Third Notice BLD | 10/30/2007 | 10/30/2007 | 12/19/2007 | | DONE |
|
|
|
Second Notice has not been responded to.
|
Second Notice BLD | 10/1/2007 | 10/1/2007 | 10/30/2007 | | DONE |
|
|
|
First Notice has not been responded to.
|
First Notice | | 9/7/2007 | 10/1/2007 | | DONE |
|
|
|
|
FIRE-Final Inspection | 9/7/2007 | 9/7/2007 | 9/7/2007 | A | PASS |
Troy Cobbley
|
|
|
life safety passed
|
BLD-Final | 9/7/2007 | 9/7/2007 | 9/7/2007 | A | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Internet Inspection Request from: John Lodman. ok for occ.
|
Permanent Occupancy UNPAID FEE | | | 9/7/2007 | | DONE |
|
|
|
|
FIRE-Final Inspection | 8/30/2007 | 8/31/2007 | 8/31/2007 | A | FAIL |
Troy Cobbley
|
|
|
Repair the exit signs and emergency light including the exit corridor at the restrooms.
|
BLD-Final | 8/30/2007 | 8/31/2007 | 8/31/2007 | A | CANC |
Jim Sly
|
|
|
Note that fire final was moved from yesterday at request of Fire Inspector. Please allow concurrent inspection if possible. Thank you. Canc by contractor...........
Phone #: ###-#### Internet Inspection Request from: John Lodman
|
FIRE-Final Inspection | 8/30/2007 | 8/30/2007 | 8/30/2007 | P | CANC |
Forrest France
|
|
|
Overbooked
|
BLD-Final | 8/30/2007 | 8/31/2007 | 8/30/2007 | A | CANC |
Mike Jordan
|
|
|
Please call 30 min prior if possible. Thank you. Phone #: ###-#### Internet Inspection Request from: John Lodman Inspection cancelled from web by: John Lodman
|
BLD-Wall cover | 8/6/2007 | 8/6/2007 | 8/6/2007 | P | PASS |
Mike Jordan
|
|
|
john Phone #: ###-####. All issues reolved.
|
BLD-Wall cover | 8/3/2007 | 8/6/2007 | 8/6/2007 | A | FAIL |
Mike Jordan
|
|
|
Mike- as discussed Friday, looking for okay to roll thru and change out ceiling tile, slatwall on existing walls and the 3 new display walls (no electrical in the 3 display walls). Thank you. Phone #: ###-#### Internet Inspection Request from: John Lodman. Needs to remove screws from top track to grid connections and support walls to structure above. c/n posted.
|
BLD-Framing/Rough-in | 8/2/2007 | 8/3/2007 | 8/3/2007 | P | NR |
Mike Jordan
|
|
|
john - wall cover Phone #: ###-####. elec. ri failed.
|
Telephone call | | | 8/1/2007 | | DONE |
|
|
|
t/c w john lodman at ###-#### - permit ready and fees given
|
Permit Ready to Issue | | | 8/1/2007 | | DONE |
|
|
|
|
Issue PAID IN FULL permit | | | 8/1/2007 | | DONE |
|
|
|
|
Plan assigned to (R_H) | 7/30/2007 | 7/30/2007 | 7/31/2007 | | PASS |
|
|
|
7/31/2007 08:52:34 RMH - activity updated through activity BLDA022 from case BLD07-01969.
|
Routing - PLAN CHECK | 7/31/2007 | | 7/31/2007 | | PASS |
|
|
|
|
Routing - FIRE | 7/31/2007 | | 7/31/2007 | | PASS |
|
|
|
MINOR WORK / Field Verify
|
Case Summary (BLD) | | | 7/31/2007 | | DONE |
|
|
|
|
1st review completed | | | 7/31/2007 | | |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/31/2007 | | DONE |
|
|
|
|
Print Occupancy Form | | | 7/31/2007 | | DONE |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 7/30/2007 | | DONE |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 7/30/2007 | | |
|
|
|
|
Application received | | | 7/27/2007 | | |
|
|
|
|