First Notice | | 7/2/2015 | 7/9/2015 | | DONE |
|
|
|
Mailed 7-10-15
|
Permanent Occupancy | | | 6/22/2015 | | DONE |
|
|
|
|
Third Notice BLD | 1/29/2009 | 1/29/2009 | 4/3/2009 | | DONE |
Alexandra L. DeYoung
|
|
|
Second Notice has not been responded to.
|
Second Notice BLD | 1/2/2009 | 1/2/2009 | 1/29/2009 | | DONE |
Cathy Brown
|
|
|
First Notice has not been responded to.
|
First Notice | 11/26/2008 | 11/26/2008 | 1/2/2009 | | DONE |
Tony Young
|
|
|
|
DOC - Permit Finaled | 11/26/2008 | 11/26/2008 | 11/26/2008 | P | PASS |
Tony Young
|
|
|
done
|
BLD-Final | 11/25/2008 | 11/26/2008 | 11/26/2008 | A | PASS |
Tony Young
|
|
|
dave Phone #: ###-#### final ok now
|
BLD-Final | 10/29/2008 | 10/29/2008 | 10/29/2008 | P | PART |
Tony Young
|
|
|
ward Phone #: ###-####, call 1/2 hr ahead of time tenp occ. ok,,, until zoning/c. e./ landscape is finaled, then ok for perm occ.
|
BLD-Final | 10/28/2008 | 10/29/2008 | 10/29/2008 | A | PART |
Tony Young
|
|
|
ward Phone #: ###-####, phone conf.. will come back in pm when someone is here
|
FIRE-Final Inspection | 9/24/2008 | 9/25/2008 | 9/25/2008 | A | PASS |
Troy Cobbley
|
|
|
Life safety passed
|
FIRE-Final Inspection | 9/10/2008 | 9/10/2008 | 9/10/2008 | P | FAIL |
Troy Cobbley
|
|
|
The exit signs and exit discharge lights have not been repaired.
|
FIRE-Final Inspection | 8/28/2008 | 8/28/2008 | 8/28/2008 | P | FAIL |
Troy Cobbley
|
|
|
Provide emergency lighting including exit discharge as discussed and repair the non-functional exit signs. Also disable the lock on the door between the lobby and the projector room
|
BLD-Foundation | 7/24/2008 | 7/25/2008 | 7/25/2008 | P | PASS |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 7/24/2008 at 2:30:47 PM. Contact: ###-####. stair ftgs
|
BLD-Framing/Rough-in | 5/7/2008 | 5/8/2008 | 5/8/2008 | A | PASS |
Mike Jordan
|
|
|
Scheduled by a contractor via Hello! on 5/7/2008 at 2:36:05 PM. Contact: ###-####. Interior framed walls in office area at mezz.
|
Issue PAID IN FULL permit | | | 3/17/2008 | | |
|
|
|
|
Routing - PLAN CHECK | 3/12/2008 | | 3/13/2008 | | DONE |
Carl Westfall
|
|
|
Done routing.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 3/13/2008 | | DONE |
|
|
|
|
Print Occupancy Form | | | 3/13/2008 | | |
|
|
|
|
Telephone call | | | 3/13/2008 | | DONE |
|
|
|
t/c w eric denning at ###-#### - permit ready and fees given
|
Permit Ready to Issue | | | 3/13/2008 | | DONE |
|
|
|
|
Plan assigned to (CJW) | 9/1/2007 | | 3/13/2008 | | PASS |
Carl Westfall
|
|
|
3/13/2008 08:26:06 CJW - activity updated through activity BLDA022 from case BLD07-02106.
|
Routing - PLAN CHECK | 10/23/2007 | | 3/12/2008 | | PASS |
Carl Westfall
|
|
|
Drawings approved after the resubmittal review.
|
Routing - PLANNING | 3/12/2008 | | 3/12/2008 | | PASS |
Cody Riddle
|
|
|
Change to stairway.
|
Routing - PUBLIC WORKS | 3/12/2008 | | 3/12/2008 | | DONE |
Louise Waldorf
|
|
|
Shower removed. Fees re-calculated.
|
Plan resubmittals received | | | 3/6/2008 | | |
Carl Westfall
|
|
|
received "2" sets of plans A O.O, A 2.O, A2.1, A2.2, A3.1, & A4.1--plans taken to Carl Westfall
|
Routing - FIRE | 10/18/2007 | | 10/23/2007 | | PASS |
|
|
|
Attached IFC review comments to plans.
|
1st review completed | | | 10/23/2007 | | FAIL |
|
|
|
|
Routing - PLAN CHECK | 9/6/2007 | | 10/18/2007 | | FAIL |
|
|
|
The IBC plan review was started on October 17, 2007 and was finished the next day. Revised drawings were required. See the plan review report.
|
Routing - Erosion and Sediment | 9/5/2007 | | 9/6/2007 | | PASS |
|
|
|
No ESC permit required.
|
Plan resubmittals received | | | 9/5/2007 | | |
|
|
|
received 1 transmittal, and 3 copys of sheet A0.0 taken to Carl W.
|
Routing - PLANNING | 9/4/2007 | | 9/5/2007 | | PASS |
|
|
|
Sarah Schafer CZC07-00182
|
Routing - PUBLIC WORKS | 9/4/2007 | | 9/4/2007 | | PASS |
|
|
|
|
Routing PW Sewer Rating | 9/4/2007 | | 9/4/2007 | | PASS |
|
|
|
|
Plan Reviewer's activity | | | 9/1/2007 | | DONE |
|
|
|
Sent e-mail to Trey Hoff (architect) as follows:
Trey,
I just began routing your building plans and application for the theater and noticed you did not have a site plan included with your construction documents. As you are adding exterior openings and the new enclosed exterior stair to the mezzanine we will need you to submit a site plan showing the location of this space in relationship to surrounding property lines, also the footprint of this tenant in relationship to the surrounding complex, and denote the type of construction. If you need to do research we do have the original plans on file which should assist you. Contact our records section on the 2nd floor here in City Hall and ask for Pam. The microfiche number is 940765 and the original project date was 12/88.
The building and fire plan reviewers will not be able to conduct their reviews without this information.--Thanks, Marlene
|
Pending Assignment by MYS | 8/10/2007 | | 9/1/2007 | | DONE |
|
|
|
9/1/2007 11:20:10 MYS - activity updated through activity BLDA172 from case BLD07-02106.
|
Plans ACCEPTED BY PLAN TECH | | | 8/13/2007 | | |
|
|
|
|
Application received | | | 8/10/2007 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 8/10/2007 | | DONE |
|
|
|
|
Zoning Approval | 11/24/2008 | 11/24/2008 | | | |
Sarah Schafer
|
|
|
|
Zoning Approval | 11/24/2008 | 11/24/2008 | | | PASS |
Sarah Schafer
|
|
|
The stairs, gate and openings were constructed per CZC07-00182.
|