Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD07-01138
StatusFinaled
Name ROBNETT CONSTRUCTION INC
Site Address 2906 S FEATHERLY WAY
Project NameMagic Valley Truck Brokers
Customer Number 
ePlanReviewNo
Description
Magic Valley Trucking Brokers - To construct a new 8,620 square foot, one story, masonry and wood framed office and storage shell building and related site improvements. This is a shell permit only and no occupancy is allowed under this permit. Separate tenant improvement permits will be required to finish this building for occupancy. The construction type was changed to IIIB to comply with minimum fire flow requirements. All construction per the approved plans and attached comment list. JCM
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/6/200712/6/200712/7/2007PPASS
DetailsMike Jordan
ok for perm occ.
Letter of compliance  12/7/2007 DONE
Cert. of Compliance issued 12-7-07
BLD-Final11/28/200711/28/200711/28/2007PPART
DetailsMike Jordan
Gary Phone #: ###-####. Will issue leteer of compliance for shell once final aff.letter from special insp. agency is received and a tempered window is installed at breakroom.
Code Occupancy Approval11/28/200711/28/200711/28/2007PPASS
DetailsScott M.Brown
OK FOR FINAL
BLD-Grading Inspection11/27/200711/28/200711/28/2007ADEFR
DetailsJim Sly
Phone #: ###-#### Internet Inspection Request from: Gary Band
Shoud have called for P/W.
BLD-Final11/26/200711/27/200711/27/2007PNR
DetailsMike Jordan
Also need to schedule same inspection for the t.i., which is permit # BLDO7-01151 Phone #: ###-#### Internet Inspection Request from: Gary Band
FIRE-Final Inspection11/26/200711/27/200711/27/2007PPASS
DetailsTroy Cobbley
life safety passed
BLD-Energy code compliance11/1/200711/2/200711/2/2007APASS
DetailsMike Jordan
gary Phone #: ###-####
BLD-Energy code compliance10/31/200710/31/200710/31/2007PPART
DetailsMike Jordan
Stiil needs to complete lateral bracing. insul ok.
BLD-Energy code compliance10/30/200710/31/200710/31/2007ACANC
DetailsMike Jordan
gary Phone #: ###-####
BLD-Framing/Rough-in10/29/200710/30/200710/30/2007APART
DetailsMike Jordan
gary Phone #: ###-####. Needs to complete lateral bracing, and repair cut studs. ok to insul, Nees to call in ti for framing.
BLD-Other10/22/200710/23/200710/23/2007PPASS
DetailsMike Jordan
jerry Note: nail roofing late as possible Phone #: ###-####. Remainder of nailing for roof diaphragm.
BLD-Other10/17/200710/18/200710/18/2007APART
DetailsMike Jordan
gary - roof nailing inspection Phone #: ###-####. Nailing on roof diaphragm.
BLD-Framing/Rough-in9/28/200710/1/200710/1/2007ACANC
DetailsMike Jordan
gary - continuous wall inspection Phone #: ###-####. Canc. by contractor via phone.
BLD-Other9/25/20079/26/20079/26/2007APASS
DetailsMike Jordan
gary - continuous wall Phone #: ###-####
Plan Reviewer's activity  9/26/2007 DONE
Debbie with magic valley trucking called in about changing roof pitch from 3.5 / 12 to a 4 / 12. After checking with her original reviewer John Menard and DRH supervisor Sarah Schaffer. They both were ok with the change. Requiring only resubmitted sheets showing new roof pitch. On sept. 26, 2007 revised A2.0, A2.1, A2.2, and A2.3 sheets were submitted and incerted into shell plans.
BLD-Framing/Rough-in9/19/20079/20/20079/20/2007PPART
DetailsMike Jordan
gary Phone #: ###-####.. CMU wall, sw end top of wall, wip, installing verts.
BLD-Framing/Rough-in9/14/20079/17/20079/17/2007ADEFR
DetailsMike Jordan
gary Phone #: ###-####. Special insp.
BLD-Wall cover8/7/20078/8/20078/8/2007PCANC
DetailsMike Jordan
Paul ; Phone #: ###-#### Internet Inspection Request from: Darla Downs
BLD-Wall cover8/7/20078/8/20078/8/2007APART
DetailsMike Jordan
paul Note: wall insp Phone #: ###-####. wip. reviewed approved plans. Special insp on conc. and rebar.
