Case Summary (BLD) | | | 3/12/2012 | | |
|
|
|
|
Second Notice BLD | 11/13/2007 | 11/13/2007 | 12/6/2007 | | DONE |
|
|
|
First Notice has not been responded to.
|
Second Notice BLD | 11/13/2007 | 11/13/2007 | 12/6/2007 | | DONE |
|
|
|
First Notice has not been responded to.
|
Third Notice BLD | 10/30/2007 | 10/30/2007 | 12/6/2007 | | DONE |
|
|
|
Second Notice has not been responded to.
|
First Notice | | 10/22/2007 | 11/13/2007 | | DONE |
|
|
|
|
First Notice | | 10/22/2007 | 11/13/2007 | | DONE |
|
|
|
|
Second Notice BLD | 10/1/2007 | 10/1/2007 | 10/30/2007 | | DONE |
|
|
|
First Notice has not been responded to.
|
Permanent Occupancy UNPAID FEE | | | 10/22/2007 | | DONE |
|
|
|
|
First Notice | | 9/11/2007 | 10/1/2007 | | DONE |
|
|
|
|
BLD-Final | 9/10/2007 | 9/10/2007 | 9/10/2007 | P | PASS |
Jim Sly
|
|
|
###-#### - dennis OK for Perm Occ.
|
Code Occupancy Approval | 9/7/2007 | 9/7/2007 | 9/7/2007 | P | PASS |
Carol Montgomery
|
|
|
|
Code Occupancy Approval Temp | 8/24/2007 | 8/24/2007 | 8/29/2007 | P | FAIL |
Carol Montgomery
|
|
|
Signed on Temporary - Landscaping; fencing; stiping and H/C sign. Failed Final - signed on Temp. Bond posted ($16,000.+)
|
BLD-Final | 8/23/2007 | 8/24/2007 | 8/24/2007 | P | PART |
Jim Sly
|
|
|
dennis Phone #: ###-#### Need Plumbing perm....... C/N Need Temp glass at ramp areas......windows covered with ply.......OK for Temp Code Enforce bonded (landsc)
|
FIRE-Final Inspection | 8/23/2007 | 8/24/2007 | 8/24/2007 | A | PASS |
Troy Cobbley
|
|
|
Life safety passed.
|
FIRE-Final Inspection | 8/23/2007 | 8/23/2007 | 8/24/2007 | P | FAIL |
Troy Cobbley
|
|
|
Provide the two missing smoke detectors and provide approved hardware on the pocket door.
|
Temporary Occupancy UNPAID FEE | | | 8/24/2007 | | DONE |
|
|
|
|
BLD-Framing/Rough-in | 8/2/2007 | 8/2/2007 | 8/2/2007 | P | PASS |
Jim Sly
|
|
|
curtis - partial - early afternoon please Phone #: ###-####
|
Telephone call | | | 7/27/2007 | | DONE |
|
|
|
Call from Dennis Paul, contractor, proposing lowering only the "L" shape portion of the existing kitchen counter and installing a new accessible sink with drinking fountain in this portion to meet reach range for controls, a new outlet within reach ranges. He will discuss with architect and provide drawings if changes are to be made.
|
Override - Parcel Holds | | | 7/17/2007 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 7/17/2007 | | DONE |
|
|
|
|
Telephone call | | | 7/9/2007 | | DONE |
|
|
|
Called Dennis Paul - ACHD has been provided with copy of contract for site survey. I read the activity comment from permit desk asking that ACHD fee's, if any, be verified before permit is picked up. Dennis will check with ACHD and be in to pick up permit.
|
Print Occupancy Form | | | 6/27/2007 | | DONE |
|
|
|
|
Telephone call | | | 6/27/2007 | | DONE |
|
|
|
t/c w kristen haener at ###-#### - permit ready and fees given - also explained that she needed to contact ACHD and see if there were any fees that needed to be paid before coming to pick up this permit
|
Permit Ready to Issue | | | 6/27/2007 | | |
|
|
|
|
Routing - PLAN CHECK | 6/20/2007 | | 6/26/2007 | | PASS |
|
|
|
No resubmittals required. Plans to permit desk to issue.
|
Plan resubmittals received | | | 6/26/2007 | | |
|
|
|
Received 1 responce letter from JJDS Architects (3 pgs), 2 copies of sheets A1.0, A1.1, A2.0, A2.1, A2.2, A3.0, A4.0, A5.0, A5.1 and taken to Dan Stuart
|
Telephone call | | | 6/26/2007 | | DONE |
|
|
|
Call from Tad Jones saying he has turned in resubmittals on 6/25/07 wanting to know if I had them. I do not. Probably getting checked in at permit counter. Will begin 2nd review when received.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 6/26/2007 | | PASS |
|
|
|
|
Plan assigned to (DRS) | 5/22/2007 | | 6/26/2007 | | PASS |
|
|
|
6/26/2007 16:10:24 DRS - activity updated through activity BLDA022 from case BLD07-01185.
|
Routing - FIRE | 6/19/2007 | | 6/20/2007 | | PASS |
|
|
|
Attached IFC review comments to plans.
|
1st review completed | | | 6/20/2007 | | FAIL |
|
|
|
|
Plan resubmittals requested | | | 6/19/2007 | | DONE |
|
|
|
E-mail to Tad Jones at JJDS Architects.
|
Print Pending Permit.LaserJet4 | | | 6/19/2007 | | |
|
|
|
|
Routing - PLAN CHECK | 6/5/2007 | | 6/19/2007 | | FAIL |
|
|
|
Resubmittals required. copy of plan review e-mailed to architect for response & correction. Routing to fire code analyst.
|
Routing - PLANNING | 6/1/2007 | | 6/5/2007 | | PASS |
|
|
|
Cody Riddle CUP06-00122
|
Routing - PLUMBING | 5/24/2007 | | 6/1/2007 | | PASS |
|
|
|
SIZE WATER PER UPC 610. premis and thermol protection required. child sized toilets will be required. 120 deg. max. hot water to public lavs.
|
Routing - Erosion and Sediment | 5/23/2007 | | 5/24/2007 | | PASS |
|
|
|
No ESC permit required. per SWG and ADH.
|
Routing PW Street Lights | 5/22/2007 | | 5/23/2007 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS | 5/22/2007 | | 5/23/2007 | | PASS |
|
|
|
|
Pending Assignment by MYS | 5/22/2007 | | 5/22/2007 | | DONE |
|
|
|
5/22/2007 11:48:23 MYS - activity updated through activity BLDA168 from case BLD07-01185.
|
Recd Pcfee & Taken To Pln CK | | | 5/22/2007 | | DONE |
|
|
|
had to adj fees as there is a grading & drainage plan as well
|
Routing PW Sewer Rating | 5/22/2007 | | 5/22/2007 | | PASS |
|
|
|
|
Routing PW Drainage | 5/22/2007 | | 5/22/2007 | | PASS |
|
|
|
OK FOR TI ONLY
|
Application received | | | 5/10/2007 | | |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 5/10/2007 | | |
|
|
|
|