Permit Information
Permit NumberBLD07-01069
StatusFinaled
Name GUNTHER MANAGEMENT
Site Address 8030 W EMERALD ST
Project Name 
Customer Number 
ePlanReviewNo
Description
**(United Auto Credit Corp)**(Suite #155) To remodel an existing 2,100 sq ft office space for a new office tenant per approved plans. Work to include, construction of new nonbearing interior partitions to create individual office spaces, relocate existing lighting, repair and replace existing ceiling tiles, replace floor finishes and miscellaneous related interior finishes. This building is fully fire sprinkled ANY ALTERATIONS OR MODIFICATIONS to the sprinkler system WILL REQUIRE A SEPARATE PERMIT, and shall be installed and maintained per NFPA #13 as regulated by the fire department. RmH
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice BLD7/18/20077/18/20077/20/2007 DONE
Second Notice has not been responded to.
Second Notice BLD6/21/20076/21/20077/18/2007 DONE
First Notice has not been responded to.
First Notice 5/30/20076/21/2007 DONE
BLD-Final5/29/20075/30/20075/30/2007APASS
DetailsMike Jordan
sergey - please call for access ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith. ok for perm occ.
Permanent Occupancy 5/30/20075/30/2007 DONE
Details
Permanent occupancy UNPAID FEE  5/30/2007 DONE
Perm. Occ. Cert. # 11640 issued 5-30-07 to United Auto Credit Corp.
FIRE-Final Inspection5/29/20075/29/20075/29/2007PPASS
DetailsTroy Cobbley
life safety passed
Code Occupancy Approval5/15/20075/15/20075/15/2007PCANC
DetailsDena Gambrel
BLD-Framing/Rough-in5/3/20075/4/20075/4/2007APASS
DetailsMike Jordan
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Noted to contractor that a mech. permit is required. Interior non load bearing walls ok.
BLD-Energy code compliance5/2/20075/3/20075/3/2007ANR
DetailsMike Jordan
Mike framing as well; Phone #: ###-#### Internet Inspection Request from: Andrea Whiteman. Needs elec ri insp, Also needs to pull mech permit.
FIRE-Final Inspection5/2/20075/3/20075/3/2007AFAIL
DetailsTroy Cobbley
The sprinkler pendants are overspaced. This work will require permits. Provide updated tag for the fire extinguisher. Provide the approved door hardware as per the approved drawings. Remove the thumbturn from the main exit and provide indicator. Keyed lock is ok for the interior
Pending Assignment by MYS4/30/2007 5/2/2007 DONE
5/2/2007 09:56:39 RMH - activity updated through activity BLDA175 from case BLD07-01069.
Plan assigned to (R_H)5/2/2007 5/2/2007 PASS
5/2/2007 10:06:08 RMH - activity updated through activity BLDA022 from case BLD07-01069.
Routing - PLAN CHECK4/28/2007 5/2/2007 PASS
Routing - FIRE5/2/2007 5/2/2007 PASS
Case Summary (BLD)  5/2/2007 DONE
1st review completed  5/2/2007  
PLANS/APPL TAKEN TO FRONT DESK  5/2/2007 DONE
Print Occupancy Form  5/2/2007 DONE
CHANGE STATUS TO (RDY)  5/2/2007 DONE
Telephone call  5/2/2007  
Called Sergey Permit ready and fee given / they will be the G.C. ///DLD
Issue PAID IN FULL permit  5/2/2007 DONE
Plans ACCEPTED BY PLAN TECH  4/30/2007  
Application received  4/27/2007  
Recd Pcfee & Taken To Pln CK  4/27/2007