLAN TECH  4/17/2007  
Need G.C. # , did not see any mechanical / but have a value of 4,000 ///dld
Recd Pcfee & Taken To Pln CK  4/17/2007  
Application received  4/17/2007