BLD-Footing8/6/20078/7/20078/7/2007APART
DetailsMike Jordan
paul - pour at 10:00 Phone #: ###-####. Approved plans not on job site. Contacted contractor, boted that footing will have special insp. Noted to contractor to have approved plans on site for stemwall placement.
(F) Reprint permit  7/20/2007  
Issue PAID IN FULL permit  7/19/2007 DONE
Print Occupancy Form  7/18/2007 DONE
Telephone call  7/18/2007 DONE
left vm for dion zimmerman at ###-#### - permit ready and fees given - also need receipt for ACHD
Permit Ready to Issue  7/18/2007 DONE
Routing - PUBLIC WORKS7/16/2007 7/17/2007 PASS
Routing PW Sewer Rating7/17/2007 7/17/2007 PASS
Routing PW Solid Waste7/17/2007 7/17/2007 PASS
Routing - FIRE7/17/2007 7/17/2007 PASS
Attached updated review comments to plans.
Routing - PLAN CHECK7/17/2007 7/17/2007 PASS
PLANS/APPL TAKEN TO FRONT DESK  7/17/2007 DONE
Plan assigned to (JCM)5/7/2007 7/17/2007 PASS
7/17/2007 15:25:48 JCM - activity updated through activity BLDA022 from case BLD07-01138.
Routing - PLAN CHECK6/12/2007 7/16/2007 PASS
Reviewed and approved resubmittals.
Plan resubmittals received  7/13/2007  
received 3 copys of sheets AC2.0 taken to John M.
Routing Off Site - STRUCTURAL6/26/2007 7/2/2007 PASS
Called Action Courier for pick up on 6/26/07 @ 11:53am BAS - REceived letter from consultlng structural engineer approving resubmittals.
Plan resubmittals received  6/22/2007  
Received 1 copy of response comments from GJZ Architecture (2 pgs), 1 copy of flow Info from United Water (2pgs), 1 copy of plot plan, 1 copy of response comments from Holladay Engineering Co (2 pgs), 1 set of Addendum to structural calculations (21 pgs) 3 copies of sheets G-1.0, L-1.0, S-1.0, S-1.2, A-1.0, A-2.1, A-2.2, A-2.3, A-3.0, A-4.1 and taken to John Menard///6/22/07 BAS
1st review completed  6/12/2007 FAIL
Routing - FIRE6/8/2007 6/12/2007 FAIL
Faxed and emailed fire code resubmittal items to archteict.
Routing - PLAN CHECK5/21/2007 6/8/2007 FAIL
Plan resubmittals requested  6/8/2007 DONE
E-mailed the architect a copy of the plan review requesting revisions.
Plan resubmittals requested  5/22/2007 DONE
Faxed the architect a copy of the structural plan review requesting revisions.
Routing Off Site - STRUCTURAL5/8/2007 5/22/2007 FAIL
Called Action Couriers for pick up - Received comment list from the consulting structural engineer requesting revisions.
Routing - PLANNING5/16/2007 5/21/2007 PASS
Greg J.
Routing - PLUMBING5/10/2007 5/16/2007 PASS
Routing - Erosion and Sediment5/10/2007 5/10/2007 PASS
ESC plan approved with attached conditions.
Routing - PUBLIC WORKS5/8/2007 5/10/2007 FAIL
Routing PW Sewer Rating5/9/2007 5/10/2007 PASS
FEES ASSESSED ON TENANT IMPROVEMENT PLANS
Routing PW Solid Waste5/9/2007 5/10/2007 FAIL
The minimum interior enclosure dimensions are 11' wide x 8' deep with gates that open 180 degrees along the 11' dimension. These are requirements for automated trash service. Need revised pg. C2.0 showing enclosure with proper dimensions, plus a detail of trash enclosure construction.
Routing PW Sewer Design5/9/2007 5/9/2007 PASS
Routing PW Street Lights5/9/2007 5/9/2007 PASS
Routing PW Drainage5/9/2007 5/9/2007 PASS
Routing - PLANNING Land Div5/8/2007 5/8/2007 PASS
Application received  5/7/2007  
Plans ACCEPTED BY PLAN TECH  5/7/2007  
Plan routing begun/NEW & ADDTN  5/7/2007