Second Notice BLD | 7/5/2007 | 7/5/2007 | 7/10/2007 | | DONE |
|
|
|
First Notice has not been responded to.
|
First Notice | | 6/20/2007 | 7/5/2007 | | DONE |
|
|
|
|
Permanent occupancy UNPAID FEE | | | 6/20/2007 | | DONE |
|
|
|
Perm. Occ. Cert. # 11671 issued 6-20-07 to Engineering Science Construction.
|
BLD-Final | 6/19/2007 | 6/19/2007 | 6/19/2007 | P | PASS |
Dave Hannah
|
|
|
paul; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang ok for perm occ
|
FIRE-Final Inspection | 6/19/2007 | 6/19/2007 | 6/19/2007 | P | PASS |
Forrest France
|
|
|
Required corrections verified, fire life safety passed.
|
Permanent Occupancy | | 6/19/2007 | 6/19/2007 | | DONE |
|
|
|
|
BLD-Final | 6/8/2007 | 6/8/2007 | 6/8/2007 | P | CANC |
Dave Hannah
|
|
|
paul; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt
|
FIRE-Final Inspection | 6/8/2007 | 6/8/2007 | 6/8/2007 | P | FAIL |
Forrest France
|
|
|
Need to provide approved hardware at three locations, a fire sprinkler permit will be required to make necessary corrections caused by building modifications, also noted two fire alarm notification devices have been relocated without a permit and will need to be tested and inspected with the proper permit prior to fire life safety final, also need to repair balasts on two emergency lights.
|
BLD-Framing/Rough-in | 5/24/2007 | 5/24/2007 | 5/25/2007 | P | PART |
Dave Hannah
|
|
|
paul note: ceiling; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to cover ceiling grid
|
BLD-Framing/Rough-in | 5/21/2007 | 5/21/2007 | 5/21/2007 | P | FAIL |
Dave Hannah
|
|
|
paul; Phone #: ###-#### Internet Inspection Request from: Delphine Kavanaugh needs to wire up lights and mec fixtures
|
Issue PAID IN FULL permit | | | 5/9/2007 | | DONE |
|
|
|
|
(F) Reprint permit | | | 5/9/2007 | | |
|
|
|
|
Plan assigned to (R_H) | 4/30/2007 | 4/30/2007 | 5/7/2007 | | PASS |
|
|
|
5/7/2007 13:31:05 RMH - activity updated through activity BLDA022 from case BLD07-01071.
|
Routing - PLAN CHECK | 5/7/2007 | | 5/7/2007 | | PASS |
|
|
|
|
Routing - FIRE | 5/7/2007 | | 5/7/2007 | | PASS |
|
|
|
Minor remodel / field verify
|
Case Summary (BLD) | | | 5/7/2007 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 5/7/2007 | | DONE |
|
|
|
|
1st review completed | | | 5/7/2007 | | |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 5/7/2007 | | DONE |
|
|
|
|
Print Occupancy Form | | | 5/7/2007 | | DONE |
|
|
|
|
Telephone call | | | 5/7/2007 | | DONE |
|
|
|
left vm for steve christenson at ###-#### - permit ready and fees given - also need gc name and rce#
|
Permit Ready to Issue | | | 5/7/2007 | | DONE |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 4/30/2007 | | |
|
|
|
|
Pending Assignment by MYS | 4/27/2007 | | 4/30/2007 | | DONE |
|
|
|
4/30/2007 10:01:20 LEG - activity updated through activity BLDA175 from case BLD07-01071.
|
Recd Pcfee & Taken To Pln CK | | | 4/27/2007 | | DONE |
|
|
|
|
Application received | | | 4/27/2007 | | |
|
|
|
|