Third Notice BLD | 9/22/2008 | 9/22/2008 | 11/21/2008 | | DONE |
Cathy Brown
|
|
|
Second Notice has not been responded to.
|
Second Notice BLD | 8/11/2008 | 8/11/2008 | 9/22/2008 | | DONE |
Cathy Brown
|
|
|
First Notice has not been responded to.
|
First Notice | | 6/12/2008 | 8/11/2008 | | DONE |
|
|
|
|
Permanent Occupancy UNPAID FEE | | | 6/12/2008 | | DONE |
Marsha Smylie
|
|
|
|
BLD-Final | 6/11/2008 | 6/11/2008 | 6/11/2008 | P | PART |
Jim Storey
|
|
|
Richard; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt final ok pending p&z sign off.
|
FIRE-Final Inspection | 6/10/2008 | 6/11/2008 | 6/11/2008 | A | PASS |
Forrest France
|
|
|
Correction notice items listed at the previous inspection verified for compliance, life safety finaled.
|
Code Occupancy Approval | | | 6/11/2008 | | DONE |
|
|
|
|
FIRE-Final Inspection | 5/20/2008 | 5/20/2008 | 5/20/2008 | P | FAIL |
Forrest France
|
|
|
Fire code review notes indicate the existing non-required fire suppression system if removed shall require a demo permit. Noted system has been deleted without issuance of a permit. Also need to provide a current inspection/certification tag for the fire extinguisher, remainder of life safety is satisfactory.
|
BLD-Conference | 5/6/2008 | 5/6/2008 | 5/6/2008 | P | PASS |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 5/6/2008 at 10:32:09 AM. Contact: ###-####.
|
FIRE-Final Inspection | 4/23/2008 | 4/23/2008 | 4/23/2008 | P | NR |
Forrest France
|
|
|
Project work is not completed for final life safety inspection at this time.
|
BLD-Framing/Rough-in | 3/19/2008 | 3/20/2008 | 3/20/2008 | A | PASS |
Jim Storey
|
|
|
jason \\ceiling Phone #: ###-#### ceilling ok need to check for spreader bars thur out at final.
|
BLD-Other | 1/18/2008 | 1/22/2008 | 1/22/2008 | A | PASS |
Jim Storey
|
|
|
jason Note: shear early as possible Phone #: ###-#### sheer pannels on south wall ok for cover.
|
BLD-Framing/Rough-in | 1/15/2008 | 1/16/2008 | 1/16/2008 | A | PASS |
Jim Storey
|
|
|
jason Phone #: ###-####
|
Issue PAID IN FULL permit | | | 11/30/2007 | | DONE |
|
|
|
|
Telephone call | | | 11/29/2007 | | DONE |
|
|
|
t/c w chad harbig at ###-#### - permit ready and fees given - also need gc name and rce#
|
Permit Ready to Issue | | | 11/29/2007 | | DONE |
|
|
|
|
Plan assigned to (CJW) | 10/16/2007 | | 11/28/2007 | | PASS |
|
|
|
11/28/2007 13:57:29 CJW - activity updated through activity BLDA022 from case BLD07-02583.
|
Routing - PLAN CHECK | 11/19/2007 | | 11/28/2007 | | PASS |
|
|
|
Drawings approved after resubmittal review.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 11/28/2007 | | DONE |
|
|
|
|
Print Occupancy Form | | | 11/28/2007 | | DONE |
|
|
|
|
Plan resubmittals received | | | 11/20/2007 | | |
|
|
|
received letter from cshqa & "2" sets of plans including each sheet of A2.O A2.1, A5.1, A7.1, M1.1, M2.1, M4.1, PO.1, P1.1, P1.2, & P2.1--plans taken to Carl Westfall
|
Routing - PLAN CHECK | 11/8/2007 | | 11/19/2007 | | FAIL |
|
|
|
Finished the resubmittal review. Three items not resolved. See the 2nd plan review report. E-mailed a copy to the Architect.
Carl Westfall ###-####
|
Plan resubmittals received | | | 11/15/2007 | | |
|
|
|
received 1 response,2 structural calcsand 2 copies of sheets A2.1,A4.1,A7.1,A9.1,M2.1 taken to Carl W.
|
Routing - FIRE | 11/7/2007 | | 11/8/2007 | | PASS |
|
|
|
Attached Fire code review comments to plans.
|
1st review completed | | | 11/8/2007 | | FAIL |
|
|
|
|
Routing - PLAN CHECK | 10/18/2007 | | 11/7/2007 | | FAIL |
|
|
|
The IBC plan review was started on November 5, 2007 and finished on November 7, 2007. Revised drawings were required. See the plan review report.
|
Routing - PLANNING | 10/16/2007 | | 10/18/2007 | | PASS |
|
|
|
Sarah Schafer CZC07-00254
Approved.
|
Routing - PUBLIC WORKS | 10/16/2007 | | 10/16/2007 | | PASS |
|
|
|
|
Pending Assignment by MYS | 10/1/2007 | | 10/16/2007 | | DONE |
|
|
|
10/16/2007 08:01:55 MYS - activity updated through activity BLDA172 from case BLD07-02583.
|
Routing PW Sewer Rating | 10/16/2007 | | 10/16/2007 | | PASS |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 10/1/2007 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 10/1/2007 | | |
|
|
|
|
Application received | | | 9/28/2007 | | |
|
|
|
|