First Notice | | 7/26/2010 | 7/16/2010 | | DONE |
|
|
|
|
BLD-Aging Inspection | 6/30/2010 | 6/30/2010 | 7/1/2010 | | PASS |
Tony Young
|
|
|
|
DOC - Permit Finaled | 7/1/2010 | 7/1/2010 | 7/1/2010 | P | PASS |
Tony Young
|
|
|
|
BLD-Aging Inspection | 4/30/2010 | 4/30/2010 | 5/4/2010 | | PEND |
Tony Young
|
|
|
|
BLD-Final | 11/15/2007 | 11/15/2007 | 11/15/2007 | P | PASS |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 11/15/2007 at 9:50:25 AM. Contact: ###-####. directed contractor to PDS for l o c,, need to verify all fees are paid
|
FIRE-Final Inspection | 11/14/2007 | 11/15/2007 | 11/15/2007 | A | PASS |
Troy Cobbley
|
|
|
life safety passed.
|
FIRE-Final Inspection | 9/26/2007 | 9/27/2007 | 9/27/2007 | A | FAIL |
Troy Cobbley
|
|
|
No access into the space and ceiling tile is not installed.
|
FIRE-Final Inspection | 9/21/2007 | 9/21/2007 | 9/21/2007 | P | NR |
Forrest France
|
|
|
Need to final project related fire sprinkler permit, missing door hardware at the storage room, provide approved hardware at one door as discussed, missing ceiling tile needs to be installed.
|
BLD-Wall cover | 9/16/2007 | 9/17/2007 | 9/17/2007 | A | PART |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 9/16/2007 at 7:35:46 PM. Contact: ###-####. CMU wall at trash enclosure....OK pending MTI spec insp.
|
BLD-Framing/Rough-in | 9/10/2007 | 9/10/2007 | 9/10/2007 | P | PASS |
Tom Arcoraci
|
|
|
Scheduled by a contractor via Hello! on 9/10/2007 at 6:52:14 AM. Contact: ###-####. BATHROOM WALLS OK AND WALL NORTH OF IT OK
|
BLD-Foundation | 9/5/2007 | 9/6/2007 | 9/6/2007 | A | PART |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 9/5/2007 at 4:02:58 PM. Contact: ###-####. ftg and foundation wall ok pending S. I. report
|
Issue PAID IN FULL permit | | | 8/17/2007 | | |
|
|
|
|
Telephone call | | | 8/7/2007 | | DONE |
|
|
|
t/c w cindy huebert at ###-#### - permit ready and fees given - also need gc name, rce# and rp name
|
Permit Ready to Issue | | | 8/7/2007 | | DONE |
|
|
|
|
Routing - PUBLIC WORKS | 8/3/2007 | | 8/6/2007 | | PASS |
|
|
|
New Sheet SD1 & SD2 inserted into plans for response to PW solid waste plan failure. Routing for re-review.
|
Routing - PLAN CHECK | 8/6/2007 | | 8/6/2007 | | PASS |
|
|
|
|
Routing PW Solid Waste | 8/6/2007 | | 8/6/2007 | | PASS |
|
|
|
|
1st review completed | | | 8/6/2007 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/6/2007 | | DONE |
|
|
|
|
Routing - Erosion and Sediment | 8/6/2007 | | 8/6/2007 | | PASS |
|
|
|
Still needs RP
|
Inspection Record Card- Bld | | | 8/6/2007 | | DONE |
|
|
|
|
Plan assigned to (R_H) | 7/13/2007 | | 8/6/2007 | | PASS |
|
|
|
8/6/2007 14:39:43 RMH - activity updated through activity BLDA022 from case BLD07-01718.
|
Routing - PLAN CHECK | 7/23/2007 | | 8/3/2007 | | PEND |
|
|
|
Inserted resubmittals for PW into the original plans and routed back to public works for re-review per Marlene. Ron is on vacation until 8/13/07.
|
Telephone call | | | 8/3/2007 | | DONE |
|
|
|
Call from Cindy Huebert, BRS concerning the progress of these plans for review process. Resubmittals have been provided for PW.
|
Plan resubmittals received | | | 8/1/2007 | | |
|
|
|
received transmittal and three copies of pages SD-1, SD-2, BP1; taken to Ron Hill
|
Routing - PLANNING | 7/16/2007 | | 7/23/2007 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS | 7/13/2007 | | 7/16/2007 | | FAIL |
|
|
|
|
Routing PW Solid Waste | 7/13/2007 | | 7/16/2007 | | FAIL |
|
|
|
Enclosure is undersized. Gate clearance must be at least 11' for automated service, and gates must have a mechanism to hold them open and out of the way while container is being emptied.
|
Pending Assignment by MYS | 6/29/2007 | | 7/13/2007 | | DONE |
|
|
|
7/13/2007 06:49:25 RMH - activity updated through activity BLDA175 from case BLD07-01718.
|
Routing PW Sewer Rating | 7/13/2007 | | 7/13/2007 | | PASS |
|
|
|
|
Application received | | | 6/29/2007 | | |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 6/29/2007 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 6/29/2007 | | DONE |
|
|
|
|